Characterization of resolution, sensitivity, and shielding of a gamma-probe for sentinel lymph node localization: an experimental study (2017)
- Authors:
- USP affiliated authors: ANA, LAURO WICHERT - FMRP ; MORAES, EDER REZENDE - FFCLRP
- Unidades: FMRP; FFCLRP
- DOI: 10.1097/MNM.0000000000000725
- Subjects: FÍSICA MÉDICA; MEDICINA NUCLEAR; CONTROLE DA QUALIDADE
- Keywords: Collimation; Health physics; Nuclear medicine; Quality control; Resolution; Sensitivity; Sentinel lymph node
- Agências de fomento:
- Language: Inglês
- Imprenta:
- Source:
- Título do periódico: Nuclear Medicine Communications
- ISSN: 0143-3636
- Volume/Número/Paginação/Ano: v. 38, n. 10, p. 837-842, 2017
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
ITIKAWA, Emerson N. et al. Characterization of resolution, sensitivity, and shielding of a gamma-probe for sentinel lymph node localization: an experimental study. Nuclear Medicine Communications, v. 38, n. 10, p. 837-842, 2017Tradução . . Disponível em: https://doi.org/10.1097/MNM.0000000000000725. Acesso em: 19 set. 2024. -
APA
Itikawa, E. N., Santos, L. A., Trevisan, A. C., Pitella, F. A., Kato, M., Moraes, E. R., & Wichert-Ana, L. (2017). Characterization of resolution, sensitivity, and shielding of a gamma-probe for sentinel lymph node localization: an experimental study. Nuclear Medicine Communications, 38( 10), 837-842. doi:10.1097/MNM.0000000000000725 -
NLM
Itikawa EN, Santos LA, Trevisan AC, Pitella FA, Kato M, Moraes ER, Wichert-Ana L. Characterization of resolution, sensitivity, and shielding of a gamma-probe for sentinel lymph node localization: an experimental study [Internet]. Nuclear Medicine Communications. 2017 ; 38( 10): 837-842.[citado 2024 set. 19 ] Available from: https://doi.org/10.1097/MNM.0000000000000725 -
Vancouver
Itikawa EN, Santos LA, Trevisan AC, Pitella FA, Kato M, Moraes ER, Wichert-Ana L. Characterization of resolution, sensitivity, and shielding of a gamma-probe for sentinel lymph node localization: an experimental study [Internet]. Nuclear Medicine Communications. 2017 ; 38( 10): 837-842.[citado 2024 set. 19 ] Available from: https://doi.org/10.1097/MNM.0000000000000725 - Ausculta digital abdominal
- Towards component-based validation of GATE: aspects of the coincidence processor
- Influência do repouso e alongamento na atividade elétrica muscular após digitação
- Comparação das freqüências de vibração geradas nos aparelhos Flutter VRP1 e shaker utilizados na terapia de higiene brônquica
- Estudos biofísicos da eletrofisiologia gástrica
- Construcao e aplicacoes de um biogradiometro monocanal com um squid dc
- A composição de fibras musculares pelo teste de potência Flegner em corredores fundistas, meio-fundistas e velocistas
- Nuclear medicine therapy: past or future
- Estudo para o desenvolvimento de um fantoma para aplicação em estudos de SPECT e PET cerebral
- Estudo do desempenho de um sistema de tomografia PET com diferentes geometrias
Informações sobre o DOI: 10.1097/MNM.0000000000000725 (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas