Filtros : "Abutments" Limpar

Filtros



Refine with date range


  • Source: Brazilian Dental Journal. Unidade: FORP

    Subjects: IMPLANTES DENTÁRIOS, MATERIAIS DENTÁRIOS, TITÂNIO, ZIRCÔNIO

    Versão PublicadaAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      RUSCHEL, George Hebert et al. Internal and marginal fit and fracture strength of narrow diameter dental implant-abutment assembly. Brazilian Dental Journal, v. 31, n. 2, p. 127-134, 2020Tradução . . Disponível em: https://doi.org/10.1590/0103-6440202002937. Acesso em: 24 fev. 2026.
    • APA

      Ruschel, G. H., Bacchi, A., Moris, I. C. M., Poole, S. F., Ribeiro, R. F., & Gomes, É. A. (2020). Internal and marginal fit and fracture strength of narrow diameter dental implant-abutment assembly. Brazilian Dental Journal, 31( 2), 127-134. doi:10.1590/0103-6440202002937
    • NLM

      Ruschel GH, Bacchi A, Moris ICM, Poole SF, Ribeiro RF, Gomes ÉA. Internal and marginal fit and fracture strength of narrow diameter dental implant-abutment assembly [Internet]. Brazilian Dental Journal. 2020 ; 31( 2): 127-134.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1590/0103-6440202002937
    • Vancouver

      Ruschel GH, Bacchi A, Moris ICM, Poole SF, Ribeiro RF, Gomes ÉA. Internal and marginal fit and fracture strength of narrow diameter dental implant-abutment assembly [Internet]. Brazilian Dental Journal. 2020 ; 31( 2): 127-134.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1590/0103-6440202002937
  • Unidade: FORP

    Subjects: MÉTODO DOS ELEMENTOS FINITOS, IMPLANTES DENTÁRIOS, FORÇA DE MORDIDA

    Acesso à fonteAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SOUZA, Gabriela Ayres de. Influência de pilares protéticos sólidos para implantes Cone Morse instalados em diferentes profundidades ósseas na distribuição de tensões: análise por elementos finitos. 2019. Dissertação (Mestrado) – Universidade de São Paulo, Ribeirão Preto, 2019. Disponível em: https://www.teses.usp.br/teses/disponiveis/58/58131/tde-04102022-174756/. Acesso em: 24 fev. 2026.
    • APA

      Souza, G. A. de. (2019). Influência de pilares protéticos sólidos para implantes Cone Morse instalados em diferentes profundidades ósseas na distribuição de tensões: análise por elementos finitos (Dissertação (Mestrado). Universidade de São Paulo, Ribeirão Preto. Recuperado de https://www.teses.usp.br/teses/disponiveis/58/58131/tde-04102022-174756/
    • NLM

      Souza GA de. Influência de pilares protéticos sólidos para implantes Cone Morse instalados em diferentes profundidades ósseas na distribuição de tensões: análise por elementos finitos [Internet]. 2019 ;[citado 2026 fev. 24 ] Available from: https://www.teses.usp.br/teses/disponiveis/58/58131/tde-04102022-174756/
    • Vancouver

      Souza GA de. Influência de pilares protéticos sólidos para implantes Cone Morse instalados em diferentes profundidades ósseas na distribuição de tensões: análise por elementos finitos [Internet]. 2019 ;[citado 2026 fev. 24 ] Available from: https://www.teses.usp.br/teses/disponiveis/58/58131/tde-04102022-174756/
  • Source: Journal of the Mechanical Behavior of Biomedical Materials. Unidade: FORP

    Assunto: IMPLANTE DENTÁRIO ENDOÓSSEO

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORIS, Izabela Cristina Maurício et al. Custom Morse taper zirconia abutments: influence on marginal fit and torque loss before and after thermomechanical cycling. Journal of the Mechanical Behavior of Biomedical Materials, v. 78, p. 241-245, 2018Tradução . . Disponível em: https://doi.org/10.1016/j.jmbbm.2017.11.027. Acesso em: 24 fev. 2026.
    • APA

      Moris, I. C. M., Faria, A. C. L., Ribeiro, R. F., Fok, A. S. -L., & Rodrigues, R. C. S. (2018). Custom Morse taper zirconia abutments: influence on marginal fit and torque loss before and after thermomechanical cycling. Journal of the Mechanical Behavior of Biomedical Materials, 78, 241-245. doi:10.1016/j.jmbbm.2017.11.027
    • NLM

      Moris ICM, Faria ACL, Ribeiro RF, Fok AS-L, Rodrigues RCS. Custom Morse taper zirconia abutments: influence on marginal fit and torque loss before and after thermomechanical cycling [Internet]. Journal of the Mechanical Behavior of Biomedical Materials. 2018 ; 78 241-245.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1016/j.jmbbm.2017.11.027
    • Vancouver

      Moris ICM, Faria ACL, Ribeiro RF, Fok AS-L, Rodrigues RCS. Custom Morse taper zirconia abutments: influence on marginal fit and torque loss before and after thermomechanical cycling [Internet]. Journal of the Mechanical Behavior of Biomedical Materials. 2018 ; 78 241-245.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1016/j.jmbbm.2017.11.027
  • Source: Clinical Oral Implants Research. Unidade: FORP

    Subjects: IMPLANTES DENTÁRIOS, RETENÇÃO, COROAS DENTÁRIAS, CIMENTAÇÃO DE COROAS, PARAFUSOS ORTODÔNTICOS, FATORES BIOLÓGICOS

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORIS, Izabela Cristina Maurício et al. Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment-crown-connections after cyclic loading. Clinical Oral Implants Research, v. 28, n. 4, p. 432-436, 2017Tradução . . Disponível em: https://doi.org/10.1111/clr.12816. Acesso em: 24 fev. 2026.
    • APA

      Moris, I. C. M., Faria, A. C. L., Ribeiro, R. F., & Rodrigues, R. C. S. (2017). Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment-crown-connections after cyclic loading. Clinical Oral Implants Research, 28( 4), 432-436. doi:10.1111/clr.12816
    • NLM

      Moris ICM, Faria ACL, Ribeiro RF, Rodrigues RCS. Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment-crown-connections after cyclic loading [Internet]. Clinical Oral Implants Research. 2017 ; 28( 4): 432-436.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1111/clr.12816
    • Vancouver

      Moris ICM, Faria ACL, Ribeiro RF, Rodrigues RCS. Abutments with reduced diameter for both cement and screw retentions: analysis of failure modes and misfit of abutment-crown-connections after cyclic loading [Internet]. Clinical Oral Implants Research. 2017 ; 28( 4): 432-436.[citado 2026 fev. 24 ] Available from: https://doi.org/10.1111/clr.12816
  • Unidade: FORP

    Subjects: ODONTOLOGIA, IMPLANTES DENTÁRIOS, PRÓTESES E IMPLANTES

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      PROVINCIATTI, Mauricio Martins. Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas. 2016. Dissertação (Mestrado) – Universidade de São Paulo, Ribeirão Preto, 2016. Disponível em: http://www.teses.usp.br/teses/disponiveis/58/58131/tde-22022016-155915/. Acesso em: 24 fev. 2026.
    • APA

      Provinciatti, M. M. (2016). Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas (Dissertação (Mestrado). Universidade de São Paulo, Ribeirão Preto. Recuperado de http://www.teses.usp.br/teses/disponiveis/58/58131/tde-22022016-155915/
    • NLM

      Provinciatti MM. Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas [Internet]. 2016 ;[citado 2026 fev. 24 ] Available from: http://www.teses.usp.br/teses/disponiveis/58/58131/tde-22022016-155915/
    • Vancouver

      Provinciatti MM. Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas [Internet]. 2016 ;[citado 2026 fev. 24 ] Available from: http://www.teses.usp.br/teses/disponiveis/58/58131/tde-22022016-155915/

Digital Library of Intellectual Production of Universidade de São Paulo     2012 - 2026