Pump-free microfluidic rapid mixer combined with a paper-based channel (2020)
- Authors:
- USP affiliated authors: OLIVEIRA, ANDERSON RODRIGO MORAES DE - FFCLRP ; CARRÃO, DANIEL BLASCKE - FFCLRP
- Unidade: FFCLRP
- DOI: 10.1021/acssensors.0c00937
- Subjects: MISTURADORES; PESTICIDAS; INIBIDORES DE ENZIMAS
- Keywords: Capillary-driven microfluidic; Passive mixer; Pesticide; Colorimetric enzymatic inhibition assay; Onsite analysis
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Publisher place: Washington
- Date published: 2020
- Source:
- Título: ACS Sensors
- ISSN: 2379-3694
- Volume/Número/Paginação/Ano: v. 5, p. 2230-2238, 2020
- Status:
- Artigo possui versão em acesso aberto em repositório (Green Open Access)
- Versão do Documento:
- Versão submetida (Pré-print)
- Acessar versão aberta:
-
ABNT
JANG, Ilhoon et al. Pump-free microfluidic rapid mixer combined with a paper-based channel. ACS Sensors, v. 5, p. 2230-2238, 2020Tradução . . Disponível em: https://doi.org/10.1021/acssensors.0c00937. Acesso em: 30 mar. 2026. -
APA
Jang, I., Carrão, D. B., Menger, R. F., Oliveira, A. R. M. de, & Henry, C. S. (2020). Pump-free microfluidic rapid mixer combined with a paper-based channel. ACS Sensors, 5, 2230-2238. doi:10.1021/acssensors.0c00937 -
NLM
Jang I, Carrão DB, Menger RF, Oliveira ARM de, Henry CS. Pump-free microfluidic rapid mixer combined with a paper-based channel [Internet]. ACS Sensors. 2020 ; 5 2230-2238.[citado 2026 mar. 30 ] Available from: https://doi.org/10.1021/acssensors.0c00937 -
Vancouver
Jang I, Carrão DB, Menger RF, Oliveira ARM de, Henry CS. Pump-free microfluidic rapid mixer combined with a paper-based channel [Internet]. ACS Sensors. 2020 ; 5 2230-2238.[citado 2026 mar. 30 ] Available from: https://doi.org/10.1021/acssensors.0c00937 - Challenges of probe cocktail approach for human drug-drug interaction assays. [Editorial]
- Enantioseparation of pesticides: a critical review
- Evaluation of the enantioselective in vitro metabolism of the chiral pesticide fipronil employing a human model: risk assessment through in vitro-in vivo correlation and prediction of toxicokinetic parameters
- Enantioselective in vitro metabolism and in vitro-in vivo correlation of the herbicide ethofumesate in a human model
- Design and application of a self-pumping microfluidic staggered herringbone mixer
- Emerging applications of paper-based analytical devices for drug analysis: a review
- A review of analytical methods for codeine determination
- Estudo de metabolismo in vitro do componente majoritário da própolis verde brasileira, Artepelin C, empregando microssomas hepáticos
- Capillary electrophoresis and holow fiber-liquid phase microextraction for the stereoselective analysis of abendazole metabolites after fungal biotransformation
- Metabolism studies of chiral pesticides: a critical review
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
Por se tratar de integração com serviço externo, podem existir diferentes versões do trabalho (como preprints ou postprints), que podem diferir da versão publicada.
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| 003040581.pdf |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
