Filtros : "VOLTAMETRIA" "COBRE" Removido: "FCF-FBF" Limpar

Filtros



Refine with date range


  • Source: Electroanalysis. Unidades: IFSC, EESC

    Subjects: NANOPARTÍCULAS, COBRE, VOLTAMETRIA

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MARALDI, Vitor Alexandre et al. Graphene oxide as a platform for copper pentacyanonitrosylferrate nanoparticles and their behavior in the electro-oxidation of N-acetylcysteine. Electroanalysis, v. 32, n. 7, p. 1408-1416, 2020Tradução . . Disponível em: https://doi.org/10.1002/elan.201900493. Acesso em: 20 out. 2024.
    • APA

      Maraldi, V. A., Calderon, Y. N. C., Barbosa, P. F. P., Mastelaro, V. R., & Carmo, D. R. do. (2020). Graphene oxide as a platform for copper pentacyanonitrosylferrate nanoparticles and their behavior in the electro-oxidation of N-acetylcysteine. Electroanalysis, 32( 7), 1408-1416. doi:10.1002/elan.201900493
    • NLM

      Maraldi VA, Calderon YNC, Barbosa PFP, Mastelaro VR, Carmo DR do. Graphene oxide as a platform for copper pentacyanonitrosylferrate nanoparticles and their behavior in the electro-oxidation of N-acetylcysteine [Internet]. Electroanalysis. 2020 ; 32( 7): 1408-1416.[citado 2024 out. 20 ] Available from: https://doi.org/10.1002/elan.201900493
    • Vancouver

      Maraldi VA, Calderon YNC, Barbosa PFP, Mastelaro VR, Carmo DR do. Graphene oxide as a platform for copper pentacyanonitrosylferrate nanoparticles and their behavior in the electro-oxidation of N-acetylcysteine [Internet]. Electroanalysis. 2020 ; 32( 7): 1408-1416.[citado 2024 out. 20 ] Available from: https://doi.org/10.1002/elan.201900493
  • Source: Resumos. Conference titles: Reunião Anual da Sociedade Brasileira de Química/SBQ. Unidade: IQ

    Subjects: NANOPARTÍCULAS, COBRE, VOLTAMETRIA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      PASTRIÁN, Fabián Andee Cerda et al. Nanopartículas de oxido de cobre (I) de tamanho e geometria controlada, para a construção de sensores não enzimáticos. 2015, Anais.. São Paulo: Sociedade Brasileira de Química/SBQ, 2015. Disponível em: http://www.adaltech.com.br/testes/sbq2015/resumos/T1215-1.pdf. Acesso em: 20 out. 2024.
    • APA

      Pastrián, F. A. C., Silva, A. G. M. da, Camargo, P. H. C. de, & Torresi, S. I. C. de. (2015). Nanopartículas de oxido de cobre (I) de tamanho e geometria controlada, para a construção de sensores não enzimáticos. In Resumos. São Paulo: Sociedade Brasileira de Química/SBQ. Recuperado de http://www.adaltech.com.br/testes/sbq2015/resumos/T1215-1.pdf
    • NLM

      Pastrián FAC, Silva AGM da, Camargo PHC de, Torresi SIC de. Nanopartículas de oxido de cobre (I) de tamanho e geometria controlada, para a construção de sensores não enzimáticos [Internet]. Resumos. 2015 ;[citado 2024 out. 20 ] Available from: http://www.adaltech.com.br/testes/sbq2015/resumos/T1215-1.pdf
    • Vancouver

      Pastrián FAC, Silva AGM da, Camargo PHC de, Torresi SIC de. Nanopartículas de oxido de cobre (I) de tamanho e geometria controlada, para a construção de sensores não enzimáticos [Internet]. Resumos. 2015 ;[citado 2024 out. 20 ] Available from: http://www.adaltech.com.br/testes/sbq2015/resumos/T1215-1.pdf
  • Source: Journal of Biological Inorganic Chemistry. Conference titles: European Biological Inorganic Chemistry Conference. Unidades: IQ, FM

    Subjects: COBRE, VOLTAMETRIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ESCRIBANO, Esther et al. Synthesis, characterization and cytotoxicity assays of novel binuclear Cu(II)-Pt(II), and correlated mononuclear copper(II) complexes with oxindolimine ligands. Journal of Biological Inorganic Chemistry. New York: Instituto de Química, Universidade de São Paulo. . Acesso em: 20 out. 2024. , 2014
    • APA

      Escribano, E., Matias, T. A., Araki, K., Luz, C. P., Marques, F. L. N., & Ferreira, A. M. da C. (2014). Synthesis, characterization and cytotoxicity assays of novel binuclear Cu(II)-Pt(II), and correlated mononuclear copper(II) complexes with oxindolimine ligands. Journal of Biological Inorganic Chemistry. New York: Instituto de Química, Universidade de São Paulo.
    • NLM

      Escribano E, Matias TA, Araki K, Luz CP, Marques FLN, Ferreira AM da C. Synthesis, characterization and cytotoxicity assays of novel binuclear Cu(II)-Pt(II), and correlated mononuclear copper(II) complexes with oxindolimine ligands. Journal of Biological Inorganic Chemistry. 2014 ; 19( 2): S783 res. P31.[citado 2024 out. 20 ]
    • Vancouver

      Escribano E, Matias TA, Araki K, Luz CP, Marques FLN, Ferreira AM da C. Synthesis, characterization and cytotoxicity assays of novel binuclear Cu(II)-Pt(II), and correlated mononuclear copper(II) complexes with oxindolimine ligands. Journal of Biological Inorganic Chemistry. 2014 ; 19( 2): S783 res. P31.[citado 2024 out. 20 ]
  • Source: Sensors and Actuators B: Chemical. Unidade: IQ

    Subjects: NITRATOS, VOLTAMETRIA, COBRE

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SILVA, Iranaldo Santos da et al. Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables. Sensors and Actuators B: Chemical, v. 188, p. 94-98, 2013Tradução . . Disponível em: https://doi.org/10.1016/j.snb.2013.06.094. Acesso em: 20 out. 2024.
    • APA

      Silva, I. S. da, Araujo, W. R. de, Paixão, T. R. L. C. da, & Angnes, L. (2013). Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables. Sensors and Actuators B: Chemical, 188, 94-98. doi:10.1016/j.snb.2013.06.094
    • NLM

      Silva IS da, Araujo WR de, Paixão TRLC da, Angnes L. Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables [Internet]. Sensors and Actuators B: Chemical. 2013 ; 188 94-98.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.snb.2013.06.094
    • Vancouver

      Silva IS da, Araujo WR de, Paixão TRLC da, Angnes L. Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables [Internet]. Sensors and Actuators B: Chemical. 2013 ; 188 94-98.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.snb.2013.06.094
  • Source: Journal of Brazilian Chemical Society. Unidade: FFCLRP

    Subjects: COBRE, CARBONO, VOLTAMETRIA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      TAVARES, Elisângela de F. L. et al. An alternative method for the simultaneous determination of copper and lead for quality control of sugar cane spirit using a nanotube-based sensor. Journal of Brazilian Chemical Society, v. 23, n. 9, p. 1614-1622, 2012Tradução . . Disponível em: https://doi.org/10.1590/S0103-50532012005000024. Acesso em: 20 out. 2024.
    • APA

      Tavares, E. de F. L., Okumura, L. L., Cardoso, M. das G., Oliveira, M. F. de, Magriotis, Z. M., & Saczk, A. A. (2012). An alternative method for the simultaneous determination of copper and lead for quality control of sugar cane spirit using a nanotube-based sensor. Journal of Brazilian Chemical Society, 23( 9), 1614-1622. doi:10.1590/S0103-50532012005000024
    • NLM

      Tavares E de FL, Okumura LL, Cardoso M das G, Oliveira MF de, Magriotis ZM, Saczk AA. An alternative method for the simultaneous determination of copper and lead for quality control of sugar cane spirit using a nanotube-based sensor [Internet]. Journal of Brazilian Chemical Society. 2012 ; 23( 9): 1614-1622.[citado 2024 out. 20 ] Available from: https://doi.org/10.1590/S0103-50532012005000024
    • Vancouver

      Tavares E de FL, Okumura LL, Cardoso M das G, Oliveira MF de, Magriotis ZM, Saczk AA. An alternative method for the simultaneous determination of copper and lead for quality control of sugar cane spirit using a nanotube-based sensor [Internet]. Journal of Brazilian Chemical Society. 2012 ; 23( 9): 1614-1622.[citado 2024 out. 20 ] Available from: https://doi.org/10.1590/S0103-50532012005000024
  • Source: Resumos. Conference titles: Encontro Nacional de Química Analítica - ENQA. Unidade: IQ

    Subjects: VOLTAMETRIA, ÍONS, COBRE

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      FRIEDRICH, Leidi Cecilia et al. Estudo voltamétrico da interferência de íons cobre (II) e zinco (II) na reação de Fenton. 2011, Anais.. São Paulo: Instituto de Química/USP - Divisão de Química Analítica (DQA)/Sociedade Brasileira de Química (SBQ), 2011. . Acesso em: 20 out. 2024.
    • APA

      Friedrich, L. C., Mendes, M. A., Silva, V. de O., Zanta, C. L. de P. e S., Machulek Junior, A., & Quina, F. H. (2011). Estudo voltamétrico da interferência de íons cobre (II) e zinco (II) na reação de Fenton. In Resumos. São Paulo: Instituto de Química/USP - Divisão de Química Analítica (DQA)/Sociedade Brasileira de Química (SBQ).
    • NLM

      Friedrich LC, Mendes MA, Silva V de O, Zanta CL de P e S, Machulek Junior A, Quina FH. Estudo voltamétrico da interferência de íons cobre (II) e zinco (II) na reação de Fenton. Resumos. 2011 ;[citado 2024 out. 20 ]
    • Vancouver

      Friedrich LC, Mendes MA, Silva V de O, Zanta CL de P e S, Machulek Junior A, Quina FH. Estudo voltamétrico da interferência de íons cobre (II) e zinco (II) na reação de Fenton. Resumos. 2011 ;[citado 2024 out. 20 ]
  • Source: Talanta. Unidade: IQ

    Subjects: COBRE, VOLTAMETRIA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SOUZA, Ana Paula Ruas de et al. The use of a gold disc microelectrode for the determination of copper in human sweat. Talanta, v. 83, n. 1, p. 167-170, 2010Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2010.09.001. Acesso em: 20 out. 2024.
    • APA

      Souza, A. P. R. de, Lima, A. S., Salles, M. O., Nascimento, A. N. do, & Bertotti, M. (2010). The use of a gold disc microelectrode for the determination of copper in human sweat. Talanta, 83( 1), 167-170. doi:10.1016/j.talanta.2010.09.001
    • NLM

      Souza APR de, Lima AS, Salles MO, Nascimento AN do, Bertotti M. The use of a gold disc microelectrode for the determination of copper in human sweat [Internet]. Talanta. 2010 ; 83( 1): 167-170.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.talanta.2010.09.001
    • Vancouver

      Souza APR de, Lima AS, Salles MO, Nascimento AN do, Bertotti M. The use of a gold disc microelectrode for the determination of copper in human sweat [Internet]. Talanta. 2010 ; 83( 1): 167-170.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.talanta.2010.09.001
  • Source: Talanta. Unidade: IQ

    Subjects: COBRE, VOLTAMETRIA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MUNÕZ, Rodrigo Alejandro Abarza e OLIVEIRA, Pedro Vitoriano de e ANGNES, Lúcio. Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of 'CU' and 'PB' in lubricating oils. Talanta, v. 68, n. 3, p. 850-856, 2006Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2005.06.016. Acesso em: 20 out. 2024.
    • APA

      Munõz, R. A. A., Oliveira, P. V. de, & Angnes, L. (2006). Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of 'CU' and 'PB' in lubricating oils. Talanta, 68( 3), 850-856. doi:10.1016/j.talanta.2005.06.016
    • NLM

      Munõz RAA, Oliveira PV de, Angnes L. Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of 'CU' and 'PB' in lubricating oils [Internet]. Talanta. 2006 ; 68( 3): 850-856.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.talanta.2005.06.016
    • Vancouver

      Munõz RAA, Oliveira PV de, Angnes L. Combination of ultrasonic extraction and stripping analysis: an effective and reliable way for the determination of 'CU' and 'PB' in lubricating oils [Internet]. Talanta. 2006 ; 68( 3): 850-856.[citado 2024 out. 20 ] Available from: https://doi.org/10.1016/j.talanta.2005.06.016
  • Source: Resumos. Conference titles: Simpósio Brasileiro de Eletroquímica e Eletroanalítica. Unidade: IQ

    Subjects: COBRE, ELETRODO, NITRATOS, ÁGUA MINERAL, SALSICHA, VOLTAMETRIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      PAIXÃO, Thiago Regis Longo Cesar da e CARDOSO, Juliana Lopes e BERTOTTI, Mauro. Desenvolvimento de método analítico para quantificação de nitrato utilizando eletrodo de cobre modificado "In sutu". 2005, Anais.. Londrina: UEL, 2005. . Acesso em: 20 out. 2024.
    • APA

      Paixão, T. R. L. C. da, Cardoso, J. L., & Bertotti, M. (2005). Desenvolvimento de método analítico para quantificação de nitrato utilizando eletrodo de cobre modificado "In sutu". In Resumos. Londrina: UEL.
    • NLM

      Paixão TRLC da, Cardoso JL, Bertotti M. Desenvolvimento de método analítico para quantificação de nitrato utilizando eletrodo de cobre modificado "In sutu". Resumos. 2005 ;[citado 2024 out. 20 ]
    • Vancouver

      Paixão TRLC da, Cardoso JL, Bertotti M. Desenvolvimento de método analítico para quantificação de nitrato utilizando eletrodo de cobre modificado "In sutu". Resumos. 2005 ;[citado 2024 out. 20 ]
  • Source: Electroanalysis. Unidade: IQ

    Subjects: ELETRODO, QUÍMICA ANALÍTICA, COBRE, VOLTAMETRIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      RICHTER, Eduardo Mathias e PEDROTTI, Jairo José e ANGNES, Lúcio. Square-wave quantification of lead in rainwater with disposable gold electrodes without removal of dissolved oxygen. Electroanalysis, v. 15, n. 23-24, p. 1871-1877, 2003Tradução . . Acesso em: 20 out. 2024.
    • APA

      Richter, E. M., Pedrotti, J. J., & Angnes, L. (2003). Square-wave quantification of lead in rainwater with disposable gold electrodes without removal of dissolved oxygen. Electroanalysis, 15( 23-24), 1871-1877.
    • NLM

      Richter EM, Pedrotti JJ, Angnes L. Square-wave quantification of lead in rainwater with disposable gold electrodes without removal of dissolved oxygen. Electroanalysis. 2003 ; 15( 23-24): 1871-1877.[citado 2024 out. 20 ]
    • Vancouver

      Richter EM, Pedrotti JJ, Angnes L. Square-wave quantification of lead in rainwater with disposable gold electrodes without removal of dissolved oxygen. Electroanalysis. 2003 ; 15( 23-24): 1871-1877.[citado 2024 out. 20 ]

Digital Library of Intellectual Production of Universidade de São Paulo     2012 - 2024