Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector (2019)
- Authors:
- USP affiliated authors: VIEIRA, MARCELO ANDRADE DA COSTA - EESC ; BORGES, LUCAS RODRIGUES - EESC ; BRANDÃO, RENANN DE FARIA - EESC ; VIMIEIRO, RODRIGO DE BARROS - EESC
- Unidade: EESC
- DOI: 10.29384/rbfm.2019.v13.n2.p30-34
- Subjects: MAMOGRAFIA; RAIOS X; PROCESSAMENTO DE IMAGENS; IMAGEM DIGITAL
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Source:
- Título: Revista Brasileira de Física Médica
- ISSN: 2176-8978
- Volume/Número/Paginação/Ano: v. 13, n. 2 , p. 30-34, 2019
- Status:
- Artigo publicado em periódico de acesso aberto (Gold Open Access)
- Versão do Documento:
- Versão publicada (Published version)
- Acessar versão aberta:
-
ABNT
BRANDÃO, Renann de Faria et al. Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector. Revista Brasileira de Física Médica, v. 13, n. 2 , p. 30-34, 2019Tradução . . Disponível em: http://dx.doi.org/10.29384/rbfm.2019.v13.n2.p30-34. Acesso em: 11 maio 2026. -
APA
Brandão, R. de F., Vimieiro, R. de B., Borges, L. R., Caron, R. F., & Vieira, M. A. da C. (2019). Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector. Revista Brasileira de Física Médica, 13( 2 ), 30-34. doi:10.29384/rbfm.2019.v13.n2.p30-34 -
NLM
Brandão R de F, Vimieiro R de B, Borges LR, Caron RF, Vieira MA da C. Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector [Internet]. Revista Brasileira de Física Médica. 2019 ; 13( 2 ): 30-34.[citado 2026 maio 11 ] Available from: http://dx.doi.org/10.29384/rbfm.2019.v13.n2.p30-34 -
Vancouver
Brandão R de F, Vimieiro R de B, Borges LR, Caron RF, Vieira MA da C. Evaluating the simulation of radiation dose reduction in a digital breast tomosynthesis system featuring an amorphous silicon (a-Si) detector [Internet]. Revista Brasileira de Física Médica. 2019 ; 13( 2 ): 30-34.[citado 2026 maio 11 ] Available from: http://dx.doi.org/10.29384/rbfm.2019.v13.n2.p30-34 - Open-source reconstruction toolbox for digital breast tomosynthesis
- Exploring the impact of image restoration in simulating higher dose mammography: effects on the detectability of microcalcifications across different sizes using model observer analysis
- Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis
- Bayesian reconstruction for digital breast tomosynthesis using a non-local Gaussian Markov random field a priori model
- Noise measurements from reconstructed digital breast tomosynthesis
- Noise models for virtual clinical trials of digital breast tomosynthesis
- Unbiased injection of signal-dependent noise in variance-stabilized range
- Noise modeling and variance stabilization of a computed radiography (CR) mammography system subject to fixed-pattern noise
- Denoising of mammograms subject to structural and spatially-correlated noise: a virtual clinical trial
- Transfer learning in deep convolutional neural networks for detection of architectural distortion in digital mammography
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
Por se tratar de integração com serviço externo, podem existir diferentes versões do trabalho (como preprints ou postprints), que podem diferir da versão publicada.
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| sysno3190339_artigo 07.pd... | Direct link |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas