Detection of architectural distortion in digitized screen-film mammograms using texture descriptors (2016)
- Authors:
- USP affiliated authors: GONZAGA, ADILSON - EESC ; VIEIRA, MARCELO ANDRADE DA COSTA - EESC
- Unidade: EESC
- Subjects: DIGITALIZAÇÃO; MAMOGRAFIA; ENGENHARIA ELÉTRICA
- Keywords: ARCHITECTURAL DISTORTION
- Language: Português
- Imprenta:
- Publisher: UCDB
- Publisher place: Campo Grande, MS
- Date published: 2016
- Source:
- Título: Proceedings
- ISSN: 2175-6120
- Conference titles: Workshop de Visão Computacional - WVC
-
ABNT
OLIVEIRA, Helder Cesar Rodrigues de et al. Detection of architectural distortion in digitized screen-film mammograms using texture descriptors. 2016, Anais.. Campo Grande, MS: UCDB, 2016. . Acesso em: 28 fev. 2026. -
APA
Oliveira, H. C. R. de, Moraes, D. R., Gonzaga, A., & Vieira, M. A. da C. (2016). Detection of architectural distortion in digitized screen-film mammograms using texture descriptors. In Proceedings. Campo Grande, MS: UCDB. -
NLM
Oliveira HCR de, Moraes DR, Gonzaga A, Vieira MA da C. Detection of architectural distortion in digitized screen-film mammograms using texture descriptors. Proceedings. 2016 ;[citado 2026 fev. 28 ] -
Vancouver
Oliveira HCR de, Moraes DR, Gonzaga A, Vieira MA da C. Detection of architectural distortion in digitized screen-film mammograms using texture descriptors. Proceedings. 2016 ;[citado 2026 fev. 28 ] - A new texture descriptor based on local micro-pattern for detection of architectural distortion in mammographic images
- Reduction of false-positives in a CAD scheme for automated detection of architectural distortion in digital mammography
- A novel fusion-based texture descriptor to improve the detection of architectural distortion in digital mammography
- Method of inserting Poisson noise in digital mammography images to simulate radiation dose reduction
- Poisson Wiener filtering with non-local weighted parameter estimation using stochastic distances
- Mesa eletrônica de alinhamento para localização automática do feixe central de raios-X em equipamentos radiográficos
- Mapeamento, classificação e dimensionamento de áreas geográficas por sensoriamento remoto utilizando processamento de imagens
- Guassian-Poisson noise estimation from individual mammography images
- Sistema computadorizado para alinhamento automático e aferição do ponto focal de equipamentos mamográficos utilizando sensor CCD odontológico
- Uso do algoritmo de médias não-locais para filtragem do ruído de mamogramas adquiridos com dose reduzida
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas