Filtros : "BAFFA FILHO, OSWALDO" "Physiological Measurement" Removidos: "IFSC888" "mf" Limpar

Filtros



Limitar por data


  • Fonte: Physiological Measurement. Unidade: FFCLRP

    Assuntos: FETO, CORAÇÃO, SISTEMA NERVOSO AUTÔNOMO, MAGNETISMO

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORAES, Eder Rezende e MURTA JUNIOR, Luiz Otavio e BAFFA, Oswaldo. Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms. Physiological Measurement, v. 33, n. 10, p. 1563-1583, 2012Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/33/10/1563. Acesso em: 06 ago. 2024.
    • APA

      Moraes, E. R., Murta Junior, L. O., & Baffa, O. (2012). Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms. Physiological Measurement, 33( 10), 1563-1583. doi:10.1088/0967-3334/33/10/1563
    • NLM

      Moraes ER, Murta Junior LO, Baffa O. Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms [Internet]. Physiological Measurement. 2012 ; 33( 10): 1563-1583.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/33/10/1563
    • Vancouver

      Moraes ER, Murta Junior LO, Baffa O. Linear and nonlinear measures of fetal heart rate patterns evaluated on very short fetal magnetocardiograms [Internet]. Physiological Measurement. 2012 ; 33( 10): 1563-1583.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/33/10/1563
  • Fonte: Physiological Measurement. Unidades: FMRP, FFCLRP

    Assuntos: ESVAZIAMENTO GÁSTRICO, FARMACOLOGIA

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ANDREIS, Uilian et al. Gastric motility evaluated by electrogastrography and alternating current biosusceptometry in dogs. Physiological Measurement, v. 29, n. 9, p. 1023-1031, 2008Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/29/9/002. Acesso em: 06 ago. 2024.
    • APA

      Andreis, U., Américo, M. F., Corá, L. A., Oliveira, R. B. de, Baffa, O., & Miranda, J. R. A. (2008). Gastric motility evaluated by electrogastrography and alternating current biosusceptometry in dogs. Physiological Measurement, 29( 9), 1023-1031. doi:10.1088/0967-3334/29/9/002
    • NLM

      Andreis U, Américo MF, Corá LA, Oliveira RB de, Baffa O, Miranda JRA. Gastric motility evaluated by electrogastrography and alternating current biosusceptometry in dogs [Internet]. Physiological Measurement. 2008 ; 29( 9): 1023-1031.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/29/9/002
    • Vancouver

      Andreis U, Américo MF, Corá LA, Oliveira RB de, Baffa O, Miranda JRA. Gastric motility evaluated by electrogastrography and alternating current biosusceptometry in dogs [Internet]. Physiological Measurement. 2008 ; 29( 9): 1023-1031.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/29/9/002
  • Fonte: Physiological Measurement. Unidade: FFCLRP

    Assuntos: FISIOLOGIA, BIOFÍSICA

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ESTOMBELO-MONTESCO, C. A et al. Dependent component analysis for the magnetogastrographic detection of human electrical response activity. Physiological Measurement, v. 28, p. 1029-1044, 2007Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/28/9/005. Acesso em: 06 ago. 2024.
    • APA

      Estombelo-Montesco, C. A., Araújo, D. B. de, Roque, A. C., Moraes, E. R., Barros, A. K., Wakai, R. T., & Baffa, O. (2007). Dependent component analysis for the magnetogastrographic detection of human electrical response activity. Physiological Measurement, 28, 1029-1044. doi:10.1088/0967-3334/28/9/005
    • NLM

      Estombelo-Montesco CA, Araújo DB de, Roque AC, Moraes ER, Barros AK, Wakai RT, Baffa O. Dependent component analysis for the magnetogastrographic detection of human electrical response activity [Internet]. Physiological Measurement. 2007 ; 28 1029-1044.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/28/9/005
    • Vancouver

      Estombelo-Montesco CA, Araújo DB de, Roque AC, Moraes ER, Barros AK, Wakai RT, Baffa O. Dependent component analysis for the magnetogastrographic detection of human electrical response activity [Internet]. Physiological Measurement. 2007 ; 28 1029-1044.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/28/9/005
  • Fonte: Physiological Measurement. Unidades: FFCLRP, FMRP

    Assuntos: DIAGNÓSTICO POR IMAGEM, SISTEMA GASTROINTESTINAL

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORAES, Eder Rezende et al. Assessment of the post-prandial distribution of intragastric contents using an automated technique. Physiological Measurement, v. 27, p. 769-776, 2006Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/27/9/001. Acesso em: 06 ago. 2024.
    • APA

      Moraes, E. R., Troncon, L. E. de A., Herculano Júnior, J. R. L., Secaf, M., Oliveira, R. B. de, & Baffa, O. (2006). Assessment of the post-prandial distribution of intragastric contents using an automated technique. Physiological Measurement, 27, 769-776. doi:10.1088/0967-3334/27/9/001
    • NLM

      Moraes ER, Troncon LE de A, Herculano Júnior JRL, Secaf M, Oliveira RB de, Baffa O. Assessment of the post-prandial distribution of intragastric contents using an automated technique [Internet]. Physiological Measurement. 2006 ; 27 769-776.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/27/9/001
    • Vancouver

      Moraes ER, Troncon LE de A, Herculano Júnior JRL, Secaf M, Oliveira RB de, Baffa O. Assessment of the post-prandial distribution of intragastric contents using an automated technique [Internet]. Physiological Measurement. 2006 ; 27 769-776.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/27/9/001
  • Fonte: Physiological Measurement. Unidades: FMRP, FFCLRP

    Assuntos: BIOFÍSICA, GASTROENTEROLOGIA (FISIOLOGIA)

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORAES, Eder R. et al. Adaptative, autiregressive spectral estimulation for analysis of eletrical signals of gastric origin. Physiological Measurement, v. 24, p. 91-106, 2003Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/24/1/307. Acesso em: 06 ago. 2024.
    • APA

      Moraes, E. R., Troncon, L. E. de A., Baffa, O., Oba-kunyioshi, A. S., Wakai, R., & Leuthold, A. (2003). Adaptative, autiregressive spectral estimulation for analysis of eletrical signals of gastric origin. Physiological Measurement, 24, 91-106. doi:10.1088/0967-3334/24/1/307
    • NLM

      Moraes ER, Troncon LE de A, Baffa O, Oba-kunyioshi AS, Wakai R, Leuthold A. Adaptative, autiregressive spectral estimulation for analysis of eletrical signals of gastric origin [Internet]. Physiological Measurement. 2003 ; 24 91-106.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/24/1/307
    • Vancouver

      Moraes ER, Troncon LE de A, Baffa O, Oba-kunyioshi AS, Wakai R, Leuthold A. Adaptative, autiregressive spectral estimulation for analysis of eletrical signals of gastric origin [Internet]. Physiological Measurement. 2003 ; 24 91-106.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/24/1/307
  • Fonte: Physiological Measurement. Unidades: FFCLRP, FMRP

    Assuntos: FERRO, DOSIMETRIA, FÍGADO, ANEMIA, HEMOCROMATOSE

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      CARNEIRO, A. A. O. et al. Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers. Physiological Measurement, v. 23, p. 683-694, 2002Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/23/4/308. Acesso em: 06 ago. 2024.
    • APA

      Carneiro, A. A. O., Baffa, O., Fernandes, J. P., & Zago, M. A. (2002). Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers. Physiological Measurement, 23, 683-694. doi:10.1088/0967-3334/23/4/308
    • NLM

      Carneiro AAO, Baffa O, Fernandes JP, Zago MA. Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers [Internet]. Physiological Measurement. 2002 ; 23 683-694.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/23/4/308
    • Vancouver

      Carneiro AAO, Baffa O, Fernandes JP, Zago MA. Theoretical evaluation of the susceptometric measurement of iron in human liver by four different susceptometers [Internet]. Physiological Measurement. 2002 ; 23 683-694.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/23/4/308
  • Fonte: Physiological Measurement. Unidades: FORP, ESALQ, FFCLRP

    Assuntos: GASTROENTEROLOGIA, BACTERIOLOGIA

    Acesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      DAGHASTANLI, Nasser Ali et al. Oesophageal transit time evaluated by a biomagnetic method. Physiological Measurement, v. 19, p. 413-420, 1998Tradução . . Disponível em: https://doi.org/10.1088/0967-3334/19/3/010. Acesso em: 06 ago. 2024.
    • APA

      Daghastanli, N. A., Braga, F. J. H. N., Oliveira, R. B. de, & Baffa, O. (1998). Oesophageal transit time evaluated by a biomagnetic method. Physiological Measurement, 19, 413-420. doi:10.1088/0967-3334/19/3/010
    • NLM

      Daghastanli NA, Braga FJHN, Oliveira RB de, Baffa O. Oesophageal transit time evaluated by a biomagnetic method [Internet]. Physiological Measurement. 1998 ; 19 413-420.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/19/3/010
    • Vancouver

      Daghastanli NA, Braga FJHN, Oliveira RB de, Baffa O. Oesophageal transit time evaluated by a biomagnetic method [Internet]. Physiological Measurement. 1998 ; 19 413-420.[citado 2024 ago. 06 ] Available from: https://doi.org/10.1088/0967-3334/19/3/010

Biblioteca Digital de Produção Intelectual da Universidade de São Paulo     2012 - 2024