Development of an optoelectronic device with control of luminous intensity via open loop for colorimetric analysis of coffee beans (Poster + Paper) (2025)
- Authors:
- USP affiliated authors: CASTRO NETO, JARBAS CAIADO DE - IFSC ; MONTALVAO, FELIPE FLORES - EESC ; OLIVEIRA, BRUNO PEREIRA DE - IFSC ; YASUOKA, FÁTIMA MARIA MITSUE - IFSC
- Unidades: IFSC; EESC
- DOI: 10.1117/12.3055070
- Subjects: CAFÉ; COLORIMETRIA; ANÁLISE SENSORIAL DE ALIMENTOS; SENSORES ÓPTICOS
- Keywords: Sensors; Statistical analysis; Control systems; RGB color model; Color; Light emitting diodes; Light sources and illumination; Telecommunications; LED lighting; Optoelectronic devices
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Publisher place: Bellingham
- Date published: 2025
- Source:
- Título: Proceedings of SPIE
- ISSN: 0277-786X
- Volume/Número/Paginação/Ano: v. 13357, p. 133570K-1-133570K-7, Jan. 2025
- Conference titles: LASE
- Este periódico é de acesso aberto
- Este artigo NÃO é de acesso aberto
-
ABNT
MONTALVÃO, Felipe Flores et al. Development of an optoelectronic device with control of luminous intensity via open loop for colorimetric analysis of coffee beans (Poster + Paper). Proceedings of SPIE. Bellingham: Instituto de Física de São Carlos, Universidade de São Paulo. Disponível em: https://doi.org/10.1117/12.3055070. Acesso em: 22 jan. 2026. , 2025 -
APA
Montalvão, F. F., Oliveira, B. P. de, Cruz, A. N., Yasuoka, F. M. M., & Castro Neto, J. C. de. (2025). Development of an optoelectronic device with control of luminous intensity via open loop for colorimetric analysis of coffee beans (Poster + Paper). Proceedings of SPIE. Bellingham: Instituto de Física de São Carlos, Universidade de São Paulo. doi:10.1117/12.3055070 -
NLM
Montalvão FF, Oliveira BP de, Cruz AN, Yasuoka FMM, Castro Neto JC de. Development of an optoelectronic device with control of luminous intensity via open loop for colorimetric analysis of coffee beans (Poster + Paper) [Internet]. Proceedings of SPIE. 2025 ; 13357( Ja 2025): 133570K-1-133570K-7.[citado 2026 jan. 22 ] Available from: https://doi.org/10.1117/12.3055070 -
Vancouver
Montalvão FF, Oliveira BP de, Cruz AN, Yasuoka FMM, Castro Neto JC de. Development of an optoelectronic device with control of luminous intensity via open loop for colorimetric analysis of coffee beans (Poster + Paper) [Internet]. Proceedings of SPIE. 2025 ; 13357( Ja 2025): 133570K-1-133570K-7.[citado 2026 jan. 22 ] Available from: https://doi.org/10.1117/12.3055070 - Aparelho para descontaminação de equipamentos e alimentos secos
- Desenvolvimento de um equipamento optoeletrônico com controle de intensidade luminosa via malha aberta para análise espectral de fluorescência de grãos de café
- Peltier-based temperature regulation: a method for performance optimization in solid-state lasers
- Método de bioimpressão por manufatura aditiva, composição e material biocompatível para uso em manufatura aditiva
- Low-coherence lock-in interferometer for ophthalmology
- Brewed coffee sensorial classification with fluorescence spectroscopy by chemometric analysis
- Fundamentação de conceitos de óptica e suas aplicações
- Processo óptico para a análise e seleção da qualidade de grãos de café
- Fibromialgia e inteligência artificial
- Kinetics with UVC irradiation using a continuous-flow system: mathematical fitting compared to microbiological analysis
Informações sobre o DOI: 10.1117/12.3055070 (Fonte: oaDOI API)
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| 3244805.pdf | Direct link |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas