Linear relationship between potential and concentration in flow potentiometry (2000)
- Authors:
- Autor USP: ZAGATTO, ELIAS AYRES GUIDETTI - CENA
- Unidade: CENA
- DOI: 10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s
- Subjects: QUÍMICA ANALÍTICA; QUÍMICA ANALÍTICA INSTRUMENTAL
- Language: Inglês
- Abstract: In potentiometric-flow systems, linear-potential responses for logarithmic concentrations can be attained for first-(or pseudo-first-) order reactions in which the monitored chemical species react with the analyte during a fixed time interval. To demonstrate this property, the determination of glycerol based on its oxidation by periodate and potentiometric monitoring of the remaining periodate was selected. Influence of reagent concentration and timing on the linearity of the analytical curve were investigated. A mathematical treatment was derived, and potentialities/limitations of the approach were outlined. The system was applied to analysis of soap and lixivia samples. The analytical curve within 200 and 2000 mg L-1 (r=0,99975; n=5) was described as E=8.166 + 0.0478 (glycerol). The sample throughput was 100 h(-1), and a measurement repeatability within 0.5 mV was always observed. By applying a t-test, there was no statistical difference between the results obtained by the proposed procedure and by iodimetric titration at the 95% confidence level
- Imprenta:
- Source:
- Título: Laboratory Robotics and Automation
- Volume/Número/Paginação/Ano: v. 12, n. 1, p. 41-45, 2000
- Este periódico é de assinatura
- Este artigo NÃO é de acesso aberto
- Cor do Acesso Aberto: closed
-
ABNT
NETO, J A G e ZAGATTO, Elias Ayres Guidetti. Linear relationship between potential and concentration in flow potentiometry. Laboratory Robotics and Automation, v. 12, n. 1, p. 41-45, 2000Tradução . . Disponível em: https://doi.org/10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s. Acesso em: 27 dez. 2025. -
APA
Neto, J. A. G., & Zagatto, E. A. G. (2000). Linear relationship between potential and concentration in flow potentiometry. Laboratory Robotics and Automation, 12( 1), 41-45. doi:10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s -
NLM
Neto JAG, Zagatto EAG. Linear relationship between potential and concentration in flow potentiometry [Internet]. Laboratory Robotics and Automation. 2000 ; 12( 1): 41-45.[citado 2025 dez. 27 ] Available from: https://doi.org/10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s -
Vancouver
Neto JAG, Zagatto EAG. Linear relationship between potential and concentration in flow potentiometry [Internet]. Laboratory Robotics and Automation. 2000 ; 12( 1): 41-45.[citado 2025 dez. 27 ] Available from: https://doi.org/10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s - Exploitation of a single interface flow system for on-line aqueous biphasic extraction: a Brazilian triumph. [Entrevista a Adimilson Cerqueira]
- Determinação espectrofotométrica simultânea de cobre e níquel explorando cinética diferencial e quimiometria
- Mini-sondas em sistemas de análise em fluxo:: uma estratégia pouco invasiva
- Multipumping flow systems: an alternative approach to sample handling in spectroscopy measurements
- Determinação indireta de N-total em plantas por espectrometria de absorção atômica com chama empregando uma mini-coluna de AgCl(s)
- Prior assay as an approach to flow titrations: Spectrophotometric determination of iron in alloys and ores
- A flow system for video demonstrations:: comparative evaluation of the stability of some cuprate(II) complexes
- Determinação de cobalto em tecido animal utilizando sistema FIA e detecção quimiluminescente
- Spectrophotometric flow-injection determination of zinc in plant digests based on a spot test
- Multi-pumping flow systems: the potential of simplicity
Informações sobre o DOI: 10.1002/(sici)1098-2728(2000)12:1%3C41::aid-lra8%3E3.3.co;2-s (Fonte: oaDOI API)
How to cite
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas