Filtros : "Indexado no Aqualine Abstracts" "QUÍMICA ANALÍTICA" Removidos: "Ciência Animal e Pastagens" "602" "qw" Limpar

Filtros



Refine with date range


  • Source: Talanta. Unidade: IQ

    Subjects: ANÁLISE POR INJEÇÃO SEQUENCIAL, QUÍMICA ANALÍTICA, SUPERFÍCIES DE RESPOSTA

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SANTOS, Allan Cezar Vieira dos e MASINI, Jorge Cesar. Applying sequential injection analysis (SIA) and response surface methodology for optimization of Fenton-based processes. Talanta, v. 77, n. 3, p. 1081-1086, 2009Tradução . . Acesso em: 09 jul. 2024.
    • APA

      Santos, A. C. V. dos, & Masini, J. C. (2009). Applying sequential injection analysis (SIA) and response surface methodology for optimization of Fenton-based processes. Talanta, 77( 3), 1081-1086.
    • NLM

      Santos ACV dos, Masini JC. Applying sequential injection analysis (SIA) and response surface methodology for optimization of Fenton-based processes. Talanta. 2009 ; 77( 3): 1081-1086.[citado 2024 jul. 09 ]
    • Vancouver

      Santos ACV dos, Masini JC. Applying sequential injection analysis (SIA) and response surface methodology for optimization of Fenton-based processes. Talanta. 2009 ; 77( 3): 1081-1086.[citado 2024 jul. 09 ]
  • Source: Talanta. Unidade: IQ

    Subjects: ALUMÍNIO, QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      GRIGOLETTO, Tânia e OLIVEIRA, Elisabeth de e GUTZ, Ivano Gebhardt Rolf. A new electrolytic dissolution of aluminum alloys and determination of some constituents by inductively coupled plasma optical emission spectrometry. Talanta, v. 67, n. 4, p. 791-797, 2005Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2005.04.013. Acesso em: 09 jul. 2024.
    • APA

      Grigoletto, T., Oliveira, E. de, & Gutz, I. G. R. (2005). A new electrolytic dissolution of aluminum alloys and determination of some constituents by inductively coupled plasma optical emission spectrometry. Talanta, 67( 4), 791-797. doi:10.1016/j.talanta.2005.04.013
    • NLM

      Grigoletto T, Oliveira E de, Gutz IGR. A new electrolytic dissolution of aluminum alloys and determination of some constituents by inductively coupled plasma optical emission spectrometry [Internet]. Talanta. 2005 ; 67( 4): 791-797.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2005.04.013
    • Vancouver

      Grigoletto T, Oliveira E de, Gutz IGR. A new electrolytic dissolution of aluminum alloys and determination of some constituents by inductively coupled plasma optical emission spectrometry [Internet]. Talanta. 2005 ; 67( 4): 791-797.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2005.04.013
  • Source: Talanta. Unidades: IQ, CENA

    Subjects: ANÁLISE EM FLUXO CONTÍNUO, QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ROCHA, Fábio Rodrigo Piovezani et al. A portable and low cost equipment for flow injection chemiluminescence measurements. Talanta, v. 65, n. 4, p. 673-677, 2005Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2005.03.021. Acesso em: 09 jul. 2024.
    • APA

      Rocha, F. R. P., Ródenas-Torralba, E., Reis, B. F. dos, Morales-Rubio, Á., & Guardia, M. de la. (2005). A portable and low cost equipment for flow injection chemiluminescence measurements. Talanta, 65( 4), 673-677. doi:10.1016/j.talanta.2005.03.021
    • NLM

      Rocha FRP, Ródenas-Torralba E, Reis BF dos, Morales-Rubio Á, Guardia M de la. A portable and low cost equipment for flow injection chemiluminescence measurements [Internet]. Talanta. 2005 ; 65( 4): 673-677.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2005.03.021
    • Vancouver

      Rocha FRP, Ródenas-Torralba E, Reis BF dos, Morales-Rubio Á, Guardia M de la. A portable and low cost equipment for flow injection chemiluminescence measurements [Internet]. Talanta. 2005 ; 65( 4): 673-677.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2005.03.021
  • Source: Talanta. Unidades: IQ, CENA

    Subjects: SEDIMENTOLOGIA, METAIS (ANÁLISE), QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      BARRETO, Sônia Regina Giancoli et al. Comparison of metal analysis in sediments using EDXRF and ICP-OES with the HCl and Tessie extraction methods. Talanta, v. 62, n. 2, p. 345-354, 2004Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2004.02.022. Acesso em: 09 jul. 2024.
    • APA

      Barreto, S. R. G., Nozaki, J., Oliveira, E. de, Nascimento Filho, V. F. do, Aragao, P. H. A., Scarminio, I. S., & Barreto, W. J. (2004). Comparison of metal analysis in sediments using EDXRF and ICP-OES with the HCl and Tessie extraction methods. Talanta, 62( 2), 345-354. doi:10.1016/j.talanta.2004.02.022
    • NLM

      Barreto SRG, Nozaki J, Oliveira E de, Nascimento Filho VF do, Aragao PHA, Scarminio IS, Barreto WJ. Comparison of metal analysis in sediments using EDXRF and ICP-OES with the HCl and Tessie extraction methods [Internet]. Talanta. 2004 ; 62( 2): 345-354.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.02.022
    • Vancouver

      Barreto SRG, Nozaki J, Oliveira E de, Nascimento Filho VF do, Aragao PHA, Scarminio IS, Barreto WJ. Comparison of metal analysis in sediments using EDXRF and ICP-OES with the HCl and Tessie extraction methods [Internet]. Talanta. 2004 ; 62( 2): 345-354.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.02.022
  • Source: Talanta. Unidade: IQ

    Subjects: ADSORÇÃO, QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ANTONIO, Patricia e IHA, Koshun e SUÁREZ-IHA, Maria Encarnación Vazquez. Adsorption of di-2-pyridyl ketone salicyloylhydrazone on silica gel: characteristics and isotherms. Talanta, v. 62, n. 2, p. 484-490, 2004Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2004.03.014. Acesso em: 09 jul. 2024.
    • APA

      Antonio, P., Iha, K., & Suárez-Iha, M. E. V. (2004). Adsorption of di-2-pyridyl ketone salicyloylhydrazone on silica gel: characteristics and isotherms. Talanta, 62( 2), 484-490. doi:10.1016/j.talanta.2004.03.014
    • NLM

      Antonio P, Iha K, Suárez-Iha MEV. Adsorption of di-2-pyridyl ketone salicyloylhydrazone on silica gel: characteristics and isotherms [Internet]. Talanta. 2004 ; 62( 2): 484-490.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.03.014
    • Vancouver

      Antonio P, Iha K, Suárez-Iha MEV. Adsorption of di-2-pyridyl ketone salicyloylhydrazone on silica gel: characteristics and isotherms [Internet]. Talanta. 2004 ; 62( 2): 484-490.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.03.014
  • Source: Talanta. Unidade: IQ

    Subjects: ABSORÇÃO, ESPECTROMETRIA, QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      OLIVEIRA, Adriana Paiva de et al. Use of the internal standardization for difficult sampling by graphite furnace atomic absorption spectrometry. Talanta, v. 64, n. 2, p. 334-337, 2004Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2004.02.032. Acesso em: 09 jul. 2024.
    • APA

      Oliveira, A. P. de, Gomes Neto, J. A., Nóbrega, J. de A., & Oliveira, P. V. de. (2004). Use of the internal standardization for difficult sampling by graphite furnace atomic absorption spectrometry. Talanta, 64( 2), 334-337. doi:10.1016/j.talanta.2004.02.032
    • NLM

      Oliveira AP de, Gomes Neto JA, Nóbrega J de A, Oliveira PV de. Use of the internal standardization for difficult sampling by graphite furnace atomic absorption spectrometry [Internet]. Talanta. 2004 ; 64( 2): 334-337.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.02.032
    • Vancouver

      Oliveira AP de, Gomes Neto JA, Nóbrega J de A, Oliveira PV de. Use of the internal standardization for difficult sampling by graphite furnace atomic absorption spectrometry [Internet]. Talanta. 2004 ; 64( 2): 334-337.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2004.02.032
  • Source: Talanta. Unidade: IQ

    Subjects: ESPECTROFOTOMETRIA (DETERMINAÇÃO), QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      LUPETTI, karina Omuro e ROCHA, Fábio Rodrigo Piovezani e FATIBELLO FILHO, Orlando. An improved flow system for phenols determination exploiting multicommutation and long pathlength spectrophotometry. Talanta, v. 62, n. 3, p. 463-467, 2004Tradução . . Disponível em: https://doi.org/10.1016/j.talanta.2003.08.018. Acesso em: 09 jul. 2024.
    • APA

      Lupetti, karina O., Rocha, F. R. P., & Fatibello Filho, O. (2004). An improved flow system for phenols determination exploiting multicommutation and long pathlength spectrophotometry. Talanta, 62( 3), 463-467. doi:10.1016/j.talanta.2003.08.018
    • NLM

      Lupetti karina O, Rocha FRP, Fatibello Filho O. An improved flow system for phenols determination exploiting multicommutation and long pathlength spectrophotometry [Internet]. Talanta. 2004 ; 62( 3): 463-467.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2003.08.018
    • Vancouver

      Lupetti karina O, Rocha FRP, Fatibello Filho O. An improved flow system for phenols determination exploiting multicommutation and long pathlength spectrophotometry [Internet]. Talanta. 2004 ; 62( 3): 463-467.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/j.talanta.2003.08.018
  • Source: Talanta. Unidade: IQ

    Subjects: ESPECTROFOTOMETRIA (DETERMINAÇÃO), QUÍMICA ANALÍTICA, SEDIMENTOLOGIA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      SILVA, Marcelo Solitrenick Pinto e GALHARDO, Cristiane Xavier e MASINI, Jorge Cesar. Application of sequential injection-mono segmented flow analysis (SI-MSFA) to spectrophotometric determination of sulfide in simulated waters-samples. Talanta, v. 60, n. 1, p. 45-52, 2003Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(03)00044-4. Acesso em: 09 jul. 2024.
    • APA

      Silva, M. S. P., Galhardo, C. X., & Masini, J. C. (2003). Application of sequential injection-mono segmented flow analysis (SI-MSFA) to spectrophotometric determination of sulfide in simulated waters-samples. Talanta, 60( 1), 45-52. doi:10.1016/s0039-9140(03)00044-4
    • NLM

      Silva MSP, Galhardo CX, Masini JC. Application of sequential injection-mono segmented flow analysis (SI-MSFA) to spectrophotometric determination of sulfide in simulated waters-samples [Internet]. Talanta. 2003 ; 60( 1): 45-52.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(03)00044-4
    • Vancouver

      Silva MSP, Galhardo CX, Masini JC. Application of sequential injection-mono segmented flow analysis (SI-MSFA) to spectrophotometric determination of sulfide in simulated waters-samples [Internet]. Talanta. 2003 ; 60( 1): 45-52.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(03)00044-4
  • Source: Talanta. Unidades: IQ, CENA

    Subjects: VITAMINAS, ESPECTROFOTOMETRIA (DETERMINAÇÃO), QUÍMICA ANALÍTICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ROCHA, Fábio Rodrigo Piovezani e FATIBELLO FILHO, Orlando e REIS, Boaventura Freire dos. A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations. Talanta, v. 59, n. 1, p. 191-200, 2003Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(02)00477-0. Acesso em: 09 jul. 2024.
    • APA

      Rocha, F. R. P., Fatibello Filho, O., & Reis, B. F. dos. (2003). A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations. Talanta, 59( 1), 191-200. doi:10.1016/s0039-9140(02)00477-0
    • NLM

      Rocha FRP, Fatibello Filho O, Reis BF dos. A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations [Internet]. Talanta. 2003 ; 59( 1): 191-200.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00477-0
    • Vancouver

      Rocha FRP, Fatibello Filho O, Reis BF dos. A multicommuted flow system for sequential spectrophotometric determination of hydrosoluble vitamins in pharmaceutical preparations [Internet]. Talanta. 2003 ; 59( 1): 191-200.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00477-0
  • Source: Talanta. Unidade: IQ

    Subjects: AMPEROMETRIA, QUÍMICA ANALÍTICA, SOLUÇÕES AQUOSAS, ELETROQUÍMICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      PEDROTTI, Jairo José e GUTZ, Ivano Gebhardt Rolf. Ultra-simple adaptor to convert batch cells with mercury drop electrodes in voltammetric detectors for flow analysis. Talanta, v. 60, n. 4, p. 695-705, 2003Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(03)00143-7. Acesso em: 09 jul. 2024.
    • APA

      Pedrotti, J. J., & Gutz, I. G. R. (2003). Ultra-simple adaptor to convert batch cells with mercury drop electrodes in voltammetric detectors for flow analysis. Talanta, 60( 4), 695-705. doi:10.1016/s0039-9140(03)00143-7
    • NLM

      Pedrotti JJ, Gutz IGR. Ultra-simple adaptor to convert batch cells with mercury drop electrodes in voltammetric detectors for flow analysis [Internet]. Talanta. 2003 ; 60( 4): 695-705.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(03)00143-7
    • Vancouver

      Pedrotti JJ, Gutz IGR. Ultra-simple adaptor to convert batch cells with mercury drop electrodes in voltammetric detectors for flow analysis [Internet]. Talanta. 2003 ; 60( 4): 695-705.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(03)00143-7
  • Source: Atmospheric Environment. Unidades: IQ, FMRP

    Subjects: QUÍMICA ANALÍTICA, QUÍMICA ATMOSFÉRICA, HIDROCARBONOS AROMÁTICOS, POLUIÇÃO ATMOSFÉRICA (ANÁLISE QUÍMICA), ESPECTROMETRIA DE MASSAS, MEIO AMBIENTE

    Acesso à fonteAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      DE MARTINIS, Bruno Spinosa et al. Polycyclic aromatic hydrocarbons in a bioassay-fractionated extract of PM10 collected in Sao Paulo, Brazil. Atmospheric Environment, v. 36, n. 2, p. 307-314, 2002Tradução . . Disponível em: https://doi.org/10.1016/s1352-2310(01)00334-x. Acesso em: 09 jul. 2024.
    • APA

      De Martinis, B. S., Okamoto, R. A., Kado, N. Y., Gundel, L. A., & Carvalho, L. R. F. de. (2002). Polycyclic aromatic hydrocarbons in a bioassay-fractionated extract of PM10 collected in Sao Paulo, Brazil. Atmospheric Environment, 36( 2), 307-314. doi:10.1016/s1352-2310(01)00334-x
    • NLM

      De Martinis BS, Okamoto RA, Kado NY, Gundel LA, Carvalho LRF de. Polycyclic aromatic hydrocarbons in a bioassay-fractionated extract of PM10 collected in Sao Paulo, Brazil [Internet]. Atmospheric Environment. 2002 ; 36( 2): 307-314.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s1352-2310(01)00334-x
    • Vancouver

      De Martinis BS, Okamoto RA, Kado NY, Gundel LA, Carvalho LRF de. Polycyclic aromatic hydrocarbons in a bioassay-fractionated extract of PM10 collected in Sao Paulo, Brazil [Internet]. Atmospheric Environment. 2002 ; 36( 2): 307-314.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s1352-2310(01)00334-x
  • Source: Talanta. Unidade: IQ

    Subjects: QUÍMICA ANALÍTICA, MÉTODO DE SEPARAÇÃO, REAÇÕES QUÍMICAS, ELETROQUÍMICA (ANÁLISE), VINHO (ANÁLISE QUÍMICA), ALIMENTOS (ANÁLISE QUÍMICA)

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ALIPÁZAGA, María V. et al. S(IV) induced autoxidation of 'CU'(II)/tetraglycine complexes in the presence of aldehydes: mechanistic considerations and analytical applications. Talanta, v. 57, n. 2, p. 375-381, 2002Tradução . . Acesso em: 09 jul. 2024.
    • APA

      Alipázaga, M. V., Kosminsky, L., Coichev, N., & Bertotti, M. (2002). S(IV) induced autoxidation of 'CU'(II)/tetraglycine complexes in the presence of aldehydes: mechanistic considerations and analytical applications. Talanta, 57( 2), 375-381.
    • NLM

      Alipázaga MV, Kosminsky L, Coichev N, Bertotti M. S(IV) induced autoxidation of 'CU'(II)/tetraglycine complexes in the presence of aldehydes: mechanistic considerations and analytical applications. Talanta. 2002 ; 57( 2): 375-381.[citado 2024 jul. 09 ]
    • Vancouver

      Alipázaga MV, Kosminsky L, Coichev N, Bertotti M. S(IV) induced autoxidation of 'CU'(II)/tetraglycine complexes in the presence of aldehydes: mechanistic considerations and analytical applications. Talanta. 2002 ; 57( 2): 375-381.[citado 2024 jul. 09 ]
  • Source: Talanta. Unidade: IQ

    Subjects: QUÍMICA ANALÍTICA, COBRE

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      QUINTINO, Maria do Socorro Maia et al. Amperometric determination of acetylsalicylic acid in drugs by batch injection analysis at a copper electrode in alkaline solutions. Talanta, v. 58, n. 5, p. 943-494, 2002Tradução . . Acesso em: 09 jul. 2024.
    • APA

      Quintino, M. do S. M., Corbo, D., Bertotti, M., & Angnes, L. (2002). Amperometric determination of acetylsalicylic acid in drugs by batch injection analysis at a copper electrode in alkaline solutions. Talanta, 58( 5), 943-494.
    • NLM

      Quintino M do SM, Corbo D, Bertotti M, Angnes L. Amperometric determination of acetylsalicylic acid in drugs by batch injection analysis at a copper electrode in alkaline solutions. Talanta. 2002 ; 58( 5): 943-494.[citado 2024 jul. 09 ]
    • Vancouver

      Quintino M do SM, Corbo D, Bertotti M, Angnes L. Amperometric determination of acetylsalicylic acid in drugs by batch injection analysis at a copper electrode in alkaline solutions. Talanta. 2002 ; 58( 5): 943-494.[citado 2024 jul. 09 ]
  • Source: Talanta. Unidade: IQ

    Subjects: ADSORÇÃO, QUÍMICA ANALÍTICA, METAIS

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ABATE, Gilberto e LICHTIG, Jaim e MASINI, Jorge Cesar. Construction and evaluation of a flow-through cell adapted to a commercial static mercury drop electrode (SMDE) to study the adsorption of Cd(II) and Pb(II) on vermiculite. Talanta, v. 58, n. 3, p. 433-443, 2002Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(02)00314-4. Acesso em: 09 jul. 2024.
    • APA

      Abate, G., Lichtig, J., & Masini, J. C. (2002). Construction and evaluation of a flow-through cell adapted to a commercial static mercury drop electrode (SMDE) to study the adsorption of Cd(II) and Pb(II) on vermiculite. Talanta, 58( 3), 433-443. doi:10.1016/s0039-9140(02)00314-4
    • NLM

      Abate G, Lichtig J, Masini JC. Construction and evaluation of a flow-through cell adapted to a commercial static mercury drop electrode (SMDE) to study the adsorption of Cd(II) and Pb(II) on vermiculite [Internet]. Talanta. 2002 ; 58( 3): 433-443.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00314-4
    • Vancouver

      Abate G, Lichtig J, Masini JC. Construction and evaluation of a flow-through cell adapted to a commercial static mercury drop electrode (SMDE) to study the adsorption of Cd(II) and Pb(II) on vermiculite [Internet]. Talanta. 2002 ; 58( 3): 433-443.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00314-4
  • Source: Spectrochimica Acta. Part B - Atomic Spectroscopy. Unidades: IQ, CENA

    Subjects: QUÍMICA ANALÍTICA, QUÍMICA INORGÂNICA, ESPECTROFOTOMETRIA, METAIS ALCALINOS, METAIS ALCALINOS TERROSOS, TUNGSTÊNIO, ESPECTROMETRIA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      QUEIROZ, Zilvanir Fernandes de et al. Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects. Spectrochimica Acta. Part B - Atomic Spectroscopy, v. 57, n. 1, p. 49-61, 2002Tradução . . Disponível em: https://doi.org/10.1016/s0584-8547(01)00350-0. Acesso em: 09 jul. 2024.
    • APA

      Queiroz, Z. F. de, Krug, F. J., Oliveira, P. V. de, Silva, M. M., & Nóbrega, J. de A. (2002). Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects. Spectrochimica Acta. Part B - Atomic Spectroscopy, 57( 1), 49-61. doi:10.1016/s0584-8547(01)00350-0
    • NLM

      Queiroz ZF de, Krug FJ, Oliveira PV de, Silva MM, Nóbrega J de A. Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects [Internet]. Spectrochimica Acta. Part B - Atomic Spectroscopy. 2002 ; 57( 1): 49-61.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0584-8547(01)00350-0
    • Vancouver

      Queiroz ZF de, Krug FJ, Oliveira PV de, Silva MM, Nóbrega J de A. Electrothermal behavior of sodium, potassium, calcium and magnesium in a tungsten coil atomizer and review of interfering effects [Internet]. Spectrochimica Acta. Part B - Atomic Spectroscopy. 2002 ; 57( 1): 49-61.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0584-8547(01)00350-0
  • Source: Talanta. Unidade: IQ

    Subjects: QUÍMICA ANALÍTICA, MANGANÊS, SELÊNIO, ESPECTROMETRIA, METABOLISMO, ESPECTROSCOPIA DE ABSORÇÃO ATÔMICA

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      CORREIA, Paulo Rogério Miranda e OLIVEIRA, Elisabeth de e OLIVEIRA, Pedro Vitoriano de. Simultaneous determination of manganese and selenium in serum by electrothermal atomic absorption spectrometry. Talanta, v. 57, n. 3, p. 527-535, 2002Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(02)00069-3. Acesso em: 09 jul. 2024.
    • APA

      Correia, P. R. M., Oliveira, E. de, & Oliveira, P. V. de. (2002). Simultaneous determination of manganese and selenium in serum by electrothermal atomic absorption spectrometry. Talanta, 57( 3), 527-535. doi:10.1016/s0039-9140(02)00069-3
    • NLM

      Correia PRM, Oliveira E de, Oliveira PV de. Simultaneous determination of manganese and selenium in serum by electrothermal atomic absorption spectrometry [Internet]. Talanta. 2002 ; 57( 3): 527-535.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00069-3
    • Vancouver

      Correia PRM, Oliveira E de, Oliveira PV de. Simultaneous determination of manganese and selenium in serum by electrothermal atomic absorption spectrometry [Internet]. Talanta. 2002 ; 57( 3): 527-535.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(02)00069-3
  • Source: Spectrochimica Acta. Part B - Atomic Spectroscopy. Unidade: IQ

    Subjects: QUÍMICA ANALÍTICA, ELETROQUÍMICA, ESPECTROMETRIA, MERCÚRIO (ELEMENTO QUÍMICO) (DETERMINAÇÃO), QUÍMICA AMBIENTAL, ABSORÇÃO

    Acesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MORENO, Ruben G. M. et al. An electrochemical flow-cell for permanent modification of graphite tube with palladium for mercury determination by electrothermal atomic absorption spectrometry. Spectrochimica Acta. Part B - Atomic Spectroscopy, v. 57, n. 4, p. 769-778, 2002Tradução . . Disponível em: https://doi.org/10.1016/s0584-8547(02)00009-5. Acesso em: 09 jul. 2024.
    • APA

      Moreno, R. G. M., Oliveira, E. de, Pedrotti, J. J., & Oliveira, P. V. de. (2002). An electrochemical flow-cell for permanent modification of graphite tube with palladium for mercury determination by electrothermal atomic absorption spectrometry. Spectrochimica Acta. Part B - Atomic Spectroscopy, 57( 4), 769-778. doi:10.1016/s0584-8547(02)00009-5
    • NLM

      Moreno RGM, Oliveira E de, Pedrotti JJ, Oliveira PV de. An electrochemical flow-cell for permanent modification of graphite tube with palladium for mercury determination by electrothermal atomic absorption spectrometry [Internet]. Spectrochimica Acta. Part B - Atomic Spectroscopy. 2002 ; 57( 4): 769-778.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0584-8547(02)00009-5
    • Vancouver

      Moreno RGM, Oliveira E de, Pedrotti JJ, Oliveira PV de. An electrochemical flow-cell for permanent modification of graphite tube with palladium for mercury determination by electrothermal atomic absorption spectrometry [Internet]. Spectrochimica Acta. Part B - Atomic Spectroscopy. 2002 ; 57( 4): 769-778.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0584-8547(02)00009-5
  • Source: Talanta. Unidade: IQ

    Assunto: QUÍMICA ANALÍTICA

    Acesso à fonteAcesso à fonteDOIHow to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      HIDALGO, Pilar e GUTZ, Ivano Gebhardt Rolf. Determination of low concentrations of the flotation reagent ethyl xanthate by sampled DC polarography and flow injection with amperometric detection. Talanta, v. 54, n. 2, p. 403-409, 2001Tradução . . Disponível em: https://doi.org/10.1016/s0039-9140(01)00311-3. Acesso em: 09 jul. 2024.
    • APA

      Hidalgo, P., & Gutz, I. G. R. (2001). Determination of low concentrations of the flotation reagent ethyl xanthate by sampled DC polarography and flow injection with amperometric detection. Talanta, 54( 2), 403-409. doi:10.1016/s0039-9140(01)00311-3
    • NLM

      Hidalgo P, Gutz IGR. Determination of low concentrations of the flotation reagent ethyl xanthate by sampled DC polarography and flow injection with amperometric detection [Internet]. Talanta. 2001 ; 54( 2): 403-409.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(01)00311-3
    • Vancouver

      Hidalgo P, Gutz IGR. Determination of low concentrations of the flotation reagent ethyl xanthate by sampled DC polarography and flow injection with amperometric detection [Internet]. Talanta. 2001 ; 54( 2): 403-409.[citado 2024 jul. 09 ] Available from: https://doi.org/10.1016/s0039-9140(01)00311-3

Digital Library of Intellectual Production of Universidade de São Paulo     2012 - 2024