Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system (2000)
- Authors:
- USP affiliated authors: REIS, BOAVENTURA FREIRE DOS - CENA ; ZAGATTO, ELIAS AYRES GUIDETTI - CENA
- Unidade: CENA
- DOI: 10.1039/a907917c
- Subjects: QUÍMICA ANALÍTICA; QUÍMICA ANALÍTICA INSTRUMENTAL
- Language: Inglês
- Abstract: An automatic flow titrator based on a multicommutated unsegmented flow system was used to perform precipitation titrations with potentiometric detection. The titration approach is based on sequential introduction of increasing titrant volumes into a mixing chamber. The system allows the attainment of complete curves, the titration end point being determined by the Gran method, as is usually employed in batch potentiometric titrations. The theoretical model for the analytical process is presented and discussed and the determination of titrand concentration is performed without any prior calibration. The automatic flow titrator developed was applied to chloride determination in bottled natural waters and the results obtained were reproducible (RSD 3.2 and 3.8% for repeatability and reproducibility, respectively) and in good agreement with those given by the reference procedure (relative deviation within the range from -4.6 to 4.8%)
- Imprenta:
- Source:
- Título: The Analyst
- Volume/Número/Paginação/Ano: v. 125, p. 333-340, 2000
- Este artigo NÃO possui versão em acesso aberto
-
Status: Nenhuma versão em acesso aberto identificada -
ABNT
ALMEIDA, C M N V et al. Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system. The Analyst, v. 125, p. 333-340, 2000Tradução . . Disponível em: https://doi.org/10.1039/a907917c. Acesso em: 11 mar. 2026. -
APA
Almeida, C. M. N. V., Araujo, M. C. U., Lapa, R. A. S., Lima, J. L. F. C., Reis, B. F. dos, & Zagatto, E. A. G. (2000). Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system. The Analyst, 125, 333-340. doi:10.1039/a907917c -
NLM
Almeida CMNV, Araujo MCU, Lapa RAS, Lima JLFC, Reis BF dos, Zagatto EAG. Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system [Internet]. The Analyst. 2000 ; 125 333-340.[citado 2026 mar. 11 ] Available from: https://doi.org/10.1039/a907917c -
Vancouver
Almeida CMNV, Araujo MCU, Lapa RAS, Lima JLFC, Reis BF dos, Zagatto EAG. Precipitation titrations using an automatic titrator based on a multicommutated unsegmented flow system [Internet]. The Analyst. 2000 ; 125 333-340.[citado 2026 mar. 11 ] Available from: https://doi.org/10.1039/a907917c - Tandem flow analysis applied to food and agricultural samples
- Detecting and circumventing sources of inaccuracy in flow analysis
- Potentiometric flow injection determination of glycerol in distilled spirits
- Sistema FIA com splitting controlado por valvula solenoide: determinacao simultanea de cobre e zinco em plantas
- Sequential injection catalytic determination of iodide in iodised table salt
- Improved monosegmented continuous glow system for sample introduction in flame atomic spectrometry
- Trial measurements in flow analysis
- The commutation concept associated to the development of flow analysis
- Sistema em fluxo multi-tarefa: Determinação potenciométrica de vitamina 'B IND. 6' em formulações farmacêuticas
- Detecting and circumventing sources of inaccuracy in flow analysis
Informações sobre a disponibilidade de versões do artigo em acesso aberto coletadas automaticamente via oaDOI API (Unpaywall).
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
