Evaluating the potential, applicability, and effectiveness of ozone sterilization process for medical devices (2018)

  • Authors:
  • USP affiliated authors: LOURENÇO, FELIPE REBELLO - FCF ; KIKUCHI, IRENE SATIKO - FCF ; PINTO, TEREZINHA DE JESUS ANDREOLI - FCF
  • Unidades: FCF; FCF; FCF
  • DOI: 10.1007/s12247-017-9308-7
  • Subjects: OZÔNIO; ESTERILIZAÇÃO
  • Language: Inglês
  • Imprenta:
  • Source:
  • Online source accessDOI
    Informações sobre o DOI: 10.1007/s12247-017-9308-7 (Fonte: oaDOI API)
    • Este periódico é de assinatura
    • Este artigo NÃO é de acesso aberto
    • Cor do Acesso Aberto: closed

    How to cite
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas

    • ABNT

      ALMEIDA, Túlia de Souza Botelho; LOURENÇO, Felipe Rebello; KIKUCHI, Irene Satiko; et al. Evaluating the potential, applicability, and effectiveness of ozone sterilization process for medical devices. Journal of Pharmaceutical Innovation, New York, v. 13, p. 87-94, 2018. Disponível em: < http://dx.doi.org/10.1007/s12247-017-9308-7 > DOI: 10.1007/s12247-017-9308-7.
    • APA

      Almeida, T. de S. B., Lourenço, F. R., Kikuchi, I. S., Awasthi, R., Dua, K., & Pinto, T. de J. A. (2018). Evaluating the potential, applicability, and effectiveness of ozone sterilization process for medical devices. Journal of Pharmaceutical Innovation, 13, 87-94. doi:10.1007/s12247-017-9308-7
    • NLM

      Almeida T de SB, Lourenço FR, Kikuchi IS, Awasthi R, Dua K, Pinto T de JA. Evaluating the potential, applicability, and effectiveness of ozone sterilization process for medical devices [Internet]. Journal of Pharmaceutical Innovation. 2018 ; 13 87-94.Available from: http://dx.doi.org/10.1007/s12247-017-9308-7
    • Vancouver

      Almeida T de SB, Lourenço FR, Kikuchi IS, Awasthi R, Dua K, Pinto T de JA. Evaluating the potential, applicability, and effectiveness of ozone sterilization process for medical devices [Internet]. Journal of Pharmaceutical Innovation. 2018 ; 13 87-94.Available from: http://dx.doi.org/10.1007/s12247-017-9308-7

    Referências citadas na obra
    Oliveira DC, Kikuchi IS, Moreira AJ, Silva JMF, Mansano RF, Pinto TJA. Evaluation of microbiocidal activity of oxygen-containing plasma using biological monitors with different lumen calibers. Acta Farmacéutica Bonaerense. 2012;31:257–64.
    Moisan M, Barbeau J, Morreau S, Pelletier J, Tabrizian M, Yahia LH. Low-temperature sterilization using gas plasmas: a review of the experiments and an analysis of the inactivation mechanisms. Int J Pharm. 2001;226(1-2):1–21. https://doi.org/10.1016/S0378-5173(01)00752-9 .
    Boscariol MR, Moreira AJ, Mansano RD, Kikuchi IS, Pinto TJA. Sterilization by pure oxygen plasma and by oxygen–hydrogen peroxide plasma: an efficacy study. Int J Pharm. 2008;353(1-2):170–5. https://doi.org/10.1016/j.ijpharm.2007.11.059 .
    Checinska A, Fruth IA, Green TA, Growford RL, Paszczunski AJ. Sterilization of biological pathogens using supercritical fluid carbon dioxide containing water and hydrogen peroxide. J Microbiol Methods. 2011;87(1):70–5. https://doi.org/10.1016/j.mimet.2011.07.008 .
    Galante R, Ghisleni D, Paradiso P, Alves VD, Pinto TJA, Colaço R, et al. Sterilization of silicone-based hydrogels for biomedical application using ozone gas: comparison with conventional techniques. Mater Sci Eng C. 2017;78:389–97.
    Ridiquieri CF, Pinto TJA, Bou-Chacra NA, Galante R, Araújo GL, Pedrosa TN, et al. Ozone gas as a benign sterilization treatment for PLGA nanofiber scaffolds. Tissue Eng Part C Methods. 2016;22(4):338–47. https://doi.org/10.1089/ten.tec.2015.0298 .
    Moat J, Cargill J, Shone J, Mathew U. Application of a novel decontamination process using gaseous ozone. J Microbiol. 2009;55:928–33.
    Bocci V.Ozone: a new medical drug. Dordrecht. New York: Springer; 2005.
    Sousa CS, Torres LM, Azevedo MPF, Camargo TC, Graziano KU, Lacerda RA, et al. Gás ozônio na esterilização de produtos para assistência à saúde: revisão integrativa da literatura. Rev Esc EnfermUSP. 2011;45:1243–9.
    Rickloff JR. An evaluation of the sporicidal activity of ozone. Appl Environ Microbiol. 1987;53(4):683–6.
    Bocci V, Valacchi G, Corradeschi F, Fanetti G. Studies on the biological effects of ozone: 8. Effects on the total antioxidant status and on interleukin-8 production. MediatInflamm. 1993;7:313–7.
    Salmon M, Koto H, Lynch OT, Haddad EB, Lamb NJ, Quinlan GJ, et al. Proliferation of airway epithelium after ozone exposure: effect of apocynin and dexamethasone. Am J Respir Crit Care Med. 1998;157(3):970–7. https://doi.org/10.1164/ajrccm.157.3.9704067 .
    Bell M, Mcdermott A, Zeger SL, Samot JM, Dominici F. Ozone and short-term mortality in 95 US urban communities, 1987–2000. JAMA. 2004;292(19):2372–8. https://doi.org/10.1001/jama.292.19.2372 .
    Sunnen GV. Ozone in medicine: overview and future directions. J Adv Med. 1998;1(3):159–74.
    Kim JG, Yousef AE. Inactivation kinetics of foodborner spoilage and pathogenic bacteria by ozone. J Food Sci. 2000;65(3):521–8. https://doi.org/10.1111/j.1365-2621.2000.tb16040.x .
    Coronel B, Duroselle P, Behr P, Moskovtchenko JF, Freney J. In situ decontamination of medical wastes using oxidative agents: a 16 month study in a polyvalent intensive care unit. J Hosp Infect. 2002;50(3):207–12. https://doi.org/10.1053/jhin.2002.1188 .
    Sakurai M, Takahashi R, Fukunaga S, Shiomi S, Kazuma K, Shintani H. Several factors affecting ozone gas sterilization. Biocontrol Sci. 2003;18:69–76.
    Mahdoudh A, Barbeau J, Moisan M, Leduc A, Séguin J. Biocidal action of ozone–treated polystyrene surfaces on vegetative and sporulated bacteria. Appl Surf Sci. 2010;256(10):3063–72. https://doi.org/10.1016/j.apsusc.2009.11.074 .
    Luqueta GR, Santos ED, Pessoa RS, Maciel HS. Evaluation of disposable medical device packaging materials under ozone sterilization. Res Biomed Eng. 2017;33(1):58–68.
    Govindaraj S, Muthuraman MS. Systematic review on sterilization methods of implants and medical devices. Int J ChemTech Res. 2015;8:897–911.
    Shintani H, Sukuri E, Sakurai M. Determination of compounds inhibiting bacterial growth in sterilized medical devices. Chromatographia. 2003;58:193–9.
    Dufresne S, Leblond H, Chaunet M. Relationship between lumen diameter and length sterilized in the 125L ozone sterilizer. Am J Infect Control. 2008;36(4):291–7. https://doi.org/10.1016/j.ajic.2007.06.006 .
    Varga L, Szigeti J. Use of ozone in the dairy industry: a review. Int J Dairy Technol. 2016;69(2):157–68. https://doi.org/10.1111/1471-0307.12302 .
    Galante R, Rediguieri CF, Kikuchi IS, Vasquez PA, Colaco R, Serro AP, et al. About the sterilization of chitosan hydrogel nanoparticles. PLoS One. 2016;11(12):e0168862. https://doi.org/10.1371/journal.pone.0168862 .
    Murphy L. Ozone—the latest advance in sterilization of medical devices. Can Oper Room Nurs J. 2006;24:28–38.
    Pinto TJA, Kaneko TM, Pinto AF. Controle biológico de qualidade de produtos farmacêuticos, correlatos e cosméticos. Atheneu: São Paulo; 2015.
    USP. United States Pharmacopeia. Rockville: The United States Pharmacopeia Convention, 39 ed. Vol. 1; 2016. pp. 86.
    Cerf O. A review tailing of survival curves of bacterial spores. J Appl Bacteriol. 1977;42(1):1–19. https://doi.org/10.1111/j.1365-2672.1977.tb00665.x .
    Sharma M, Hudson JB. Ozone gas is an effective and practical antibacterial agent. Am J Infect Control. 2008;36(8):559–63. https://doi.org/10.1016/j.ajic.2007.10.021 .
    Yamayoshi T, Tatsumi N. Microbicidal effects of ozone solution on methicillin-sresistant Staphylococcus aureus. Drugs Exp Clin Res. 1993;19(2):59–64.
    Kowalski WJ, Banhfleth WP, Whittam TS. Bactericidal effects of high airborne ozone concentrations on Escherichia coli and Staphylococcus aureus. Ozone Sci Eng. 1998;20(3):205–21. https://doi.org/10.1080/01919519808547272 .
    Currier RP, Torraco J, Cross JB, Wagner GL, Gladden PD, Vanderberg LA. Deactivation of clumped and dirty spores of Bacillus globigii. Ozone: Sci Eng. 2001;23:285–94.
    Khadre MA, Yousef AE. Sporicidal action of ozone and hydrogen peroxide: a comparative study. Int J Food Microbiol. 2001;71(2-3):131–8. https://doi.org/10.1016/S0168-1605(01)00561-X .
    BuranovSN, KarelinVI, SelemirVD, VorobievaON, TsarevaAS, ShkarinVV. 2005. Sterilizing effect of ozone on live spores of anthrax bacillusPulsed Power Conference, IEEE. doi: https://doi.org/10.1109/PPC.2005.300669 available from: http://ieeexplore.ieee.org/document/4084496/?part=1 (assessed on 16.11.2016).
    Tseng C, Li C. Inactivation of surfaces viruses by gaseous ozone. J Environ Health. 2008;70(10):56–62.
    Karpuz M, Ozer AY. Syringes as medical devices. FABAD J Pharm Sci. 2016;41:27–31. ISSN 1300–4182