Prospective clinical evaluation of dental implants with sand-blasted, large-grit, acid-etched surfaces loaded 6 weeks after surgery (2004)
- Autores:
- Autor USP: TORTAMANO NETO, PEDRO - FO
- Unidade: FO
- Assuntos: IMPLANTE DENTÁRIO ENDOÓSSEO; MOBILIDADE DENTÁRIA
- Idioma: Inglês
- Resumo: Twenty implants with sand-blasted, large-grit, acid-etched (SLA) surfaces (ITI Dental System) were followed up for a period of 12 months, during which the following clinical criteria were evaluated: (a) absence of persistent clinical symptoms (pain, strange sensations, or paresthesia) after the placement of implants; (b) absence of recurring peri-implant inflammation or suppuration; (c) absence of increasing mobility, tested with Periotest; and (d) absence of bone loss or radiolucency around the implants. After 12 months of follow-up, all the loaded implants, after 6 weeks of placement, were approved under all the aforementioned criteria. During the analysis of the increasing mobility, tested with Periotest, and grouping these implants according to the site of implantation (mandible or maxilla), it was possible to observe that the implants presented the same increasing mobility
- Imprenta:
- Local: Carol Stream
- Data de publicação: 2004
- Fonte:
- Título do periódico: Quintessence International
- ISSN: 0033-6572
- Volume/Número/Paginação/Ano: v. 35, n. 9, p. 717-722, October 2004
-
ABNT
TORTAMANO NETO, Pedro e CAMARGO, Luiz Otavio Alves. Prospective clinical evaluation of dental implants with sand-blasted, large-grit, acid-etched surfaces loaded 6 weeks after surgery. Quintessence International, v. 35, n. 9, p. 717-722, 2004Tradução . . Acesso em: 28 mar. 2024. -
APA
Tortamano Neto, P., & Camargo, L. O. A. (2004). Prospective clinical evaluation of dental implants with sand-blasted, large-grit, acid-etched surfaces loaded 6 weeks after surgery. Quintessence International, 35( 9), 717-722. -
NLM
Tortamano Neto P, Camargo LOA. Prospective clinical evaluation of dental implants with sand-blasted, large-grit, acid-etched surfaces loaded 6 weeks after surgery. Quintessence International. 2004 ; 35( 9): 717-722.[citado 2024 mar. 28 ] -
Vancouver
Tortamano Neto P, Camargo LOA. Prospective clinical evaluation of dental implants with sand-blasted, large-grit, acid-etched surfaces loaded 6 weeks after surgery. Quintessence International. 2004 ; 35( 9): 717-722.[citado 2024 mar. 28 ] - A implantação teve o seu grande avanço com a técnica... [Apresentação]
- Immediate implant placement and restoration in the esthetic zone: a prospective study with 18 months of follow-up
- Moldagem em implantodontia
- Estudo das tensoes transmitidas a mandibula por uma protese totalmente implanto-suportada, variando-se o padrao oclusal, atraves do metodo dos elementos finitos
- Estudo da distribuicao das tensoes transmitidas a mandibula por um implante oteointegrado, variando-se a espessura do osso cortical e a direcao da carga aplicada por meio do metodo de elementos finitos
- Conduta de planejamento em setores estéticos associados à carga imediata: descrição de caso clínico
- Novas superfícies para a osseointegração otimizando a carga imediata e a carga precoce. [Depoimento]
- Avaliação da precisão de quatro técnicas de moldagem de transferência para implantes osseointegrados
- Loading protocols in implant dentistrry: edentulous patients
- Accuracy of Four Transfer Impression Techniques for Dental Implants: A Scanning Electron Microscopic Analysis
Como citar
A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas