Preloaded catheters and guide-wire systems to facilitate catheterization during fenestrated and branched endovascular aortic repair (2019)
- Authors:
- USP affiliated author: RIBEIRO, MAURÍCIO SERRA - FMRP
- School: FMRP
- DOI: 10.1007/s00270-019-02322-6
- Subjects: AORTA ABDOMINAL; ANEURISMA AÓRTICO
- Keywords: Fenestrated and branched endovascular repair; Preloaded catheter; Complex aortic aneurysm; Thoracoabdominal aortic aneurysm
- Language: Inglês
- Imprenta:
- Source:
- Título do periódico: CardioVascular and Interventional Radiology
- ISSN: 0174-1551
- Volume/Número/Paginação/Ano: v. 42, n. 12, p. 1678-1686, 2019
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
CHINI, Julia et al. Preloaded catheters and guide-wire systems to facilitate catheterization during fenestrated and branched endovascular aortic repair. CardioVascular and Interventional Radiology, v. 42, n. 12, p. 1678-1686, 2019Tradução . . Disponível em: https://doi.org/10.1007/s00270-019-02322-6. Acesso em: 29 jun. 2022. -
APA
Chini, J., Mendes, B. C., Tenorio, E. R., Ribeiro, M. S., Sandri, G. A., Cha, S., et al. (2019). Preloaded catheters and guide-wire systems to facilitate catheterization during fenestrated and branched endovascular aortic repair. CardioVascular and Interventional Radiology, 42( 12), 1678-1686. doi:10.1007/s00270-019-02322-6 -
NLM
Chini J, Mendes BC, Tenorio ER, Ribeiro MS, Sandri GA, Cha S, Hofer J, Oderich GS. Preloaded catheters and guide-wire systems to facilitate catheterization during fenestrated and branched endovascular aortic repair [Internet]. CardioVascular and Interventional Radiology. 2019 ; 42( 12): 1678-1686.[citado 2022 jun. 29 ] Available from: https://doi.org/10.1007/s00270-019-02322-6 -
Vancouver
Chini J, Mendes BC, Tenorio ER, Ribeiro MS, Sandri GA, Cha S, Hofer J, Oderich GS. Preloaded catheters and guide-wire systems to facilitate catheterization during fenestrated and branched endovascular aortic repair [Internet]. CardioVascular and Interventional Radiology. 2019 ; 42( 12): 1678-1686.[citado 2022 jun. 29 ] Available from: https://doi.org/10.1007/s00270-019-02322-6 - Energy performance and greenhouse gas emissions of kelp cultivation for biogas and fertilizer recovery in Sweden
- Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and thoracoabdominal aortic aneurysms
- Impact of aortic wall thrombus on late changes in renal function among patients treated by fenestrated-branched endografts
- Assessment of aortic wall thrombus predicts outcomes of endovascular repair of complex aortic aneurysms using fenestrated and branched endografts
- Endovascular repair of thoracoabdominal aortic aneurysms using fenestrated and branched endografts
- Off-the-shelf fenestrated and branched stent graft designs for abdominal aortic aneurysm repair
- Prospective, nonrandomized study to evaluate endovascular repair of pararenal and thoracoabdominal aortic aneurysms using fenestrated-branched endografts based on supraceliac sealing zones
- Assessment of aortic wall thrombus predicts outcomes of endovascular repair of complex aortic aneurysms using fenestrated and branched endografts
- Caracterização do perfil dos componentes do sistema das cininas, óxido nítrico e metaloproteinases como marcadores na restenose de stents pós angioplastia percutânea transluminal periférica
- MicroRNAs and current concepts on the pathogenesis of abdominal aortic aneurysm
Informações sobre o DOI: 10.1007/s00270-019-02322-6 (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
Referências citadas na obra
Oderich GS, Ribeiro M, Hofer J, Wigham J, Cha S, Chini J, et al. Prospective, nonrandomized study to evaluate endovascular repair of pararenal and thoracoabdominal aortic aneurysms using fenestrated–branched endografts based on supraceliac sealing zones. J Vasc Surg. 2017;65(5):1249–59 e10. |
---|
Mastracci TM, Greenberg RK, Eagleton MJ, Hernandez AV. Durability of branches in branched and fenestrated endografts. J Vasc Surg. 2013;57(4):926–33. |
Oderich GS, Greenberg RK, Farber M, Lyden S, Sanchez L, Fairman R, et al. Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms. J Vasc Surg. 2014;60(6):1420–8 e5. |
Verhoeven E, Katsargyris A, Oikonomou K, Kouvelos G, Renner H, Ritter W. Fenestrated endovascular aortic aneurysm repair as a first line treatment option to treat short necked, juxtarenal, and suprarenal aneurysms. Eur J Vasc Endovasc Surg. 2016;51(6):775–81. |
Maurel B, Delclaux N, Sobocinski J, Hertault A, Martin-Gonzalez T, Moussa M, et al. Editor’s choice—the impact of early pelvic and lower limb reperfusion and attentive peri-operative management on the incidence of spinal cord ischemia during thoracoabdominal aortic aneurysm endovascular repair. Eur J Vasc Endovasc Surg. 2015;49(3):248–54. |
Banga PV, Oderich GS, Reis de Souza L, Hofer J, Cazares Gonzalez ML, Pulido JN, et al. Neuromonitoring, cerebrospinal fluid drainage, and selective use of iliofemoral conduits to minimize risk of spinal cord injury during complex endovascular aortic repair. J Endovasc Ther. 2016;23(1):139–49. |
Etz CD, Kari FA, Mueller CS, Silovitz D, Brenner RM, Lin H-M, et al. The collateral network concept: a reassessment of the anatomy of spinal cord perfusion. J Thorac Cardiovasc Surg. 2011;141(4):1020–8. |
Tenorio ER, Eagleton MJ, Kärkkäinen JM, Oderich GS. Prevention of spinal cord injury during endovascular thoracoabdominal repair. J Cardiovasc Surg. 2019;60(1):54–65. |
Oderich GS, Mendes BC, Correa MP. Preloaded guidewires to facilitate endovascular repair of thoracoabdominal aortic aneurysm using a physician-modified branched stent graft. J Vasc Surg. 2014;59(4):1168–73. |
Manning BJ, Harris PL, Hartley DE, Ivancev K. Preloaded fenestrated stent-grafts for the treatment of juxtarenal aortic aneurysms. J Endovasc Ther. 2010;17(4):449–55. |
Verhoeven EL. The first phase of another exciting chapter in the development of fenestrated stent-grafts: preloaded devices. J Endovasc Ther. 2010;17(4):456. |
Chaikof EL, Blankensteijn JD, Harris PL, White GH, Zarins CK, Bernhard VM, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002;35(5):1048–60. |
Fillinger MF, Greenberg RK, McKinsey JF, Chaikof EL. Reporting standards for thoracic endovascular aortic repair (TEVAR). J Vasc Surg. 2010;52(4):1022–33 e5. |
Eagleton MJ, Follansbee M, Wolski K, Mastracci T, Kuramochi Y. Fenestrated and branched endovascular aneurysm repair outcomes for type II and III thoracoabdominal aortic aneurysms. J Vasc Surg. 2016;63(4):930–42. |
Katsargyris A, Oikonomou K, Kouvelos G, Mufty H, Ritter W, Verhoeven EL. Comparison of outcomes for double fenestrated endovascular aneurysm repair versus triple or quadruple fenestrated endovascular aneurysm repair in the treatment of complex abdominal aortic aneurysms. J Vasc Surg. 2017;66(1):29–36. |
Eagleton MJ, Shah S, Petkosevek D, Mastracci TM, Greenberg RK. Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endografting. J Vasc Surg. 2014;59(1):89–95. |
Fiorucci B, Kölbel T, Rohlffs F, Heidemann F, Debus SE, Tsilimparis N. Right brachial access is safe for branched endovascular aneurysm repair in complex aortic disease. J Vasc Surg. 2017;66(2):360–6. |
Ribeiro M, Oderich GS, Macedo T, Vrtiska TJ, Hofer J, Chini J, et al. Assessment of aortic wall thrombus predicts outcomes of endovascular repair of complex aortic aneurysms using fenestrated and branched endografts. J Vasc Surg. 2017;66(5):1321–33. |
Mirza AK, Oderich GS, Sandri GA, Tenorio ER, Davila VJ, Kärkkäinen JM, et al. Outcomes of upper extremity access during fenestrated–branched endovascular aortic repair. J Vasc Surg. 2019;69(3):635–43. |