Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform (2020)
- Authors:
- USP affiliated authors: MONARO, RENATO MACHADO - EP ; COURY, DENIS VINICIUS - EESC ; FREITAS, VINÍCIUS ALBERNAZ LACERDA - EESC
- Unidades: EP; EESC
- DOI: 10.1049/iet-gtd.2019.1551
- Subjects: PROTEÇÃO DE SISTEMAS ELÉTRICOS; ALTA TENSÃO; TRANSFORMADA DE HILBERT; ENGENHARIA ELÉTRICA
- Language: Inglês
- Imprenta:
- Publisher place: Stevenage, United Kingdom
- Date published: 2020
- Source:
- Título: IET Generation, Transmission and Distribution
- ISSN: 1751-8687
- Volume/Número/Paginação/Ano: v. 14, n. 15, p. 3022-3032, 2020
- Este periódico é de assinatura
- Este artigo é de acesso aberto
- URL de acesso aberto
- Cor do Acesso Aberto: green
-
ABNT
FREITAS, Vinícius Albernaz Lacerda et al. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform. IET Generation, Transmission and Distribution, v. 14, n. 15, p. 3022-3032, 2020Tradução . . Disponível em: https://doi.org/10.1049/iet-gtd.2019.1551. Acesso em: 28 dez. 2025. -
APA
Freitas, V. A. L., Monaro, R. M., Campos-Gaona, D., Coury, D. V., & Anaya-Lara, O. (2020). Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform. IET Generation, Transmission and Distribution, 14( 15), 3022-3032. doi:10.1049/iet-gtd.2019.1551 -
NLM
Freitas VAL, Monaro RM, Campos-Gaona D, Coury DV, Anaya-Lara O. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform [Internet]. IET Generation, Transmission and Distribution. 2020 ; 14( 15): 3022-3032.[citado 2025 dez. 28 ] Available from: https://doi.org/10.1049/iet-gtd.2019.1551 -
Vancouver
Freitas VAL, Monaro RM, Campos-Gaona D, Coury DV, Anaya-Lara O. Distance protection algorithm for multiterminal HVDC systems using the Hilbert–Huang transform [Internet]. IET Generation, Transmission and Distribution. 2020 ; 14( 15): 3022-3032.[citado 2025 dez. 28 ] Available from: https://doi.org/10.1049/iet-gtd.2019.1551 - Fault distance estimation in multiterminal HVDC systems using the Lomb-Scargle periodogram
- Signal processing techniques for synchrophasors considering short‐circuit signals: a comparative study
- The influence of grounding configuration in a full conversion wind generator under internal faults
- An intelligent relay based on fuzzy logic applied to differential protection of synchronous generators
- Proportional-resonant controller applied to modular multilevel converter for HVDC systems
- LCL filter design for VSC-HVDC systems supplying passive grids
- LCL filter design for VSC-HVDC systems supplying passive grids
- Differential protection for stator ground faults in a full-converter wind turbine generator
- Recursive and non-recursive algorithms for power system real time phasor estimations
- Wind generator protection with ESSs considering grid connected and island mode operations
Informações sobre o DOI: 10.1049/iet-gtd.2019.1551 (Fonte: oaDOI API)
Download do texto completo
| Tipo | Nome | Link | |
|---|---|---|---|
| iet-gtd.2019.1551.pdf | Direct link |
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas