Filtros : "IF-FNC" "MARIANO, LEANDRO" Limpar

Filtros



Refine with date range


  • Source: Biomedical Physics and Engineering Express. Unidade: IF

    Subjects: FÍSICA MÉDICA, FÍSICA NUCLEAR, BIOFÍSICA, MAMOGRAFIA, ESPECTROMETRIA, RADIOLOGIA, ESPECTROSCOPIA ATÔMICA, RADIOGRAFIA, MAMA, ESTATÍSTICAS DE SAÚDE, HIPÓTESE, DOSIMETRIA

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTORO-FERNANDES, Victor et al. Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra. Biomedical Physics and Engineering Express, v. 6, n. 3, 2020Tradução . . Disponível em: https://doi.org/10.1088/2057-1976/ab817d. Acesso em: 10 jun. 2024.
    • APA

      Santoro-Fernandes, V., Santos, J. C., Mariano, L., Vanin, V., & Costa, P. R. (2020). Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra. Biomedical Physics and Engineering Express, 6( 3). doi:10.1088/2057-1976/ab817d
    • NLM

      Santoro-Fernandes V, Santos JC, Mariano L, Vanin V, Costa PR. Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra [Internet]. Biomedical Physics and Engineering Express. 2020 ; 6( 3):[citado 2024 jun. 10 ] Available from: https://doi.org/10.1088/2057-1976/ab817d
    • Vancouver

      Santoro-Fernandes V, Santos JC, Mariano L, Vanin V, Costa PR. Uncertainty estimation and statistical comparative methodology for mammography x-ray energy spectra [Internet]. Biomedical Physics and Engineering Express. 2020 ; 6( 3):[citado 2024 jun. 10 ] Available from: https://doi.org/10.1088/2057-1976/ab817d
  • Source: Physica Medica. Unidade: IF

    Subjects: FÍSICA NUCLEAR, FÍSICA MÉDICA, TECIDOS (ANATOMIA), RAIOS X, RADIOLOGIA

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MARIANO, Leandro e COSTA, P. R. Abstract ID: 94 Development of a methodology for formulating radiologically equivalent materials to human tissues. Physica Medica, v. 42, p. 20-21, 2017Tradução . . Disponível em: https://doi.org/10.1016/j.ejmp.2017.09.051. Acesso em: 10 jun. 2024.
    • APA

      Mariano, L., & Costa, P. R. (2017). Abstract ID: 94 Development of a methodology for formulating radiologically equivalent materials to human tissues. Physica Medica, 42, 20-21. doi:10.1016/j.ejmp.2017.09.051
    • NLM

      Mariano L, Costa PR. Abstract ID: 94 Development of a methodology for formulating radiologically equivalent materials to human tissues [Internet]. Physica Medica. 2017 ; 42 20-21.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1016/j.ejmp.2017.09.051
    • Vancouver

      Mariano L, Costa PR. Abstract ID: 94 Development of a methodology for formulating radiologically equivalent materials to human tissues [Internet]. Physica Medica. 2017 ; 42 20-21.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1016/j.ejmp.2017.09.051
  • Source: Physica Medica. Unidade: IF

    Subjects: FÍSICA NUCLEAR, FÍSICA MÉDICA, DOSIMETRIA, MAMOGRAFIA, ESPECTROMETRIA, RAIOS X

    PrivadoAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      FERNANDES, Victor et al. Abstract ID: 189 Uncertainty estimation of MC simulated mammography spectra. Physica Medica, v. 42, p. 41-42, 2017Tradução . . Disponível em: https://doi.org/10.1016/j.ejmp.2017.09.101. Acesso em: 10 jun. 2024.
    • APA

      Fernandes, V., Mariano, L., Costa, P. R., & Vanin, V. (2017). Abstract ID: 189 Uncertainty estimation of MC simulated mammography spectra. Physica Medica, 42, 41-42. doi:10.1016/j.ejmp.2017.09.101
    • NLM

      Fernandes V, Mariano L, Costa PR, Vanin V. Abstract ID: 189 Uncertainty estimation of MC simulated mammography spectra [Internet]. Physica Medica. 2017 ; 42 41-42.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1016/j.ejmp.2017.09.101
    • Vancouver

      Fernandes V, Mariano L, Costa PR, Vanin V. Abstract ID: 189 Uncertainty estimation of MC simulated mammography spectra [Internet]. Physica Medica. 2017 ; 42 41-42.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1016/j.ejmp.2017.09.101
  • Source: Journal of Radiological Protection. Unidade: IF

    Subjects: FÍSICA NUCLEAR, FÍSICA MÉDICA, ESPECTROS, RAIOS X

    Versão PublicadaAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      GONZALES, A H Lopez et al. Evaluation of mean conversion coefficients from air-kerma to H *(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range. Journal of Radiological Protection, v. 36, n. 4, p. 842-857, 2016Tradução . . Disponível em: https://doi.org/10.1088/0952-4746/36/4/842. Acesso em: 10 jun. 2024.
    • APA

      Gonzales, A. H. L., Santos, J. C., Mariano, L., Tomal, A., & Costa, P. R. (2016). Evaluation of mean conversion coefficients from air-kerma to H *(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range. Journal of Radiological Protection, 36( 4), 842-857. doi:10.1088/0952-4746/36/4/842
    • NLM

      Gonzales AHL, Santos JC, Mariano L, Tomal A, Costa PR. Evaluation of mean conversion coefficients from air-kerma to H *(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range [Internet]. Journal of Radiological Protection. 2016 ; 36( 4): 842-857.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1088/0952-4746/36/4/842
    • Vancouver

      Gonzales AHL, Santos JC, Mariano L, Tomal A, Costa PR. Evaluation of mean conversion coefficients from air-kerma to H *(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range [Internet]. Journal of Radiological Protection. 2016 ; 36( 4): 842-857.[citado 2024 jun. 10 ] Available from: https://doi.org/10.1088/0952-4746/36/4/842
  • Source: ISSSD 2014: Proceedings. Conference titles: XIV International Symposium on Solid State Dosimetry. Unidade: IF

    Subjects: MEDICINA NUCLEAR, FÍSICA MÉDICA, ESPECTROSCOPIA DE RAIO X, DOSAGEM DE RADIAÇÃO

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTOS, Josilene C. et al. Transmission properties of Barite Mortar using x-ray spectra measured with CdTe detector. ISSSD 2014: Proceedings. Amsterdam: Elsevier. Disponível em: https://inis.iaea.org/collection/NCLCollectionStore/_Public/45/099/45099965.pdf. Acesso em: 10 jun. 2024. , 2014
    • APA

      Santos, J. C., Tomal, A., Mariano, L., & Costa, P. R. (2014). Transmission properties of Barite Mortar using x-ray spectra measured with CdTe detector. ISSSD 2014: Proceedings. Amsterdam: Elsevier. Recuperado de https://inis.iaea.org/collection/NCLCollectionStore/_Public/45/099/45099965.pdf
    • NLM

      Santos JC, Tomal A, Mariano L, Costa PR. Transmission properties of Barite Mortar using x-ray spectra measured with CdTe detector [Internet]. ISSSD 2014: Proceedings. 2014 ; 100 of Applied radiation and isotopes 11 .[citado 2024 jun. 10 ] Available from: https://inis.iaea.org/collection/NCLCollectionStore/_Public/45/099/45099965.pdf
    • Vancouver

      Santos JC, Tomal A, Mariano L, Costa PR. Transmission properties of Barite Mortar using x-ray spectra measured with CdTe detector [Internet]. ISSSD 2014: Proceedings. 2014 ; 100 of Applied radiation and isotopes 11 .[citado 2024 jun. 10 ] Available from: https://inis.iaea.org/collection/NCLCollectionStore/_Public/45/099/45099965.pdf
  • Source: Medical Physics International. Unidade: IF

    Subjects: MEDICINA NUCLEAR, FÍSICA MÉDICA, TOMOGRAFIA COMPUTADORIZADA POR RAIOS X, RADIOLOGIA, DOSAGEM DE RADIAÇÃO

    Acesso à fonteHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTOS, Josilene C. et al. Evaluation of x-ray spectra transmitted by shielding material used in Brazil. Medical Physics International. York: IOMP-International Organization for Medical Physics. Disponível em: http://www.mpijournal.org/pdf/2013-02/MPI-2%20with%20suppl%20IPEM2013.pdf. Acesso em: 10 jun. 2024. , 2013
    • APA

      Santos, J. C., Mariano, L., Tomal, A., & Costa, P. R. (2013). Evaluation of x-ray spectra transmitted by shielding material used in Brazil. Medical Physics International. York: IOMP-International Organization for Medical Physics. Recuperado de http://www.mpijournal.org/pdf/2013-02/MPI-2%20with%20suppl%20IPEM2013.pdf
    • NLM

      Santos JC, Mariano L, Tomal A, Costa PR. Evaluation of x-ray spectra transmitted by shielding material used in Brazil [Internet]. Medical Physics International. 2013 ; 1( 2): 616.[citado 2024 jun. 10 ] Available from: http://www.mpijournal.org/pdf/2013-02/MPI-2%20with%20suppl%20IPEM2013.pdf
    • Vancouver

      Santos JC, Mariano L, Tomal A, Costa PR. Evaluation of x-ray spectra transmitted by shielding material used in Brazil [Internet]. Medical Physics International. 2013 ; 1( 2): 616.[citado 2024 jun. 10 ] Available from: http://www.mpijournal.org/pdf/2013-02/MPI-2%20with%20suppl%20IPEM2013.pdf
  • Conference titles: International Symposium on Radiation Physics. Unidade: IF

    Subjects: MEDICINA NUCLEAR, FÍSICA MÉDICA, RADIOLOGIA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MARIANO, L. e COSTA, P. R. Study of the attenuation properties of water-equivalent materials using the Monte Carlo Method. 2012, Anais.. Rio de Janeiro: Instituto de Física, Universidade de São Paulo, 2012. . Acesso em: 10 jun. 2024.
    • APA

      Mariano, L., & Costa, P. R. (2012). Study of the attenuation properties of water-equivalent materials using the Monte Carlo Method. In . Rio de Janeiro: Instituto de Física, Universidade de São Paulo.
    • NLM

      Mariano L, Costa PR. Study of the attenuation properties of water-equivalent materials using the Monte Carlo Method. 2012 ;[citado 2024 jun. 10 ]
    • Vancouver

      Mariano L, Costa PR. Study of the attenuation properties of water-equivalent materials using the Monte Carlo Method. 2012 ;[citado 2024 jun. 10 ]

Digital Library of Intellectual Production of Universidade de São Paulo     2012 - 2024