Finite element analysis applied to a metal-to-metal seal design (2020)
- Authors:
- Autor USP: LAMAS, WENDELL DE QUEIRÓZ - EEL
- Unidade: EEL
- DOI: 10.5419/bjpg2020-0013
- Assunto: MÉTODO DOS ELEMENTOS FINITOS
- Keywords: finite element analysis; finite-element model; geometry seals design and test; metal-to-metal seal gasket; sub-sea equipment
- Language: Inglês
- Abstract: This work presents the use of a finite element model software and suggests its use as a tool to develop metal-to-metal seals with the objective of reducing the number of designs and empirical tests, increasing possibility of success during validation tests, decreasing the number of repetitions of real tests needed, therefore, reducing execution costs. The present work configures a model of seal in a finite element analysis software and simulates different sizes of meshes to evaluate which configuration presented results and computational costs compatible with this work. Then, it develops different models in an interactive way, this is, it performs geometry changes with the intention of optimizing results. At the end of each model, it evaluates the results. This work develops and evaluates six models. At last, the authors selected the model which presented enough contact pressure to perform the sealing. This model presented a compatible stress in accordance with the failure criteria adopted, plastic strain in an acceptable range, and system behavior in accordance with that suggested by Sweeney, Brammer, and Chalmers (2004) in seal extremities.
- Imprenta:
- Source:
- Título: Brazilian journal of petroleum and gas
- ISSN: 1982-0593
- Volume/Número/Paginação/Ano: v.14, n.3, p.157-173, 2020
- Este periódico é de acesso aberto
- Este artigo NÃO é de acesso aberto
-
ABNT
LUCCI, Bruno Naressi et al. Finite element analysis applied to a metal-to-metal seal design. Brazilian journal of petroleum and gas, v. 14, n. 3, p. 157-173, 2020Tradução . . Disponível em: https://doi.org/10.5419/bjpg2020-0013. Acesso em: 14 fev. 2026. -
APA
Lucci, B. N., Lamas, W. D. Q., Grandinetti, F. J., & Giacaglia, G. E. O. (2020). Finite element analysis applied to a metal-to-metal seal design. Brazilian journal of petroleum and gas, 14( 3), 157-173. doi:10.5419/bjpg2020-0013 -
NLM
Lucci BN, Lamas WDQ, Grandinetti FJ, Giacaglia GEO. Finite element analysis applied to a metal-to-metal seal design [Internet]. Brazilian journal of petroleum and gas. 2020 ;14( 3): 157-173.[citado 2026 fev. 14 ] Available from: https://doi.org/10.5419/bjpg2020-0013 -
Vancouver
Lucci BN, Lamas WDQ, Grandinetti FJ, Giacaglia GEO. Finite element analysis applied to a metal-to-metal seal design [Internet]. Brazilian journal of petroleum and gas. 2020 ;14( 3): 157-173.[citado 2026 fev. 14 ] Available from: https://doi.org/10.5419/bjpg2020-0013 - Ensaio e avaliação por líquidos penetrantes em placas de bocais de elementos combustíveis na área nuclear
- Thermoeconomic and ecological analysis applied to heating industrial process in chemical reactors
- Energy, exergy and environmental analyses of hydrogen production process by ethanol steam reforming incorporated to sugar and alcohol mill
- Bancada Didática para Estudo de Sistema de Hidrociclone para Separação de Sólidos em Corrente Líquida
- Tribological study of a polymer bushing wear with a steel axle for an automatic car tensioner
- Modelo de cálculo analítico de ligações soldadas com base no método das tensões admissíveis em regime elástico linear / analytical calculation model of welded connections based on the permissible stress method in linear elastic range
- Energy balance analysis of the Brazilian alcohol for flex fuel production
- Ensaios não destrutivos para avaliação da rigidez em elementos de concreto armado / non-destructive tests for assessing stiffness in reinforced concrete elements
- Geração de Energia no Brasil: A Energia Solar Fotovoltaica como Instrumento na Redução de Custo
- Estudio técnico del uso de energía solar y biogás en vehículos eléctricos en Ilhabela, Brasil
Informações sobre o DOI: 10.5419/bjpg2020-0013 (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas