Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra (2018)
- Authors:
- USP affiliated authors: VANIN, VITO ROBERTO - IF ; MAIDANA, NORA LIA - IF ; MARTINS, MARCOS NOGUEIRA - IF ; MALAFRONTE, ALEXANDRE ALMEIDA - IF
- Unidade: IF
- DOI: 10.1107/S1600577517018318
- Subjects: MÉTODO DE MONTE CARLO; ELÉTRONS; RAIOS X
- Language: Inglês
- Imprenta:
- Source:
- Título: Journal of Synchrotron Radiation
- Volume/Número/Paginação/Ano: v. 25, p. 484-495, mar. 2018
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
BARROS, Suelen Fernandes de et al. Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra. Journal of Synchrotron Radiation, v. 25, p. 484-495, 2018Tradução . . Disponível em: https://doi.org/10.1107/S1600577517018318. Acesso em: 10 jan. 2026. -
APA
Barros, S. F. de, Vanin, V. R., Maidana, N. L., Martins, M. N., & Malafronte, A. A. (2018). Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra. Journal of Synchrotron Radiation, 25, 484-495. doi:10.1107/S1600577517018318 -
NLM
Barros SF de, Vanin VR, Maidana NL, Martins MN, Malafronte AA. Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra [Internet]. Journal of Synchrotron Radiation. 2018 ; 25 484-495.[citado 2026 jan. 10 ] Available from: https://doi.org/10.1107/S1600577517018318 -
Vancouver
Barros SF de, Vanin VR, Maidana NL, Martins MN, Malafronte AA. Energy-dependent dead-time correction in digital pulse processors applied to silicon drift detector's X-ray spectra [Internet]. Journal of Synchrotron Radiation. 2018 ; 25 484-495.[citado 2026 jan. 10 ] Available from: https://doi.org/10.1107/S1600577517018318 - Measurement of doubly differential electron bremsstrahlung cross sections at the end point (tip) for 'C', 'AL', 'TE', 'TA' and 'AU'
- First experiments with the IFUSP microtron injector
- Monte Carlo simulation of nuclear resonance fluorescence setup at IFUSP: MCNPX and GEANT simulations results (I)
- 'AG' 'K'-shell ionization by electron impact: new cross-section measurements between 50 and 100 keV and review of previous experimental data
- The 10-100 keV beam line of the Sao Paulo microtron electron accelerator
- Análise da infuência do desalinhamento de uma lente quadrupolar em um feixe de elétrons
- Cross sections of K-shell ionization by electron impact, measured from threshold to 100 keV, for 'AU' and 'BI'
- Atomic and radiation physics with the são paulo microtron: from inflation to dark energy
- Ionization cross sections of the 'AU' L subshells by electron impact from the 'L IND. 3' threshold to 100 keV
- Efficiency calibration of x-ray 'H''P''GE' detectors for photons with energies above the 'GE' 'K' binding energy
Informações sobre o DOI: 10.1107/S1600577517018318 (Fonte: oaDOI API)
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| S1600577517018318.pdf | Direct link | ||
| ve5075sup1.pdf |
How to cite