Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique (2017)
- Authors:
- USP affiliated authors: PAVONI, JULIANA FERNANDES - FFCLRP ; BAFFA FILHO, OSWALDO - FFCLRP
- Unidade: FFCLRP
- DOI: 10.1002/mp.12400
- Subjects: FÍSICA; RADIOTERAPIA; DOSIMETRIA; DOSÍMETROS
- Keywords: Alanine; Gel dosimetry; MAGIC-f; Tridimensional dosimetry; VMAT
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Source:
- Título: Medical Physics
- ISSN: 0094-2405
- Volume/Número/Paginação/Ano: v. 44, n. 9, p. 4869-4879, 2017
- Status:
- Artigo possui versão em acesso aberto em repositório (Green Open Access)
- Versão do Documento:
- Versão publicada (Published version)
- Acessar versão aberta:
-
ABNT
PAVONI, Juliana Fernandes et al. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique. Medical Physics, v. 44, n. 9, p. 4869-4879, 2017Tradução . . Disponível em: https://doi.org/10.1002/mp.12400. Acesso em: 09 abr. 2026. -
APA
Pavoni, J. F., Neves-Junior, W. F. P., Silveira, M. A. da, Haddad, C. M. K., & Baffa, O. (2017). Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique. Medical Physics, 44( 9), 4869-4879. doi:10.1002/mp.12400 -
NLM
Pavoni JF, Neves-Junior WFP, Silveira MA da, Haddad CMK, Baffa O. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique [Internet]. Medical Physics. 2017 ; 44( 9): 4869-4879.[citado 2026 abr. 09 ] Available from: https://doi.org/10.1002/mp.12400 -
Vancouver
Pavoni JF, Neves-Junior WFP, Silveira MA da, Haddad CMK, Baffa O. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique [Internet]. Medical Physics. 2017 ; 44( 9): 4869-4879.[citado 2026 abr. 09 ] Available from: https://doi.org/10.1002/mp.12400 - Tridimentional dosimetry for IMRT treatment using gel magic-f by MRI
- Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry
- Characteristics of modified radiochomic gel Turnbull-Blue
- 3D dosimetric evaluation of breast cancer treatments using 3D conformational technique, direct IMRT and inverse IMRT in the presence of a simulated respiratory movement
- The use of MAGIC-f gel to perform RTP clinical checks, a first approach
- Comparação do controle de qualidade de tratamentos com radioterapia de intensidade modulada para tumores de próstata usando dosimetria gel tridimensional com a dosimetria convencional usando a medida de dose pontual e bidimensional
- What happens when spins meet for ionizing radiation dosimetry?
- A phantom to study the effects of metallic prostheses in radiotherapy by gel dosimetry
- Feasibility on using composite gel-alanine dosimetry on the validation of a multiple brain metastasis radiosurgery VMAT technique
- Feasibility on using composite gel-alanine dosimetry on the validation of a multiple brain metastasis radiosurgery VMAT technique
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
Por se tratar de integração com serviço externo, podem existir diferentes versões do trabalho (como preprints ou postprints), que podem diferir da versão publicada.
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas