Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform (2020)
- Authors:
- USP affiliated authors: MONARO, RENATO MACHADO - EP ; COURY, DENIS VINICIUS - EESC ; FREITAS, VINÍCIUS ALBERNAZ LACERDA - EESC
- Unidades: EP; EESC
- DOI: 10.1049/iet-gtd.2019.1551
- Subjects: PROTEÇÃO DE SISTEMAS ELÉTRICOS; ALTA TENSÃO; TRANSFORMADA DE HILBERT; ENGENHARIA ELÉTRICA
- Language: Inglês
- Imprenta:
- Publisher place: Stevenage, United Kingdom
- Date published: 2020
- Source:
- Título: IET Generation, Transmission and Distribution
- ISSN: 1751-8687
- Volume/Número/Paginação/Ano: v. 14, n. 15, p. 3022-3032, 2020
- Status:
- Artigo possui acesso gratuito no site do editor (Bronze Open Access)
- Versão do Documento:
- Versão publicada (Published version)
- Acessar versão aberta:
-
ABNT
FREITAS, Vinícius Albernaz Lacerda et al. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform. IET Generation, Transmission and Distribution, v. 14, n. 15, p. 3022-3032, 2020Tradução . . Disponível em: https://doi.org/10.1049/iet-gtd.2019.1551. Acesso em: 02 abr. 2026. -
APA
Freitas, V. A. L., Monaro, R. M., Campos-Gaona, D., Coury, D. V., & Anaya-Lara, O. (2020). Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform. IET Generation, Transmission and Distribution, 14( 15), 3022-3032. doi:10.1049/iet-gtd.2019.1551 -
NLM
Freitas VAL, Monaro RM, Campos-Gaona D, Coury DV, Anaya-Lara O. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform [Internet]. IET Generation, Transmission and Distribution. 2020 ; 14( 15): 3022-3032.[citado 2026 abr. 02 ] Available from: https://doi.org/10.1049/iet-gtd.2019.1551 -
Vancouver
Freitas VAL, Monaro RM, Campos-Gaona D, Coury DV, Anaya-Lara O. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform [Internet]. IET Generation, Transmission and Distribution. 2020 ; 14( 15): 3022-3032.[citado 2026 abr. 02 ] Available from: https://doi.org/10.1049/iet-gtd.2019.1551 - Fault distance estimation in multiterminal HVDC systems using the Lomb-Scargle periodogram
- The influence of grounding configuration in a full conversion wind generator under internal faults
- Signal processing techniques for synchrophasors considering short‐circuit signals: a comparative study
- Recursive and non-recursive algorithms for power system real time phasor estimations
- LCL filter design for VSC-HVDC systems supplying passive grids
- An intelligent relay based on fuzzy logic applied to differential protection of synchronous generators
- Proportional-resonant controller applied to modular multilevel converter for HVDC systems
- Short-circuit analytical model for modular multilevel converters considering DC cable capacitance
- Control-based fault current limiter for modular multilevel voltage-source converters
- Multi-objective PSO for control-loop tuning of DFIG wind turbines with chopper protection and reactive-current injection
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
Por se tratar de integração com serviço externo, podem existir diferentes versões do trabalho (como preprints ou postprints), que podem diferir da versão publicada.
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| iet-gtd.2019.1551.pdf | Direct link |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas