Filtros : "Indexado na Web of Science" "Microchimica Acta" Limpar

Filtros



Limitar por data


  • Fonte: Microchimica Acta. Unidade: IQSC

    Assuntos: DOENÇA DE PARKINSON, ELETROQUÍMICA

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ORZARI, Luiz Otávio et al. Lab‑made disposable screen‑printed electrochemical sensors and immunosensors modifed with Pd nanoparticles for Parkinson’s disease diagnostics. Microchimica Acta, v. 191, p. 76, 2024Tradução . . Disponível em: https://doi.org/10.1007/s00604-023-06158-3. Acesso em: 04 nov. 2024.
    • APA

      Orzari, L. O., Silva, L. R. G. e, Freitas, R. C. de, Brazaca, L. C., & Janegitz, B. C. (2024). Lab‑made disposable screen‑printed electrochemical sensors and immunosensors modifed with Pd nanoparticles for Parkinson’s disease diagnostics. Microchimica Acta, 191, 76. doi:10.1007/s00604-023-06158-3
    • NLM

      Orzari LO, Silva LRG e, Freitas RC de, Brazaca LC, Janegitz BC. Lab‑made disposable screen‑printed electrochemical sensors and immunosensors modifed with Pd nanoparticles for Parkinson’s disease diagnostics [Internet]. Microchimica Acta. 2024 ;191 76.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-023-06158-3
    • Vancouver

      Orzari LO, Silva LRG e, Freitas RC de, Brazaca LC, Janegitz BC. Lab‑made disposable screen‑printed electrochemical sensors and immunosensors modifed with Pd nanoparticles for Parkinson’s disease diagnostics [Internet]. Microchimica Acta. 2024 ;191 76.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-023-06158-3
  • Fonte: Microchimica Acta. Unidade: IQSC

    Assuntos: VOLTAMETRIA, AMPEROMETRIA

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      BLASQUES, Rodrigo Vieira et al. Reusable graphite‑based electrochemical sensors for L‑dopa and dopamine detection. Microchimica Acta, p. 191-197, 2024Tradução . . Disponível em: https://doi.org/10.1007/s00604-024-06271-x. Acesso em: 04 nov. 2024.
    • APA

      Blasques, R. V., Stefano, J. S., Silva, V. A. O. P. da, Brazaca, L. C., & Janegitz, B. C. (2024). Reusable graphite‑based electrochemical sensors for L‑dopa and dopamine detection. Microchimica Acta, 191-197. doi:10.1007/s00604-024-06271-x
    • NLM

      Blasques RV, Stefano JS, Silva VAOP da, Brazaca LC, Janegitz BC. Reusable graphite‑based electrochemical sensors for L‑dopa and dopamine detection [Internet]. Microchimica Acta. 2024 ;191-197.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06271-x
    • Vancouver

      Blasques RV, Stefano JS, Silva VAOP da, Brazaca LC, Janegitz BC. Reusable graphite‑based electrochemical sensors for L‑dopa and dopamine detection [Internet]. Microchimica Acta. 2024 ;191-197.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06271-x
  • Fonte: Microchimica Acta. Unidade: IQSC

    Assuntos: FILMES, AMIDO, ÓPTICA ELETRÔNICA, SENSOR, DETERIORAÇÃO DE ALIMENTOS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ROVEDA JUNIOR, Antonio Carlos et al. Transparent, flexible, and eco-friendly starch-based films for reversible optoelectronic noses for food spoilage monitoring in smart packaging. Microchimica Acta, v. 191, 2024Tradução . . Disponível em: https://doi.org/10.1007/s00604-024-06426-w. Acesso em: 04 nov. 2024.
    • APA

      Roveda Junior, A. C., Dias, B. C., Passini, L. do N., Manzani, D., & Petruci, J. F. da S. (2024). Transparent, flexible, and eco-friendly starch-based films for reversible optoelectronic noses for food spoilage monitoring in smart packaging. Microchimica Acta, 191. doi:10.1007/s00604-024-06426-w
    • NLM

      Roveda Junior AC, Dias BC, Passini L do N, Manzani D, Petruci JF da S. Transparent, flexible, and eco-friendly starch-based films for reversible optoelectronic noses for food spoilage monitoring in smart packaging [Internet]. Microchimica Acta. 2024 ;191[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06426-w
    • Vancouver

      Roveda Junior AC, Dias BC, Passini L do N, Manzani D, Petruci JF da S. Transparent, flexible, and eco-friendly starch-based films for reversible optoelectronic noses for food spoilage monitoring in smart packaging [Internet]. Microchimica Acta. 2024 ;191[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06426-w
  • Fonte: Microchimica Acta. Unidade: IQSC

    Assuntos: DOENÇA DE PARKINSON, OURO, ELETRODO

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ORZARI, Luiz Otávio e BRAZACA, Lais Canniatti e JANEGITZ, Bruno Campos. Parkinson biomarker determination with an Au microfower–enhanced electrochemical immunosensor using non‑Faradaic capacitance measurements. Microchimica Acta, p. 191-663, 2024Tradução . . Disponível em: https://doi.org/10.1007/s00604-024-06747-w. Acesso em: 04 nov. 2024.
    • APA

      Orzari, L. O., Brazaca, L. C., & Janegitz, B. C. (2024). Parkinson biomarker determination with an Au microfower–enhanced electrochemical immunosensor using non‑Faradaic capacitance measurements. Microchimica Acta, 191-663. doi:10.1007/s00604-024-06747-w
    • NLM

      Orzari LO, Brazaca LC, Janegitz BC. Parkinson biomarker determination with an Au microfower–enhanced electrochemical immunosensor using non‑Faradaic capacitance measurements [Internet]. Microchimica Acta. 2024 ;191-663.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06747-w
    • Vancouver

      Orzari LO, Brazaca LC, Janegitz BC. Parkinson biomarker determination with an Au microfower–enhanced electrochemical immunosensor using non‑Faradaic capacitance measurements [Internet]. Microchimica Acta. 2024 ;191-663.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-024-06747-w
  • Fonte: Microchimica Acta. Unidades: IQSC, IQ

    Assuntos: DOENÇA DE ALZHEIMER, ELETROQUÍMICA

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      NEGAHDARY, Masoud et al. Design of an electrochemical aptasensor in the presence of an array of gold nanostructure and a GO‑MWCNTs nanocomposite: application in diagnosis of Alzheimer’s disease. Microchimica Acta, v. 190, p. 1-13 art. 409, 2023Tradução . . Disponível em: https://doi.org/10.1007/s00604-023-05995-6. Acesso em: 04 nov. 2024.
    • APA

      Negahdary, M., Buoro, R. M., Bacil, R. P., Santos, B. G., & Angnes, L. (2023). Design of an electrochemical aptasensor in the presence of an array of gold nanostructure and a GO‑MWCNTs nanocomposite: application in diagnosis of Alzheimer’s disease. Microchimica Acta, 190, 1-13 art. 409. doi:10.1007/s00604-023-05995-6
    • NLM

      Negahdary M, Buoro RM, Bacil RP, Santos BG, Angnes L. Design of an electrochemical aptasensor in the presence of an array of gold nanostructure and a GO‑MWCNTs nanocomposite: application in diagnosis of Alzheimer’s disease [Internet]. Microchimica Acta. 2023 ;190 1-13 art. 409.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-023-05995-6
    • Vancouver

      Negahdary M, Buoro RM, Bacil RP, Santos BG, Angnes L. Design of an electrochemical aptasensor in the presence of an array of gold nanostructure and a GO‑MWCNTs nanocomposite: application in diagnosis of Alzheimer’s disease [Internet]. Microchimica Acta. 2023 ;190 1-13 art. 409.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-023-05995-6
  • Fonte: Microchimica Acta. Unidades: IFSC, IQSC

    Assuntos: ELETROQUÍMICA, ANTÍGENOS, NEOPLASIAS MAMÁRIAS, SENSORES BIOMÉDICOS, CARBOIDRATOS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      MARTINS, Thiago Serafim et al. A sandwich-type electrochemical immunosensor based on Au-rGO composite for CA15-3 tumor marker detection. Microchimica Acta, v. 189, n. Ja 2022, p. 38-1-38-7, 2022Tradução . . Disponível em: https://doi.org/10.1007/s00604-021-05145-w. Acesso em: 04 nov. 2024.
    • APA

      Martins, T. S., Bott Neto, J. L., Oliveira Junior, O. N. de, & Machado, S. A. S. (2022). A sandwich-type electrochemical immunosensor based on Au-rGO composite for CA15-3 tumor marker detection. Microchimica Acta, 189( Ja 2022), 38-1-38-7. doi:10.1007/s00604-021-05145-w
    • NLM

      Martins TS, Bott Neto JL, Oliveira Junior ON de, Machado SAS. A sandwich-type electrochemical immunosensor based on Au-rGO composite for CA15-3 tumor marker detection [Internet]. Microchimica Acta. 2022 ; 189( Ja 2022): 38-1-38-7.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-021-05145-w
    • Vancouver

      Martins TS, Bott Neto JL, Oliveira Junior ON de, Machado SAS. A sandwich-type electrochemical immunosensor based on Au-rGO composite for CA15-3 tumor marker detection [Internet]. Microchimica Acta. 2022 ; 189( Ja 2022): 38-1-38-7.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-021-05145-w
  • Fonte: Microchimica Acta. Unidades: IQSC, IFSC

    Assuntos: ELETROQUÍMICA, POLUIÇÃO AMBIENTAL, SENSOR, ELETRODO, VOLTAMETRIA

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      GOMES, Nathalia Oezau et al. Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples. Microchimica Acta, v. 188, n. 10, p. 359-1-359-10, 2021Tradução . . Disponível em: https://doi.org/10.1007/s00604-021-05024-4. Acesso em: 04 nov. 2024.
    • APA

      Gomes, N. O., Mendonça, C. D., Machado, S. A. S., Oliveira Junior, O. N. de, & Raymundo-Pereira, P. A. (2021). Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples. Microchimica Acta, 188( 10), 359-1-359-10. doi:10.1007/s00604-021-05024-4
    • NLM

      Gomes NO, Mendonça CD, Machado SAS, Oliveira Junior ON de, Raymundo-Pereira PA. Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples [Internet]. Microchimica Acta. 2021 ; 188( 10): 359-1-359-10.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-021-05024-4
    • Vancouver

      Gomes NO, Mendonça CD, Machado SAS, Oliveira Junior ON de, Raymundo-Pereira PA. Flexible and integrated dual carbon sensor for multiplexed detection of nonylphenol and paroxetine in tap water samples [Internet]. Microchimica Acta. 2021 ; 188( 10): 359-1-359-10.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-021-05024-4
  • Fonte: Microchimica Acta. Unidade: IFSC

    Assuntos: DIAGNÓSTICO CLÍNICO, BIOMARCADORES, NEOPLASIAS, NEOPLASIAS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      ALMEIDA, Sthéfane Valle de et al. Cancer immunosensor based on apo and holo transferrin binding. Microchimica Acta, v. 187, n. 8, p. 438-1-438-9, 2020Tradução . . Disponível em: https://doi.org/10.1007/s00604-020-04420-6. Acesso em: 04 nov. 2024.
    • APA

      Almeida, S. V. de, Cancino-Bernardi, J., Andrade, J. K. de, Felsner, M. L., Zucolotto, V., & Galli, A. (2020). Cancer immunosensor based on apo and holo transferrin binding. Microchimica Acta, 187( 8), 438-1-438-9. doi:10.1007/s00604-020-04420-6
    • NLM

      Almeida SV de, Cancino-Bernardi J, Andrade JK de, Felsner ML, Zucolotto V, Galli A. Cancer immunosensor based on apo and holo transferrin binding [Internet]. Microchimica Acta. 2020 ; 187( 8): 438-1-438-9.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04420-6
    • Vancouver

      Almeida SV de, Cancino-Bernardi J, Andrade JK de, Felsner ML, Zucolotto V, Galli A. Cancer immunosensor based on apo and holo transferrin binding [Internet]. Microchimica Acta. 2020 ; 187( 8): 438-1-438-9.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04420-6
  • Fonte: Microchimica Acta. Unidade: IFSC

    Assuntos: POLÍMEROS (MATERIAIS), SENSOR, FILMES FINOS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      IBÁÑEZ-REDÍN, Glenda Gisela et al. Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9. Microchimica Acta, v. 187, n. 7, p. 417-1-417-11, 2020Tradução . . Disponível em: https://doi.org/10.1007/s00604-020-04404-6. Acesso em: 04 nov. 2024.
    • APA

      Ibáñez-Redín, G. G., Vásques, E. M. M., Furuta, R. H. M., Masso, D. W., Nascimento, G. F. do, Melendez, M. E., et al. (2020). Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9. Microchimica Acta, 187( 7), 417-1-417-11. doi:10.1007/s00604-020-04404-6
    • NLM

      Ibáñez-Redín GG, Vásques EMM, Furuta RHM, Masso DW, Nascimento GF do, Melendez ME, Carvalho AL, Reis RM, Oliveira Junior ON de, Gonçalves D. Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9 [Internet]. Microchimica Acta. 2020 ; 187( 7): 417-1-417-11.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04404-6
    • Vancouver

      Ibáñez-Redín GG, Vásques EMM, Furuta RHM, Masso DW, Nascimento GF do, Melendez ME, Carvalho AL, Reis RM, Oliveira Junior ON de, Gonçalves D. Screen-printed electrodes modified with carbon black and polyelectrolyte films for determination of cancer marker carbohydrate antigen 19-9 [Internet]. Microchimica Acta. 2020 ; 187( 7): 417-1-417-11.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04404-6
  • Fonte: Microchimica Acta. Unidade: IFSC

    Assuntos: SENSORES BIOMÉDICOS, BIOMARCADORES, NANOPARTÍCULAS, FILMES FINOS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      IBÁÑEZ-REDÍN, Glenda Gisela et al. Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe2O4 nanoparticles. Microchimica Acta, v. No 2020, n. 11, p. 619-1-619-10, 2020Tradução . . Disponível em: https://doi.org/10.1007/s00604-020-04594-z. Acesso em: 04 nov. 2024.
    • APA

      Ibáñez-Redín, G. G., Joshi, N., Nascimento, G. F. do, Masso, D. W., Melendez, M. E., Carvalho, A. L., et al. (2020). Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe2O4 nanoparticles. Microchimica Acta, No 2020( 11), 619-1-619-10. doi:10.1007/s00604-020-04594-z
    • NLM

      Ibáñez-Redín GG, Joshi N, Nascimento GF do, Masso DW, Melendez ME, Carvalho AL, Reis RM, Gonçalves D, Oliveira Junior ON de. Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe2O4 nanoparticles [Internet]. Microchimica Acta. 2020 ; No 2020( 11): 619-1-619-10.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04594-z
    • Vancouver

      Ibáñez-Redín GG, Joshi N, Nascimento GF do, Masso DW, Melendez ME, Carvalho AL, Reis RM, Gonçalves D, Oliveira Junior ON de. Determination of p53 biomarker using an electrochemical immunoassay based on layer-by-layer films with NiFe2O4 nanoparticles [Internet]. Microchimica Acta. 2020 ; No 2020( 11): 619-1-619-10.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-020-04594-z
  • Fonte: Microchimica Acta. Unidade: IFSC

    Assuntos: POLÍMEROS (MATERIAIS), SENSOR, FILMES FINOS

    Versão PublicadaAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      JOSHI, Nirav et al. UV-assisted chemiresistors made with gold-modified ZnO nanorods to detect ozone gas at room temperature. Microchimica Acta, v. 186, n. 7, p. 418-1-418-9, 2019Tradução . . Disponível em: https://doi.org/10.1007/s00604-019-3532-4. Acesso em: 04 nov. 2024.
    • APA

      Joshi, N., Silva, L. F., Shimizu, F. M., Mastelaro, V. R., M'Peko, J. -C., Lin, L., & Oliveira Junior, O. N. de. (2019). UV-assisted chemiresistors made with gold-modified ZnO nanorods to detect ozone gas at room temperature. Microchimica Acta, 186( 7), 418-1-418-9. doi:10.1007/s00604-019-3532-4
    • NLM

      Joshi N, Silva LF, Shimizu FM, Mastelaro VR, M'Peko J-C, Lin L, Oliveira Junior ON de. UV-assisted chemiresistors made with gold-modified ZnO nanorods to detect ozone gas at room temperature [Internet]. Microchimica Acta. 2019 ; 186( 7): 418-1-418-9.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-019-3532-4
    • Vancouver

      Joshi N, Silva LF, Shimizu FM, Mastelaro VR, M'Peko J-C, Lin L, Oliveira Junior ON de. UV-assisted chemiresistors made with gold-modified ZnO nanorods to detect ozone gas at room temperature [Internet]. Microchimica Acta. 2019 ; 186( 7): 418-1-418-9.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-019-3532-4
  • Fonte: Microchimica Acta. Unidade: IFSC

    Assuntos: POLÍMEROS (MATERIAIS), SENSOR, FILMES FINOS

    PrivadoAcesso à fonteDOIComo citar
    A citação é gerada automaticamente e pode não estar totalmente de acordo com as normas
    • ABNT

      JOSHI, Nirav et al. A review on chemiresistive room temperature gas sensors based on metal oxide nanostructures, graphene and 2D transition metal dichalcogenides. Microchimica Acta, v. 185, n. 4, p. 213-1-213-16, 2018Tradução . . Disponível em: https://doi.org/10.1007/s00604-018-2750-5. Acesso em: 04 nov. 2024.
    • APA

      Joshi, N., Hayasaka, T., Liu, Y., Liu, H., Oliveira Junior, O. N. de, & Lin, L. (2018). A review on chemiresistive room temperature gas sensors based on metal oxide nanostructures, graphene and 2D transition metal dichalcogenides. Microchimica Acta, 185( 4), 213-1-213-16. doi:10.1007/s00604-018-2750-5
    • NLM

      Joshi N, Hayasaka T, Liu Y, Liu H, Oliveira Junior ON de, Lin L. A review on chemiresistive room temperature gas sensors based on metal oxide nanostructures, graphene and 2D transition metal dichalcogenides [Internet]. Microchimica Acta. 2018 ; 185( 4): 213-1-213-16.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-018-2750-5
    • Vancouver

      Joshi N, Hayasaka T, Liu Y, Liu H, Oliveira Junior ON de, Lin L. A review on chemiresistive room temperature gas sensors based on metal oxide nanostructures, graphene and 2D transition metal dichalcogenides [Internet]. Microchimica Acta. 2018 ; 185( 4): 213-1-213-16.[citado 2024 nov. 04 ] Available from: https://doi.org/10.1007/s00604-018-2750-5

Biblioteca Digital de Produção Intelectual da Universidade de São Paulo     2012 - 2024