Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model (2024)
- Authors:
- Carvalho, Gabriela B. de O
- Caneo, Luiz Fernando
- Matte, Gregory
- Cruz, Caio Henrique de Almeida
- Silva, Everton Neri da
- Carletto, Luciana Pereira
- Castro, Ana Vitoria Cardoso Xavier
- Silva, Betina Gimenez Madueño
- Policarpo, Valéria Camargo
- Cestari, Idágene Aparecida
- Jatene, Fábio Biscegli
- Jatene, Marcelo Biscegli
- USP affiliated authors: CESTARI, IDÁGENE APARECIDA - EP ; JATENE, FABIO BISCEGLI - FM ; JATENE, MARCELO BISCEGLI - FM
- Unidades: EP; FM
- DOI: 10.21470/1678-9741-2023-0110
- Subjects: CIRURGIA TORÁCICA; CIRURGIA PEDIÁTRICA; CIRCULAÇÃO EXTRACORPÓREA; EQUIPAMENTOS E PROVISÕES HOSPITALARES
- Language: Inglês
- Imprenta:
- Source:
- Título: Brazilian journal of cardiovascular surgery
- ISSN: 0102-7638
- Volume/Número/Paginação/Ano: v. 39, n. 1, article ID e20230110, 9p, 2024
- Este periódico é de acesso aberto
- Este artigo é de acesso aberto
- URL de acesso aberto
- Cor do Acesso Aberto: gold
- Licença: cc-by
-
ABNT
CARVALHO, Gabriela B. de O et al. Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model. Brazilian journal of cardiovascular surgery, v. 39, n. 1, 2024Tradução . . Disponível em: https://observatorio.fm.usp.br/handle/OPI/57361. Acesso em: 04 ago. 2025. -
APA
Carvalho, G. B. de O., Caneo, L. F., Matte, G., Cruz, C. H. de A., Silva, E. N. da, Carletto, L. P., et al. (2024). Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model. Brazilian journal of cardiovascular surgery, 39( 1). doi:10.21470/1678-9741-2023-0110 -
NLM
Carvalho GB de O, Caneo LF, Matte G, Cruz CH de A, Silva EN da, Carletto LP, Castro AVCX, Silva BGM, Policarpo VC, Cestari IA, Jatene FB, Jatene MB. Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model [Internet]. Brazilian journal of cardiovascular surgery. 2024 ; 39( 1):[citado 2025 ago. 04 ] Available from: https://observatorio.fm.usp.br/handle/OPI/57361 -
Vancouver
Carvalho GB de O, Caneo LF, Matte G, Cruz CH de A, Silva EN da, Carletto LP, Castro AVCX, Silva BGM, Policarpo VC, Cestari IA, Jatene FB, Jatene MB. Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model [Internet]. Brazilian journal of cardiovascular surgery. 2024 ; 39( 1):[citado 2025 ago. 04 ] Available from: https://observatorio.fm.usp.br/handle/OPI/57361 - In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach
- Improving preoperative risk-of-death prediction in surgery congenital heart defects using artificial intelligence model: A pilot study
- Initial experience with del Nido cardioplegia solution at a pediatric and cngenital cardiac surgery Program in Brazil
- Functional performance of different venous limb options in simulated neonatal/pediatric cardiopulmonary bypass circuits
- Lessons Learned From a Critical Analysis of the Fontan Operation Over Three Decades in a Single Institution
- Atrioventricular Valve Repair in Single Ventricle Physiology: Timing Matters
- Impact of vacuum-assisted venous drainage on forward flow in simulated pediatric cardiopulmonary bypass circuits utilizing a centrifugal arterial pump head
- Early and Long-Term Outcomes of Surgical Treatment of Ebstein's Anomaly
- Myocardial tissue expression of mRNA and preoperative neutrophil-lymphocyte ratio in children undergoing congenital heart surgery
- Impacto da primeira onda da pandemia de COVID-19 na cirurgia cardiovascular no Brasil.[Carta]: análise de um Centro Terciário de Referência
Informações sobre o DOI: 10.21470/1678-9741-2023-0110 (Fonte: oaDOI API)
Download do texto completo
Tipo | Nome | Link | |
---|---|---|---|
Cestari-2024-Performance_... |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas