EM Fields Generated by a Scale Model Helical Antenna and Its Use in Validating a Code for Lightning-Induced Voltage Calculation (2019)
- Authors:
- Autor USP: PIANTINI, ALEXANDRE - IEE
- Unidade: IEE
- DOI: 10.1109/TEMC.2019.2911995
- Subjects: DESCARGA ATMOSFÉRICA; CAMPO ELETROMAGNÉTICO
- Language: Inglês
- Imprenta:
- Publisher place: Piscataway
- Date published: 2019
- Source:
- Título: IEEE Transactions on Electromagnetic Compatibility
- Volume/Número/Paginação/Ano: v.61, n.3,p.778-787, Jun.2019
- Este periódico é de acesso aberto
- Este artigo NÃO é de acesso aberto
-
ABNT
BRIGNONE, Massimo et al. EM Fields Generated by a Scale Model Helical Antenna and Its Use in Validating a Code for Lightning-Induced Voltage Calculation. IEEE Transactions on Electromagnetic Compatibility, v. 61, n. Ju2019, p. 778-787, 2019Tradução . . Disponível em: https://doi.org/10.1109/TEMC.2019.2911995. Acesso em: 30 jan. 2026. -
APA
Brignone, M., Mestriner, D., Procopio, R., Rossi, M., Piantini, A., & Rachidi, F. (2019). EM Fields Generated by a Scale Model Helical Antenna and Its Use in Validating a Code for Lightning-Induced Voltage Calculation. IEEE Transactions on Electromagnetic Compatibility, 61( Ju2019), 778-787. doi:10.1109/TEMC.2019.2911995 -
NLM
Brignone M, Mestriner D, Procopio R, Rossi M, Piantini A, Rachidi F. EM Fields Generated by a Scale Model Helical Antenna and Its Use in Validating a Code for Lightning-Induced Voltage Calculation [Internet]. IEEE Transactions on Electromagnetic Compatibility. 2019 ;61( Ju2019):778-787.[citado 2026 jan. 30 ] Available from: https://doi.org/10.1109/TEMC.2019.2911995 -
Vancouver
Brignone M, Mestriner D, Procopio R, Rossi M, Piantini A, Rachidi F. EM Fields Generated by a Scale Model Helical Antenna and Its Use in Validating a Code for Lightning-Induced Voltage Calculation [Internet]. IEEE Transactions on Electromagnetic Compatibility. 2019 ;61( Ju2019):778-787.[citado 2026 jan. 30 ] Available from: https://doi.org/10.1109/TEMC.2019.2911995 - Evaluation of lightning-related faults that lead to distribution networkoutages: An experimental case study
- Lightning-Induced Voltages on Complex Power Systems by Using CiLIV: The Effects of Channel Tortuosity
- Evaluation of models for representing usual grounding electrode configurations of distribution lines in Brazil
- Lightning performance studies for a 13,8 kV distribution network
- Inevitáveis e perigosas[Depoimento à Anna Flávia Rochas]
- O Raio, esse desconhecido [Entrevista]
- Sobretensões atmosféricas em redes de baixa tensão
- Lightning transients on LV networks caused by indirect strokes
- Custos relativos a descargas atmosféricas em sistemas de distribuição de energia
- Guest Editorial Special Section ''Advances in Lightning Modeling, Computation, and Measurement''
Informações sobre o DOI: 10.1109/TEMC.2019.2911995 (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas