Stress distribution around dental implants with different insertion depths: a photoelastic study (2014)
- Authors:
- USP affiliated authors: STEGUN, ROBERTO CHAIB - FO ; COSTA, BRUNO - FO ; MORI, MATSUYOSHI - FO ; LAGANA, DALVA CRUZ - FO
- Unidade: FO
- Assunto: IMPLANTES DENTÁRIOS
- Language: Português
- Abstract: The progressive bone loss at the neck of the implant is a clinical concern since it affects the maintenance of dental esthetics. The stress concentration, the connection type and the microgap appear to be factors that cause alterations at the marginal bone level. The present study evaluated the influence of insertion depth, prosthetic connection and type of loading on the stress distribution around dental implants, using photoelastic methodology. Three blocks of photoelastic resin for each type of implant connection (external hexagon, external hexagon flattened, internal hexagon and Morse taper) were built. Each block differed in the position of the implant platform in relative to the upper margin of the block: I (2mm below), II (at the same level) and III (2mm above). A 100N force was applied to both a straight and tilted abutments. A multiple linear regression showed the relation between the stress distribution and the insertion depth. For all the implant types, both with straight and tilted abutments, Group I presented the lowest stress concentration around the fixture when compared to group II and III(p<0,05)
- Imprenta:
- Source:
- Título: Brazilian Oral Resarch
- ISSN: 1806-8324
- Volume/Número/Paginação/Ano: v.28, supl. 1, p. 35, res. HA021, 2014
- Conference titles: Reunião Anual SBPqO
-
ABNT
ZANARDI, P. R et al. Stress distribution around dental implants with different insertion depths: a photoelastic study. Brazilian Oral Resarch. São Paulo: Faculdade de Odontologia, Universidade de São Paulo. . Acesso em: 31 out. 2024. , 2014 -
APA
Zanardi, P. R., Sesma, N., Stegun, R. C., Costa, B., Mori, M., Mukai, M. K., & Laganá, D. C. (2014). Stress distribution around dental implants with different insertion depths: a photoelastic study. Brazilian Oral Resarch. São Paulo: Faculdade de Odontologia, Universidade de São Paulo. -
NLM
Zanardi PR, Sesma N, Stegun RC, Costa B, Mori M, Mukai MK, Laganá DC. Stress distribution around dental implants with different insertion depths: a photoelastic study. Brazilian Oral Resarch. 2014 ;28 35.[citado 2024 out. 31 ] -
Vancouver
Zanardi PR, Sesma N, Stegun RC, Costa B, Mori M, Mukai MK, Laganá DC. Stress distribution around dental implants with different insertion depths: a photoelastic study. Brazilian Oral Resarch. 2014 ;28 35.[citado 2024 out. 31 ] - SEM evaluation of the fit of interchanged prosthetic components
- Connecting accuracy of interchanged prosthetic abutments to different dental implants using scanning electron microscopy
- Observação da ausência dentária associando-a ao grau de instrução e ao nível sócioeconômico da população estudada
- Development of pneumatic mechanical cycling machines for rpd tests
- Avaliação da força de tração de sela modificada para prótese
- Próteses flexíveis e outros meios de retenção em prótese removível
- Avaliação da relação entre a linha bipupilar e a comissura labial
- Prótese removível: método 8+1
- Avaliação da atividade microbiana sobre bases protéticas convencionais e termoplásticas
- Desenvolvimento de máquina de ciclagem mecânica pneumática para ensaios de PPR
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas