Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT? (2021)
- Authors:
- Autor USP: SANTOS, CHRISTIANO DE OLIVEIRA - FORP
- Unidade: FORP
- DOI: 10.1007/s00784-021-03836-5
- Subjects: TOMOGRAFIA COMPUTADORIZADA DE EMISSÃO; IMPLANTES DENTÁRIOS; MANDÍBULA; DIAGNÓSTICO POR IMAGEM; ZIRCÔNIO
- Keywords: Artifacts; Cone-beam computed tomography; Dental implant; Zirconium
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Publisher place: Heidelberg
- Date published: 2021
- Source:
- Título: Clinical Oral Investigations
- ISSN: 1432-6981
- Volume/Número/Paginação/Ano: v. 25, n. 9, p. 5281-5291, 2021
- Este periódico é de acesso aberto
- Este artigo NÃO é de acesso aberto
-
ABNT
NASCIMENTO, Eduarda Helena Leandro et al. Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?. Clinical Oral Investigations, v. 25, n. 9, p. 5281-5291, 2021Tradução . . Disponível em: https://doi.org/10.1007/s00784-021-03836-5. Acesso em: 26 jan. 2026. -
APA
Nascimento, E. H. L., Gaêta-Araujo, H., Fontenele, R. C., Oliveira-Santos, N., Oliveira-Santos, C. de, & Freitas, D. Q. (2021). Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT? Clinical Oral Investigations, 25( 9), 5281-5291. doi:10.1007/s00784-021-03836-5 -
NLM
Nascimento EHL, Gaêta-Araujo H, Fontenele RC, Oliveira-Santos N, Oliveira-Santos C de, Freitas DQ. Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT? [Internet]. Clinical Oral Investigations. 2021 ; 25( 9): 5281-5291.[citado 2026 jan. 26 ] Available from: https://doi.org/10.1007/s00784-021-03836-5 -
Vancouver
Nascimento EHL, Gaêta-Araujo H, Fontenele RC, Oliveira-Santos N, Oliveira-Santos C de, Freitas DQ. Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT? [Internet]. Clinical Oral Investigations. 2021 ; 25( 9): 5281-5291.[citado 2026 jan. 26 ] Available from: https://doi.org/10.1007/s00784-021-03836-5 - Biometric parameters of the temporomandibular joint and association with disc displacement and pain: a magnetic resonance imaging study
- Optimization of tube current in cone-beam computed tomography for the detection of vertical root fractures with different intracanal materials
- Characterisation of additional mental foramina through cone beam computed tomography
- Association between the root canal configuration, endodontic treatment technical errors, and periapical hypodensities in molar teeth: a cone-beam computed tomographic study
- Avaliação da anatomia neurovascular da mandíbula por meio de tomografia computadorizada de feixe cônico
- Impact of micro-computed tomography reconstruction protocols on bone microarchitecture analysis
- Rare anatomical variation related to the nasopalatine canal
- Cone-beam computed tomography findings of impacted upper canines
- Effect of brightness and contrast variation for detectability of root resorption lesions in digital intraoral radiographs
- Detecção de fraturas radiculares verticais, na presença de pinos intrarradiculares de fibra de vidro e metálico, através da tomografia computadorizada de feixe cônico com diferentes parâmetros de miliamperagem
Informações sobre o DOI: 10.1007/s00784-021-03836-5 (Fonte: oaDOI API)
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| 003238439.pdf |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas