The Effect of the distance between transformer and MV arresters on the surges transferred to the LV side (2012)
- Authors:
- USP affiliated authors: PIANTINI, ALEXANDRE - IEE ; CARVALHO, THAIS OHARA DE - IEE ; OBASE, PAULO FUTOSHI - IEE ; JANISZEWSKI, JORGE MIECZYSLAW - EP
- Unidades: IEE; EP
- Subjects: SISTEMAS ELÉTRICOS DE POTÊNCIA; SISTEMAS ELÉTRICOS DE POTÊNCIA (PROTEÇÃO)
- Language: Inglês
- Imprenta:
- Publisher: IEEE
- Publisher place: Piscataway
- Date published: 2012
- Source:
- Título: Proceedings. ICHVE 2012
- Conference titles: International Conference on High Voltage Engineering and Application
-
ABNT
PIANTINI, Alexandre et al. The Effect of the distance between transformer and MV arresters on the surges transferred to the LV side. 2012, Anais.. Piscataway: IEEE, 2012. . Acesso em: 29 dez. 2025. -
APA
Piantini, A., Carvalho, T. O. de, Obase, P. F., Janiszewski, J. M., Santos, G. J. G., Fagundes, D. R., et al. (2012). The Effect of the distance between transformer and MV arresters on the surges transferred to the LV side. In Proceedings. ICHVE 2012. Piscataway: IEEE. -
NLM
Piantini A, Carvalho TO de, Obase PF, Janiszewski JM, Santos GJG, Fagundes DR, Uchoa JIL, Kunz EN. The Effect of the distance between transformer and MV arresters on the surges transferred to the LV side. Proceedings. ICHVE 2012. 2012 ;[citado 2025 dez. 29 ] -
Vancouver
Piantini A, Carvalho TO de, Obase PF, Janiszewski JM, Santos GJG, Fagundes DR, Uchoa JIL, Kunz EN. The Effect of the distance between transformer and MV arresters on the surges transferred to the LV side. Proceedings. ICHVE 2012. 2012 ;[citado 2025 dez. 29 ] - The influence of surge arrester location on over-voltages caused by direct lightning strikes to MV lines
- Lightning overvoltages caused by direct strikes to distribution lines
- Analysis of lightning-caused distribution transformer failures
- Overvoltages on urban LV distribution lines caused by direct strokes to primary lines
- Lightning surges transferred to the secondary of distribution transformers due to direct strikes on MV lines, considering different LV line configurations
- Analysis of the effect of lightning on the energized shield wire line technology
- Surtos atmosféricos transferidos à rede secundária via transformadores
- Estudo do efeito de pára-raios nas sobretensões induzidas por descargas atmosféricas em linha de média tensão e desenvolvimento de metodologia para simulação computacional de sistemas de aterramento submetidos a correntes impulsivas:: Relatório Quadrimestral
- Modelo reduzido de linha aerea para estudo de sobretensoes induzidas
- Simulação de pára-raios para estudo, em escala reduzida, de sobretensões causadas por descargas atmosféricas indiretas
How to cite