Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation (2021)
- Authors:
- USP affiliated authors: LEONI, RENATA FERRANTI - FFCLRP ; PASCHOAL, ANDRÉ MONTEIRO - FMRP
- Unidades: FFCLRP; FMRP
- DOI: 10.1002/mrm.28807
- Subjects: ARTÉRIAS; CÉREBRO; DIAGNÓSTICO POR IMAGEM; FLUXO SANGUÍNEO
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Source:
- Título: Magnetic Resonance in Medicine
- ISSN: 0740-3194
- Volume/Número/Paginação/Ano: v. 86, n. 3, p. 1454-1462, 2021
- Status:
- Artigo aberto em periódico híbrido (Hybrid Open Access)
- Versão do Documento:
- Versão publicada (Published version)
- Acessar versão aberta:
-
ABNT
PASCHOAL, André Monteiro et al. Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation. Magnetic Resonance in Medicine, v. 86, n. 3, p. 1454-1462, 2021Tradução . . Disponível em: https://doi.org/10.1002/mrm.28807. Acesso em: 01 abr. 2026. -
APA
Paschoal, A. M., Leoni, R. F., Pastorello, B. F., & Osch, M. J. P. (2021). Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation. Magnetic Resonance in Medicine, 86( 3), 1454-1462. doi:10.1002/mrm.28807 -
NLM
Paschoal AM, Leoni RF, Pastorello BF, Osch MJP. Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation [Internet]. Magnetic Resonance in Medicine. 2021 ; 86( 3): 1454-1462.[citado 2026 abr. 01 ] Available from: https://doi.org/10.1002/mrm.28807 -
Vancouver
Paschoal AM, Leoni RF, Pastorello BF, Osch MJP. Three‐dimensional gradient and spin‐echo readout for time‐encoded pseudo‐continuous arterial spin labeling: Influence of segmentation factor and flow compensation [Internet]. Magnetic Resonance in Medicine. 2021 ; 86( 3): 1454-1462.[citado 2026 abr. 01 ] Available from: https://doi.org/10.1002/mrm.28807 - Gaussian mixture for peak identification in non-negative least squares fitting of the IVIM signal
- The utility of IVIM maps in the assessment of microvascular perfusion of brain glioma
- Brain connectivity assessment between rest condition and verbal fluency task through arterial spin labeling
- Regularized nonnegative least-square fitting for intravoxel incoherent motion data processing: a simulation study
- Dual-echo arterial spin labeling for brain perfusion quantification and functional analysis
- Otimização do contraste em Arterial Spin Labeling multifase
- Optimization and application of quantitative magnetic resonance imaging methods to analyze brain perfusion and function
- Evaluation of removing residual motion artifacts and global signal fluctuations in functional arterial spin labeling data
- Simulações hemodinâmicas por meio de imagens de ressonância magnética em artérias
- Hemodinâmica computacional em artérias utilizando imagens de ressonância magnética
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
Por se tratar de integração com serviço externo, podem existir diferentes versões do trabalho (como preprints ou postprints), que podem diferir da versão publicada.
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
