Accuracy of root length determination using tri auto ZX and proTaper instruments: an in vitro study (2006)
- Authors:
- Autor USP: BRAMANTE, CLOVIS MONTEIRO - FOB
- Unidade: FOB
- Subjects: COMPROMETIMENTO; CANAL RADICULAR
- Language: Inglês
- Abstract: The accuracy of the electronic apex locator feature of Tri Auto ZX was assessed. Twenty distobuccal roots were selected and, after endodontic access, placed in plastic cylinders filled with 2% agar until completely covered. The roots were divided in two groups according to the calibration of the automatic apical reverse mechanism of Tri Auto ZX, at 1 and 2 mm from the apical foramen. Preparation was performed with ProTaper instruments connected to the device. Afterwards, the last file used was introduced into the canal and fixed in place with acrylic resin. The roots were removed from the agar and ground until exposure of the file. The distances between file tip and apical foramen were submitted to statistical analysis. The distances reached were actually shorter than the preset distances in every case, however, they were considered clinically acceptable. Setting the reverse mechanism at 1 mm was more reliable than at 2 mm
- Imprenta:
- Source:
- Título: Journal of Endodontics
- ISSN: 0099-2399
- Volume/Número/Paginação/Ano: v. 32, n. 2, p. 142-144, Feb. 2006
-
ABNT
CARNEIRO, Everdan et al. Accuracy of root length determination using tri auto ZX and proTaper instruments: an in vitro study. Journal of Endodontics, v. 32, n. 2, p. 142-144, 2006Tradução . . Disponível em: http://www.sciencedirect.com/science/journal/00992399. Acesso em: 12 mar. 2026. -
APA
Carneiro, E., Bramante, C. M., Picoli, F., Letra, A., Silva Neto, U. X. da, & Menezes, R. (2006). Accuracy of root length determination using tri auto ZX and proTaper instruments: an in vitro study. Journal of Endodontics, 32( 2), 142-144. Recuperado de http://www.sciencedirect.com/science/journal/00992399 -
NLM
Carneiro E, Bramante CM, Picoli F, Letra A, Silva Neto UX da, Menezes R. Accuracy of root length determination using tri auto ZX and proTaper instruments: an in vitro study [Internet]. Journal of Endodontics. 2006 ; 32( 2): 142-144.[citado 2026 mar. 12 ] Available from: http://www.sciencedirect.com/science/journal/00992399 -
Vancouver
Carneiro E, Bramante CM, Picoli F, Letra A, Silva Neto UX da, Menezes R. Accuracy of root length determination using tri auto ZX and proTaper instruments: an in vitro study [Internet]. Journal of Endodontics. 2006 ; 32( 2): 142-144.[citado 2026 mar. 12 ] Available from: http://www.sciencedirect.com/science/journal/00992399 - Receptor activator NFkB-ligand and osteoprotegerin protein expression in human periapical cysts and granulomas
- Retratamento com utilização do microscópio
- Correções cirúrgicas das complicações e acidentes da endodontia
- A Endodontia é o ramo da Odontologia que cuida do diagnóstico... [Apresentação]
- Correlacao entre os espacadores limas e cones acessorios
- Localizadores foraminais eletrônicos (terceira geração)
- Sistema Protaper: características, técnica y presentación de un caso clínico
- Desinfecção intra-tubular pelas pastas de hidróxido de cálcio e tri-antibiótica
- Multidisciplinary treatment of a patient with geminated maxillary central incisors
- Análisis comparativo de la preparación de conductos radiculares curvos empleando instrumentos de níquel titanio con o sin EDTA
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas