Filtros : "BIOENGENHARIA" "EESC" Removido: "2005" Limpar

Filtros



Refine with date range


  • Source: Journal of Applied Polymer Science. Unidades: EESC, IQSC

    Subjects: BIOENGENHARIA, BIOMATERIAIS, FILMES FINOS, QUEIMADURAS

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTOS, Francisco Vieira dos e YOSHIOKA, Sergio Akinobu e BRANCIFORTI, Márcia Cristina. Large-area thin films of silk fibroin prepared by two methods with formic acid as solvent and glycerol as plasticizer. Journal of Applied Polymer Science, v. 138, n. 31, 2021Tradução . . Disponível em: https://doi.org/10.1002/app.50759. Acesso em: 16 set. 2024.
    • APA

      Santos, F. V. dos, Yoshioka, S. A., & Branciforti, M. C. (2021). Large-area thin films of silk fibroin prepared by two methods with formic acid as solvent and glycerol as plasticizer. Journal of Applied Polymer Science, 138( 31). doi:10.1002/app.50759
    • NLM

      Santos FV dos, Yoshioka SA, Branciforti MC. Large-area thin films of silk fibroin prepared by two methods with formic acid as solvent and glycerol as plasticizer [Internet]. Journal of Applied Polymer Science. 2021 ; 138( 31):[citado 2024 set. 16 ] Available from: https://doi.org/10.1002/app.50759
    • Vancouver

      Santos FV dos, Yoshioka SA, Branciforti MC. Large-area thin films of silk fibroin prepared by two methods with formic acid as solvent and glycerol as plasticizer [Internet]. Journal of Applied Polymer Science. 2021 ; 138( 31):[citado 2024 set. 16 ] Available from: https://doi.org/10.1002/app.50759
  • Unidade: EESC

    Subjects: ARTICULAÇÕES, PRÓTESE PARCIAL FIXA, BIOMECÂNICA, BIOENGENHARIA

    Versão PublicadaAcesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      CAURIN, Glauco Augusto de Paula e GIORIA, Gustavo dos Santos. Articulação de dois graus de liberdade para próteses. . Rio de Janeiro: Instituto Nacional da Propriedade Industrial. Disponível em: https://repositorio.usp.br/item/003080745. Acesso em: 16 set. 2024. , 2020
    • APA

      Caurin, G. A. de P., & Gioria, G. dos S. (2020). Articulação de dois graus de liberdade para próteses. Rio de Janeiro: Instituto Nacional da Propriedade Industrial. Recuperado de https://repositorio.usp.br/item/003080745
    • NLM

      Caurin GA de P, Gioria G dos S. Articulação de dois graus de liberdade para próteses [Internet]. 2020 ;[citado 2024 set. 16 ] Available from: https://repositorio.usp.br/item/003080745
    • Vancouver

      Caurin GA de P, Gioria G dos S. Articulação de dois graus de liberdade para próteses [Internet]. 2020 ;[citado 2024 set. 16 ] Available from: https://repositorio.usp.br/item/003080745
  • Source: Sustainability. Unidade: EESC

    Subjects: EROSÃO, BIOENGENHARIA, GEOTECNIA

    Versão PublicadaAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      VIANNA, Vinicius F. et al. Bioengineering techniques adopted for controlling riverbanks’ superficial erosion of the simplício hydroelectric power plant, Brazil. Sustainability, v. 12, n. 19, p. 1-20, 2020Tradução . . Disponível em: https://doi.org/10.3390/su12197886. Acesso em: 16 set. 2024.
    • APA

      Vianna, V. F., Fleury, M. P., Menezes, G. B. de, Coelho, A. T., Bueno, C., Silva, J. L. da, & Luz, M. P. da. (2020). Bioengineering techniques adopted for controlling riverbanks’ superficial erosion of the simplício hydroelectric power plant, Brazil. Sustainability, 12( 19), 1-20. doi:10.3390/su12197886
    • NLM

      Vianna VF, Fleury MP, Menezes GB de, Coelho AT, Bueno C, Silva JL da, Luz MP da. Bioengineering techniques adopted for controlling riverbanks’ superficial erosion of the simplício hydroelectric power plant, Brazil [Internet]. Sustainability. 2020 ; 12( 19): 1-20.[citado 2024 set. 16 ] Available from: https://doi.org/10.3390/su12197886
    • Vancouver

      Vianna VF, Fleury MP, Menezes GB de, Coelho AT, Bueno C, Silva JL da, Luz MP da. Bioengineering techniques adopted for controlling riverbanks’ superficial erosion of the simplício hydroelectric power plant, Brazil [Internet]. Sustainability. 2020 ; 12( 19): 1-20.[citado 2024 set. 16 ] Available from: https://doi.org/10.3390/su12197886
  • Source: Proceedings. Conference titles: PhotonIcs & Electromagnetics Research Symposium — Spring (PIERS — SPRING). Unidade: EESC

    Subjects: ENGENHARIA ELÉTRICA, FEIXES ÓPTICOS, COMUNICAÇÕES OPTO-ELETRÔNICAS, BIOENGENHARIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      CANDIDO, Paulo H. V. et al. Semantic web-based system for light scattering using the generalized Lorenz-Mie theory. 2019, Anais.. Rome, Italy: Escola de Engenharia de São Carlos, Universidade de São Paulo, 2019. . Acesso em: 16 set. 2024.
    • APA

      Candido, P. H. V., Santos, C. H. da S., Votto, L. F. M., & Ambrosio, L. A. (2019). Semantic web-based system for light scattering using the generalized Lorenz-Mie theory. In Proceedings. Rome, Italy: Escola de Engenharia de São Carlos, Universidade de São Paulo.
    • NLM

      Candido PHV, Santos CH da S, Votto LFM, Ambrosio LA. Semantic web-based system for light scattering using the generalized Lorenz-Mie theory. Proceedings. 2019 ;[citado 2024 set. 16 ]
    • Vancouver

      Candido PHV, Santos CH da S, Votto LFM, Ambrosio LA. Semantic web-based system for light scattering using the generalized Lorenz-Mie theory. Proceedings. 2019 ;[citado 2024 set. 16 ]
  • Source: Proceedings. Conference titles: SBFoton International Optics and Photonics Conference. Unidade: EESC

    Subjects: FOTÔNICA, BIOENGENHARIA, SENSOR, ENGENHARIA ELÉTRICA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SOARES, Rodrigo Romão França e MARTINS, Emiliano Rezende. Systematic comparison between photonic sensors based on dielectrics and metals. 2019, Anais.. Campinas, SP: SBFoton, 2019. . Acesso em: 16 set. 2024.
    • APA

      Soares, R. R. F., & Martins, E. R. (2019). Systematic comparison between photonic sensors based on dielectrics and metals. In Proceedings. Campinas, SP: SBFoton.
    • NLM

      Soares RRF, Martins ER. Systematic comparison between photonic sensors based on dielectrics and metals. Proceedings. 2019 ;[citado 2024 set. 16 ]
    • Vancouver

      Soares RRF, Martins ER. Systematic comparison between photonic sensors based on dielectrics and metals. Proceedings. 2019 ;[citado 2024 set. 16 ]
  • Unidade: EESC

    Subjects: BIOENGENHARIA, HEMODINÂMICA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      LOPES JÚNIOR, Guilherme Barbosa. Metodologia para análise computacional de escoamento sanguíneo em dispositivos de assistência ventricular. 2016. Tese (Doutorado) – Universidade de São Paulo, São Carlos, 2016. Disponível em: http://www.teses.usp.br/teses/disponiveis/18/18147/tde-21072016-092253/. Acesso em: 16 set. 2024.
    • APA

      Lopes Júnior, G. B. (2016). Metodologia para análise computacional de escoamento sanguíneo em dispositivos de assistência ventricular (Tese (Doutorado). Universidade de São Paulo, São Carlos. Recuperado de http://www.teses.usp.br/teses/disponiveis/18/18147/tde-21072016-092253/
    • NLM

      Lopes Júnior GB. Metodologia para análise computacional de escoamento sanguíneo em dispositivos de assistência ventricular [Internet]. 2016 ;[citado 2024 set. 16 ] Available from: http://www.teses.usp.br/teses/disponiveis/18/18147/tde-21072016-092253/
    • Vancouver

      Lopes Júnior GB. Metodologia para análise computacional de escoamento sanguíneo em dispositivos de assistência ventricular [Internet]. 2016 ;[citado 2024 set. 16 ] Available from: http://www.teses.usp.br/teses/disponiveis/18/18147/tde-21072016-092253/
  • Source: Communications in Computer and Information Science. Conference titles: International Joint Conference - BIOSTEC. Unidade: EESC

    Subjects: BIOENGENHARIA, SENSIBILIDADE CUTÂNEA, TRAUMATISMOS DA MEDULA ESPINHAL

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      VAROTO, Renato et al. Development and application of a portable device for cutaneous thermal sensitivity assessment: characterizing the neurophatic pain following spinal cord injury. Communications in Computer and Information Science. Heidelberg, Germany: Springer-Verlag. Disponível em: https://doi.org/10.1007/978-3-662-44485-6. Acesso em: 16 set. 2024. , 2014
    • APA

      Varoto, R., Hirono, F. C., Zorzenoni, F. O., Kido, R. Y. Z., Barcellos, W., & Cliquet Junior, A. (2014). Development and application of a portable device for cutaneous thermal sensitivity assessment: characterizing the neurophatic pain following spinal cord injury. Communications in Computer and Information Science. Heidelberg, Germany: Springer-Verlag. doi:10.1007/978-3-662-44485-6
    • NLM

      Varoto R, Hirono FC, Zorzenoni FO, Kido RYZ, Barcellos W, Cliquet Junior A. Development and application of a portable device for cutaneous thermal sensitivity assessment: characterizing the neurophatic pain following spinal cord injury [Internet]. Communications in Computer and Information Science. 2014 ; 452 41-53.[citado 2024 set. 16 ] Available from: https://doi.org/10.1007/978-3-662-44485-6
    • Vancouver

      Varoto R, Hirono FC, Zorzenoni FO, Kido RYZ, Barcellos W, Cliquet Junior A. Development and application of a portable device for cutaneous thermal sensitivity assessment: characterizing the neurophatic pain following spinal cord injury [Internet]. Communications in Computer and Information Science. 2014 ; 452 41-53.[citado 2024 set. 16 ] Available from: https://doi.org/10.1007/978-3-662-44485-6
  • Conference titles: Simpósio Internacional de Iniciação Científica e Tecnológica da Universidade de São Paulo - SIICUSP. Unidade: EESC

    Subjects: BIOMECÂNICA, BIOENGENHARIA, MÉTODO DOS ELEMENTOS FINITOS, ENGENHARIA MECÂNICA

    Versão PublicadaHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTOS, Luiz Eduardo Frezzatto e MATTAZIO, Rafael Rocha e SILVEIRA, Zilda de Castro. Avaliação estrutural de fêmur humano utilizando processamento de imagem médica, BioCAD e o método dos elementos finitos. 2014, Anais.. São Paulo, SP: Pró-Reitoria de Pesquisa/USP, 2014. Disponível em: https://repositorio.usp.br/directbitstream/a6bb62e9-59f4-4754-a51b-0dafeb7ede9f/OK___resumo%2011%20-%20Avalia%C3%A7%C3%A3o%20estrutural%20de%20f%C3%AAmur%20humano%20utilizando%20processamento%20de%20imagem%20m%C3%A9dica%2C%20BioCAD%20e%20o%20m%C3%A9todo%20dos%20elementos%20finitos.pdf. Acesso em: 16 set. 2024.
    • APA

      Santos, L. E. F., Mattazio, R. R., & Silveira, Z. de C. (2014). Avaliação estrutural de fêmur humano utilizando processamento de imagem médica, BioCAD e o método dos elementos finitos. In . São Paulo, SP: Pró-Reitoria de Pesquisa/USP. Recuperado de https://repositorio.usp.br/directbitstream/a6bb62e9-59f4-4754-a51b-0dafeb7ede9f/OK___resumo%2011%20-%20Avalia%C3%A7%C3%A3o%20estrutural%20de%20f%C3%AAmur%20humano%20utilizando%20processamento%20de%20imagem%20m%C3%A9dica%2C%20BioCAD%20e%20o%20m%C3%A9todo%20dos%20elementos%20finitos.pdf
    • NLM

      Santos LEF, Mattazio RR, Silveira Z de C. Avaliação estrutural de fêmur humano utilizando processamento de imagem médica, BioCAD e o método dos elementos finitos [Internet]. 2014 ;[citado 2024 set. 16 ] Available from: https://repositorio.usp.br/directbitstream/a6bb62e9-59f4-4754-a51b-0dafeb7ede9f/OK___resumo%2011%20-%20Avalia%C3%A7%C3%A3o%20estrutural%20de%20f%C3%AAmur%20humano%20utilizando%20processamento%20de%20imagem%20m%C3%A9dica%2C%20BioCAD%20e%20o%20m%C3%A9todo%20dos%20elementos%20finitos.pdf
    • Vancouver

      Santos LEF, Mattazio RR, Silveira Z de C. Avaliação estrutural de fêmur humano utilizando processamento de imagem médica, BioCAD e o método dos elementos finitos [Internet]. 2014 ;[citado 2024 set. 16 ] Available from: https://repositorio.usp.br/directbitstream/a6bb62e9-59f4-4754-a51b-0dafeb7ede9f/OK___resumo%2011%20-%20Avalia%C3%A7%C3%A3o%20estrutural%20de%20f%C3%AAmur%20humano%20utilizando%20processamento%20de%20imagem%20m%C3%A9dica%2C%20BioCAD%20e%20o%20m%C3%A9todo%20dos%20elementos%20finitos.pdf
  • Source: Journal of Applied Mechanics. Unidade: EESC

    Subjects: OSSO E OSSOS (ESTRUTURA), HOMOGENEIZAÇÃO, PIEZOELETRICIDADE, BIOENGENHARIA

    Acesso à fonteAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      AGUIAR, Adair Roberto et al. Effective electromechanical properties of 622 piezoelectric medium with unidirectional cylindrical holes. Journal of Applied Mechanics, v. 80, n. 5, p. 050905-1 - 050905-11, 2013Tradução . . Disponível em: https://doi.org/10.1115/1.4023475. Acesso em: 16 set. 2024.
    • APA

      Aguiar, A. R., Bravo Castillero, J., Rodríguez Ramos, R., & Silva, U. P. da. (2013). Effective electromechanical properties of 622 piezoelectric medium with unidirectional cylindrical holes. Journal of Applied Mechanics, 80( 5), 050905-1 - 050905-11. doi:10.1115/1.4023475
    • NLM

      Aguiar AR, Bravo Castillero J, Rodríguez Ramos R, Silva UP da. Effective electromechanical properties of 622 piezoelectric medium with unidirectional cylindrical holes [Internet]. Journal of Applied Mechanics. 2013 ; 80( 5): 050905-1 - 050905-11.[citado 2024 set. 16 ] Available from: https://doi.org/10.1115/1.4023475
    • Vancouver

      Aguiar AR, Bravo Castillero J, Rodríguez Ramos R, Silva UP da. Effective electromechanical properties of 622 piezoelectric medium with unidirectional cylindrical holes [Internet]. Journal of Applied Mechanics. 2013 ; 80( 5): 050905-1 - 050905-11.[citado 2024 set. 16 ] Available from: https://doi.org/10.1115/1.4023475
  • Source: Proceedings. Conference titles: International Conference on Biomedical Electronics and Devices -BIODEVICES. Unidades: EESC, BIOENGENHARIA, IQSC

    Subjects: BIOENGENHARIA, TRAUMATISMOS DA MEDULA ESPINHAL, ESPASTICIDADE MUSCULAR, TECNOLOGIAS DA SAÚDE

    Versão PublicadaAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MARIA, Renata Manzano et al. Custom built device for spasticity evaluation associated to spinal cord injury: a redundant signal to electrogoniometer in pendulum test. Proceedings. Setúbal: Escola de Engenharia de São Carlos, Universidade de São Paulo. Disponível em: http://dx.doi.org/10.5220/0004234001200126. Acesso em: 16 set. 2024. , 2013
    • APA

      Maria, R. M., Alonso, K. C., Azevedo, E. R. F. B. M. de, Varoto, R., & Cliquet Junior, A. (2013). Custom built device for spasticity evaluation associated to spinal cord injury: a redundant signal to electrogoniometer in pendulum test. Proceedings. Setúbal: Escola de Engenharia de São Carlos, Universidade de São Paulo. doi:10.5220/0004234001200126
    • NLM

      Maria RM, Alonso KC, Azevedo ERFBM de, Varoto R, Cliquet Junior A. Custom built device for spasticity evaluation associated to spinal cord injury: a redundant signal to electrogoniometer in pendulum test [Internet]. Proceedings. 2013 ;1[citado 2024 set. 16 ] Available from: http://dx.doi.org/10.5220/0004234001200126
    • Vancouver

      Maria RM, Alonso KC, Azevedo ERFBM de, Varoto R, Cliquet Junior A. Custom built device for spasticity evaluation associated to spinal cord injury: a redundant signal to electrogoniometer in pendulum test [Internet]. Proceedings. 2013 ;1[citado 2024 set. 16 ] Available from: http://dx.doi.org/10.5220/0004234001200126
  • Source: Abstracts. Conference titles: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Unidades: FMRP, EESC

    Assunto: BIOENGENHARIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ASSAD, D. A. B. et al. Design of a removable modulate support bar for individuals with impaired locomotor function. 2012, Anais.. San Diego: Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, 2012. . Acesso em: 16 set. 2024.
    • APA

      Assad, D. A. B., Elui, V. M. C., Fortulan, C. A., & Medola, F. O. (2012). Design of a removable modulate support bar for individuals with impaired locomotor function. In Abstracts. San Diego: Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo.
    • NLM

      Assad DAB, Elui VMC, Fortulan CA, Medola FO. Design of a removable modulate support bar for individuals with impaired locomotor function. Abstracts. 2012 ;[citado 2024 set. 16 ]
    • Vancouver

      Assad DAB, Elui VMC, Fortulan CA, Medola FO. Design of a removable modulate support bar for individuals with impaired locomotor function. Abstracts. 2012 ;[citado 2024 set. 16 ]
  • Source: Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. Unidade: EESC

    Subjects: BIOENGENHARIA, BIOMATERIAIS CERÂMICOS, ENGENHARIA MECÂNICA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      NEVES, Etney e FORTULAN, Carlos Alberto e PURQUERIO, Benedito de Moraes. Caracterização mecânica do vitrocerâmico inteligente de anortita com abordagem dos resultados para aplicação em bioengenharia. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, v. 2, n. 4, p. 17-22, 2012Tradução . . Acesso em: 16 set. 2024.
    • APA

      Neves, E., Fortulan, C. A., & Purquerio, B. de M. (2012). Caracterização mecânica do vitrocerâmico inteligente de anortita com abordagem dos resultados para aplicação em bioengenharia. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, 2( 4), 17-22.
    • NLM

      Neves E, Fortulan CA, Purquerio B de M. Caracterização mecânica do vitrocerâmico inteligente de anortita com abordagem dos resultados para aplicação em bioengenharia. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2012 ; 2( 4): 17-22.[citado 2024 set. 16 ]
    • Vancouver

      Neves E, Fortulan CA, Purquerio B de M. Caracterização mecânica do vitrocerâmico inteligente de anortita com abordagem dos resultados para aplicação em bioengenharia. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2012 ; 2( 4): 17-22.[citado 2024 set. 16 ]
  • Source: Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. Unidade: EESC

    Subjects: BIOENGENHARIA, LASER NÃO CIRÚRGICO, REPARO ÓSSEO, RATOS

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ARRUDA, Emiliano Rodrigo de Barros et al. Efeitos causados por laserterapia de baixa intensidade sobre o comportamento osteocondutor do vitrocerâmico elaborado a partir do biovidro genérico 45S5. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, v. 2, n. abr./ju 2012, p. 9-15, 2012Tradução . . Disponível em: http://www.hestia.org.br/wp-content/uploads/2013/12/01Port.pdf. Acesso em: 16 set. 2024.
    • APA

      Arruda, E. R. de B., Rollo, J. M. D. de A., Pizani, P. S., & Neves, E. (2012). Efeitos causados por laserterapia de baixa intensidade sobre o comportamento osteocondutor do vitrocerâmico elaborado a partir do biovidro genérico 45S5. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, 2( abr./ju 2012), 9-15. Recuperado de http://www.hestia.org.br/wp-content/uploads/2013/12/01Port.pdf
    • NLM

      Arruda ER de B, Rollo JMD de A, Pizani PS, Neves E. Efeitos causados por laserterapia de baixa intensidade sobre o comportamento osteocondutor do vitrocerâmico elaborado a partir do biovidro genérico 45S5 [Internet]. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2012 ; 2( abr./ju 2012): 9-15.[citado 2024 set. 16 ] Available from: http://www.hestia.org.br/wp-content/uploads/2013/12/01Port.pdf
    • Vancouver

      Arruda ER de B, Rollo JMD de A, Pizani PS, Neves E. Efeitos causados por laserterapia de baixa intensidade sobre o comportamento osteocondutor do vitrocerâmico elaborado a partir do biovidro genérico 45S5 [Internet]. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2012 ; 2( abr./ju 2012): 9-15.[citado 2024 set. 16 ] Available from: http://www.hestia.org.br/wp-content/uploads/2013/12/01Port.pdf
  • Source: Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. Unidade: EESC

    Subjects: BIOENGENHARIA, LASER NÃO CIRÚRGICO, REPARO ÓSSEO, RATOS

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ARRUDA, Emiliano Rodrigo de Barros et al. Biocompatibilidade e bioatividade do biovidro genérico 45S5 cristalizado sob condições controladas. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, v. 1, n. 1, p. 19-25, 2011Tradução . . Disponível em: http://www.hestia.org.br/wp-content/uploads/2012/07/CITINOAno1V01N1Port02.pdf. Acesso em: 16 set. 2024.
    • APA

      Arruda, E. R. de B., Rollo, J. M. D. de A., Pizani, P. S., & Neves, E. (2011). Biocompatibilidade e bioatividade do biovidro genérico 45S5 cristalizado sob condições controladas. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade, 1( 1), 19-25. Recuperado de http://www.hestia.org.br/wp-content/uploads/2012/07/CITINOAno1V01N1Port02.pdf
    • NLM

      Arruda ER de B, Rollo JMD de A, Pizani PS, Neves E. Biocompatibilidade e bioatividade do biovidro genérico 45S5 cristalizado sob condições controladas [Internet]. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2011 ; 1( 1): 19-25.[citado 2024 set. 16 ] Available from: http://www.hestia.org.br/wp-content/uploads/2012/07/CITINOAno1V01N1Port02.pdf
    • Vancouver

      Arruda ER de B, Rollo JMD de A, Pizani PS, Neves E. Biocompatibilidade e bioatividade do biovidro genérico 45S5 cristalizado sob condições controladas [Internet]. Revista CITINO : Ciência, Tecnologia, Inovação e Oportunidade. 2011 ; 1( 1): 19-25.[citado 2024 set. 16 ] Available from: http://www.hestia.org.br/wp-content/uploads/2012/07/CITINOAno1V01N1Port02.pdf
  • Unidade: EESC

    Subjects: MÁQUINAS ELÉTRICAS, MÉTODO DOS ELEMENTOS FINITOS, PRÓTESE, MEMBROS SUPERIORES, BIOENGENHARIA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      JULIANI, Aline Durrer Patelli. Projeto e construção de um motor elétrico linear aplicado à bioengenharia. 2011. Tese (Doutorado) – Universidade de São Paulo, São Carlos, 2011. Disponível em: http://www.teses.usp.br/teses/disponiveis/18/18153/tde-04032011-150222/. Acesso em: 16 set. 2024.
    • APA

      Juliani, A. D. P. (2011). Projeto e construção de um motor elétrico linear aplicado à bioengenharia (Tese (Doutorado). Universidade de São Paulo, São Carlos. Recuperado de http://www.teses.usp.br/teses/disponiveis/18/18153/tde-04032011-150222/
    • NLM

      Juliani ADP. Projeto e construção de um motor elétrico linear aplicado à bioengenharia [Internet]. 2011 ;[citado 2024 set. 16 ] Available from: http://www.teses.usp.br/teses/disponiveis/18/18153/tde-04032011-150222/
    • Vancouver

      Juliani ADP. Projeto e construção de um motor elétrico linear aplicado à bioengenharia [Internet]. 2011 ;[citado 2024 set. 16 ] Available from: http://www.teses.usp.br/teses/disponiveis/18/18153/tde-04032011-150222/
  • Source: Anais. Conference titles: Congreso Argentino de Bioingeniería. Unidades: EESC, FMRP

    Subjects: TECNOLOGIAS DA SAÚDE, ERGOMETRIA, BIOENGENHARIA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MEDOLA, Fausto Orsi et al. Ergonomia no design e avaliação dos sispositivos de tecnologia assistiva: uma revisão narrativa. 2011, Anais.. Mar del Plata, Argentina: Sociedad Argentina de Bioingenieria, 2011. Disponível em: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_41.pdf. Acesso em: 16 set. 2024.
    • APA

      Medola, F. O., Fortulan, C. A., Santana, C. da S., & Elui, V. M. C. (2011). Ergonomia no design e avaliação dos sispositivos de tecnologia assistiva: uma revisão narrativa. In Anais. Mar del Plata, Argentina: Sociedad Argentina de Bioingenieria. Recuperado de http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_41.pdf
    • NLM

      Medola FO, Fortulan CA, Santana C da S, Elui VMC. Ergonomia no design e avaliação dos sispositivos de tecnologia assistiva: uma revisão narrativa [Internet]. Anais. 2011 ;[citado 2024 set. 16 ] Available from: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_41.pdf
    • Vancouver

      Medola FO, Fortulan CA, Santana C da S, Elui VMC. Ergonomia no design e avaliação dos sispositivos de tecnologia assistiva: uma revisão narrativa [Internet]. Anais. 2011 ;[citado 2024 set. 16 ] Available from: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_41.pdf
  • Source: Livro de resumo. Conference titles: Workshop Bone as Engineering Material. Unidades: EESC, IQSC

    Assunto: BIOENGENHARIA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      AMARAL, Mauricio Bordini do et al. Bone regeneration in calvaria critical-size defects: computerized microtomography evaluation. 2011, Anais.. São Carlos: USP, Bioengenharia (EESC/FMRP/IQSC), 2011. Disponível em: http://www.eesc.usp.br/bioeng/workshopbem/Proceedings/Proceedinngs%20BEM.pdf. Acesso em: 16 set. 2024.
    • APA

      Amaral, M. B. do, Silva Júnior, N. F. da, Martins, V. da C. A., & Plepis, A. M. de G. (2011). Bone regeneration in calvaria critical-size defects: computerized microtomography evaluation. In Livro de resumo. São Carlos: USP, Bioengenharia (EESC/FMRP/IQSC). Recuperado de http://www.eesc.usp.br/bioeng/workshopbem/Proceedings/Proceedinngs%20BEM.pdf
    • NLM

      Amaral MB do, Silva Júnior NF da, Martins V da CA, Plepis AM de G. Bone regeneration in calvaria critical-size defects: computerized microtomography evaluation [Internet]. Livro de resumo. 2011 ;[citado 2024 set. 16 ] Available from: http://www.eesc.usp.br/bioeng/workshopbem/Proceedings/Proceedinngs%20BEM.pdf
    • Vancouver

      Amaral MB do, Silva Júnior NF da, Martins V da CA, Plepis AM de G. Bone regeneration in calvaria critical-size defects: computerized microtomography evaluation [Internet]. Livro de resumo. 2011 ;[citado 2024 set. 16 ] Available from: http://www.eesc.usp.br/bioeng/workshopbem/Proceedings/Proceedinngs%20BEM.pdf
  • Source: Anais. Conference titles: Congreso Argentino de Bioingeniería. Unidades: EESC, FMRP

    Subjects: CADEIRA DE RODAS, TECNOLOGIAS DA SAÚDE, EVOLUÇÃO TECNOLÓGICA, BIOENGENHARIA

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MEDOLA, Fausto Orsi et al. Análise da evolução tecnológica da cadeira de rodas: desafios e limitações. 2011, Anais.. Mar del Plata, Argentina: Sociedad Argentina de Bioingenieria, 2011. Disponível em: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_40.pdf. Acesso em: 16 set. 2024.
    • APA

      Medola, F. O., Fortulan, C. A., Santana, C. da S., & Elui, V. M. C. (2011). Análise da evolução tecnológica da cadeira de rodas: desafios e limitações. In Anais. Mar del Plata, Argentina: Sociedad Argentina de Bioingenieria. Recuperado de http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_40.pdf
    • NLM

      Medola FO, Fortulan CA, Santana C da S, Elui VMC. Análise da evolução tecnológica da cadeira de rodas: desafios e limitações [Internet]. Anais. 2011 ;[citado 2024 set. 16 ] Available from: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_40.pdf
    • Vancouver

      Medola FO, Fortulan CA, Santana C da S, Elui VMC. Análise da evolução tecnológica da cadeira de rodas: desafios e limitações [Internet]. Anais. 2011 ;[citado 2024 set. 16 ] Available from: http://www.sabi2011.fi.mdp.edu.ar/proceedings/SABI/Pdf/SABI2011_40.pdf
  • Source: Clinical Orthopaedics and Related Research. Unidade: EESC

    Subjects: BIOENGENHARIA, OSSO E OSSOS, OSTEOPOROSE, RATOS

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      GUSMÃO, Carlos Vinícius Buarque de et al. Low-intensity ultrasound increases FAK, ERK-1/2, and IRS-1 expression of intact rat bones in a noncumulative manner. Clinical Orthopaedics and Related Research, v. 468, n. 4, p. 1149-1156, 2010Tradução . . Disponível em: https://doi.org/10.1007/s11999-009-1146-6. Acesso em: 16 set. 2024.
    • APA

      Gusmão, C. V. B. de, Pauli, J. R., Saad, M. J. A., Alves, J. M., & Belangero, W. D. (2010). Low-intensity ultrasound increases FAK, ERK-1/2, and IRS-1 expression of intact rat bones in a noncumulative manner. Clinical Orthopaedics and Related Research, 468( 4), 1149-1156. doi:10.1007/s11999-009-1146-6
    • NLM

      Gusmão CVB de, Pauli JR, Saad MJA, Alves JM, Belangero WD. Low-intensity ultrasound increases FAK, ERK-1/2, and IRS-1 expression of intact rat bones in a noncumulative manner [Internet]. Clinical Orthopaedics and Related Research. 2010 ; 468( 4): 1149-1156.[citado 2024 set. 16 ] Available from: https://doi.org/10.1007/s11999-009-1146-6
    • Vancouver

      Gusmão CVB de, Pauli JR, Saad MJA, Alves JM, Belangero WD. Low-intensity ultrasound increases FAK, ERK-1/2, and IRS-1 expression of intact rat bones in a noncumulative manner [Internet]. Clinical Orthopaedics and Related Research. 2010 ; 468( 4): 1149-1156.[citado 2024 set. 16 ] Available from: https://doi.org/10.1007/s11999-009-1146-6
  • Source: REM : Revista da Escola de Minas. Unidade: EESC

    Subjects: BIOENGENHARIA, AÇO INOXIDÁVEL MARTENSÍTICO, CORROSÃO

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      RODRIGUES, César Augusto Duarte et al. Qualidade do aço inoxidável martensítico do tipo AISI-420 utilizado na confecção de ferramentas cirúrgicas. REM : Revista da Escola de Minas, v. 62, n. 4, p. 475-480, 2009Tradução . . Disponível em: https://doi.org/10.1590/S0370-44672009000400010. Acesso em: 16 set. 2024.
    • APA

      Rodrigues, C. A. D., Enokibara, F., Leiva, T. P., Nunes, I. A., & Rollo, J. M. D. de A. (2009). Qualidade do aço inoxidável martensítico do tipo AISI-420 utilizado na confecção de ferramentas cirúrgicas. REM : Revista da Escola de Minas, 62( 4), 475-480. doi:10.1590/S0370-44672009000400010
    • NLM

      Rodrigues CAD, Enokibara F, Leiva TP, Nunes IA, Rollo JMD de A. Qualidade do aço inoxidável martensítico do tipo AISI-420 utilizado na confecção de ferramentas cirúrgicas [Internet]. REM : Revista da Escola de Minas. 2009 ; 62( 4): 475-480.[citado 2024 set. 16 ] Available from: https://doi.org/10.1590/S0370-44672009000400010
    • Vancouver

      Rodrigues CAD, Enokibara F, Leiva TP, Nunes IA, Rollo JMD de A. Qualidade do aço inoxidável martensítico do tipo AISI-420 utilizado na confecção de ferramentas cirúrgicas [Internet]. REM : Revista da Escola de Minas. 2009 ; 62( 4): 475-480.[citado 2024 set. 16 ] Available from: https://doi.org/10.1590/S0370-44672009000400010

Digital Library of Intellectual Production of Universidade de São Paulo     2012 - 2024